... ... @@ -21,6 +21,7 @@
21 21  1. Firmware version for below instruction:**[[(% style="color:purple" %)Since LG02_LG08~~-~~-build-v5.4.1593400722-20200629-1120>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_Gateway/LPS8/Firmware/Release/]](%%)**
22 22  
23 23  
24 +
24 24  = 2. How it works =
25 25  
26 26  
... ... @@ -44,8 +44,10 @@
44 44  
45 45  We need to input above keys in LG308 and enable ABP decryption.
46 46  
48 +
47 47  [[image:image-20220527161119-1.png]]
48 48  
51 +
49 49  Input the ABP keys in LG308
50 50  
51 51  
... ... @@ -55,14 +55,18 @@
55 55  Now when this End Node (Dev Addr=2602111D) send a uplink packet. When this packet arrive LG308, LG308 will decode it and put the decode data on the file /var/iot/channels/2602111D . So we have this data for further process with other applications in LG308.
56 56  
57 57  (((
58 -We can see the log of LG308 to know this packet arrive
61 +We can see the log of LG308 to know this packet arrive.
62 +
63 +
59 59  )))
60 60  
61 61  [[image:image-20220527161149-2.png]]
62 62  
68 +
63 63  LG308 log by "(% style="color:red" %)**logread -f**" (%%)command
64 64  
65 65  
72 +
66 66  The data of End Node is stored in the file /var/iot/channels/2602111D. We can use hexdump command to check it.
67 67  
68 68  (% class="box" %)
... ... @@ -87,6 +87,7 @@
87 87  000001c
88 88  )))
89 89  
97 +
90 90  (% class="box" %)
91 91  (((
92 92  (% style="color:red" %)**Notice 2**(%%): The upstream payload length should match the LoRaWAN length requirement (max length depends on Frequency and DR), otherwise the gateway can't decode the payload.
... ... @@ -132,7 +132,6 @@
132 132  Above scripts are store in /etc/lora/decoder/. User can put their scripts here and select it in the UI.
133 133  
134 134  
135 -
136 136  === 2.2.2 How to Decode My End Node ===
137 137  
138 138  
... ... @@ -171,10 +171,11 @@
171 171  
172 172  (% style="color:#037691" %)**dev_addr,imme/time,txt/hex,payload**
173 173  
174 -Since fimware > Dragino-v2 lgw-5.4.1608518541 . Support more option
175 175  
176 -(% style="color:#037691" %)**dev_addr,imme/time,txt/hex,payload,txpw,txbw,SF,frequency,rxwindow**
182 +Since fimware > [[Dragino lgw~~-~~-build-v5.4.1668567157>>https://www.dragino.com/downloads/index.php?dir=LoRa_Gateway/LG308-LG301/Firmware/Release/]] . Support more option
177 177  
184 +(% style="color:#037691" %)**dev_addr,imme/time,txt/hex,payload,txpw,txbw,SF,frequency,rxwindow,Fport**
185 +
178 178  * **dev_addr:** Inptu the device address
179 179  * **imme/time:**
180 180  ** imme: send downstream immediately,For Class C end node.
... ... @@ -192,20 +192,15 @@
192 192  * **SF:** Spreading Factor : SF7/SF8/SF9/SF10/SF11/SF12
193 193  * **Frequency:** Transmit Frequency: example: 923300000
194 194  * **rxwindow:** transmit on Rx1Window or Rx2Window.
203 +* **Fport: **Transmit port,example:8
195 195  
196 -
197 -
198 -
199 199  (% style="color:blue" %)**Completely exmaple:**
200 200  
201 201  * **Old version:** echo 018193F4,imme,hex,0101 > /var/iot/push/test
202 -* **New version:** echo 018193F4,imme,hex,0101,20,1,SF12,923300000,2 > /var/iot/push/test
208 +* **New version:** echo 018193F4,imme,hex,0101,20,1,SF12,923300000,2,8 > /var/iot/push/test
203 203  
210 +(% style="color:#037691" %)**Downstream Frequency:**
204 204  
205 -
206 -
207 -(% style="color:#037691" %)**Downstream Frequency**
208 -
209 209  The LG308 will use the RX2 window info to send the downstream payload, use the default LoRaWAN settings, as below:
210 210  
211 211  * EU868: 869.525Mhz, DR0(SF12BW125)
... ... @@ -217,9 +217,6 @@
217 217  * IN865: 866.55Mhz, SF10 BW125
218 218  * RU864: 869.1Mhz, SF12 BW125
219 219  
220 -
221 -
222 -
223 223  (% style="color:#037691" %)**Examples:**
224 224  
225 225  (% class="box" %)
... ... @@ -226,25 +226,19 @@
226 226  (((
227 227  we can use echo command to create files in LG308 for downstream.
