<
From version < 16.3 >
edited by Xiaoling
on 2022/07/22 11:41
To version < 16.9 >
edited by Xiaoling
on 2022/07/22 11:47
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -21,6 +21,8 @@
21 21  1. Firmware version for below instruction:**[[(% style="color:purple" %)Since LG02_LG08~~-~~-build-v5.4.1593400722-20200629-1120>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_Gateway/LPS8/Firmware/Release/]](%%)**
22 22  
23 23  
24 +
25 +
24 24  = 2. How it works =
25 25  
26 26  
... ... @@ -77,6 +77,9 @@
77 77  * **SNR**: 3030 3030 3030 3546 = 0x0000 005F = 95, need to divide 10 so SNR is 9.5
78 78  * **Payload**: 0xcc0c 0b63 0266 017f ff7f ff00
79 79  
82 +
83 +
84 +
80 80  (% class="box" %)
81 81  (((
82 82  (% style="color:red" %)**Notice 1**(%%): The data file stored in LG308 for the end node is bin file. If the end node sends ASCII string to gateway, the output will as below:
... ... @@ -162,6 +162,8 @@
162 162  
163 163  
164 164  
170 +
171 +
165 165  == 2.2 Downstream ==
166 166  
167 167  
... ... @@ -194,8 +194,6 @@
194 194  * **rxwindow:** transmit on Rx1Window or Rx2Window.
195 195  
196 196  
197 -
198 -
199 199  (% style="color:blue" %)**Completely exmaple:**
200 200  
201 201  * **