228 228  root@dragino-1d25dc:~~# echo 2602111D,time,hex,12345678 > /var/iot/push/test
229 -)))
230 230  
231 -(% class="box" %)
232 -(((
230 +
233 233  **1)** From logread -f of gateway, we can see it has been added as pedning.
234 234  lora_pkt_fwd[4286]: INFO~~ [DNLK]Looking file : test
235 235  lora_pkt_fwd[4286]: INFO~~ [DNLK]devaddr:2602111D, txmode:time, pdfm:hex, size:4, payload1:4Vx,payload_hex:77C1BB90
236 236  lora_pkt_fwd[4286]: INFO~~ [DNLK] DNLINK PENDING!(1 elems).
237 -)))
238 238  
239 -(% class="box" %)
240 -(((
236 +
241 241  **2)** When there is an upstrea from end node, this downstream will be sent and shows:
242 242  lora_pkt_fwd[4286]: INFO: tx_start_delay=1497 (1497.000000) - (1497, bw_delay=0.000000, notch_delay=0.000000)
243 243  lora_pkt_fwd[4286]: [LGWSEND]lgw_send done: count_us=3537314420, freq=923300000, size=17
244 -)))
245 245  
246 -(% class="box" %)
247 -(((
241 +
248 248  **3)** and the end node will got:
249 249  [5764825]~*~*~*~** UpLinkCounter= 98 ~*~*~*~**
250 250  [5764827]TX on freq 905300000 Hz at DR 0
... ... @@ -257,10 +257,8 @@
257 257  Rssi= -41
258 258  Receive data
259 259  (% style="color:#037691" %)**2:12345678**  (%%) ~-~-> Hex
260 -)))
261 261  
262 -(% class="box" %)
263 -(((
255 +
264 264  **4) **If we use the command "echo 2602111D,time,txt,12345678 > /var/iot/push/test" for downstream, the end node will got:
265 265  [5955877]~*~*~*~** UpLinkCounter= 102 ~*~*~*~**
266 266  [5955879]TX on freq 904100000 Hz at DR 0
... ... @@ -319,33 +319,42 @@
319 319  #  whether the Device 2 has been changed.//
320 320  )))
321 321  
322 -**~1. Input keys**
323 323  
315 +(% style="color:blue" %)**1. Input keys**
316 +
317 +
324 324  [[image:image-20220527162450-3.png]]
325 325  
326 326  Input Keys in LPS8
327 327  
328 328  
329 -**2. Make sure the LPS8 and LT use the same frequency bands, choose EU868 in this test.**
330 330  
331 -**3. Choose Built-in server**
324 +(% style="color:blue" %)**2. Make sure the LPS8 and LT use the same frequency bands, choose EU868 in this test.**
332 332  
326 +
327 +(% style="color:blue" %)**3. Choose Built-in server**
328 +
329 +
333 333  [[image:image-20220527162518-4.png]]
334 334  
335 335  Choose Built-in server
336 336  
337 337  
338 -**4. Run the script.**
339 339  
340 -[[image:image-20220527162552-5.png]]
336 +(% style="color:blue" %)**4. Run the script.**
341 341  
338 +
339 +[[image:image-20220722115213-2.png]]
340 +
342 342  Run the script
343 343  
344 344  
345 -**5. Output:**
346 346  
347 -[[image:image-20220527162619-6.png]]
345 +(% style="color:blue" %)**5. Output:**
348 348  
347 +
348 +[[image:image-20220722115133-1.png]]
349 +
349 349  Output from LPS8
350 350  
351 351  
... ... @@ -374,8 +374,9 @@
374 374  
375 375  
376 376  
377 -**run socket tool in PC**
378 +(% style="color:blue" %)**run socket tool in PC**
378 378  
380 +
379 379  [[image:image-20220527163028-9.png]]
380 380  
381 381  
... ... @@ -383,8 +383,9 @@
383 383  
384 384  
385 385  
386 -**Input Server address and port**
388 +(% style="color:blue" %)**Input Server address and port**
387 387  
390 +
388 388  [[image:image-20220527163106-10.png]]
389 389  
390 390  Input Server address and port
... ... @@ -391,8 +391,9 @@
391 391  
392 392  
393 393  
394 -**See value receive in socket tool:**
397 +(% style="color:blue" %)**See value receive in socket tool:**
395 395  
399 +
396 396  [[image:image-20220527163144-11.png]]
397 397  
398 398  value receive in socket tool
image-20220722115133-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +35.1 KB
Content
image-20220722115213-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +27.7 KB
Content
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0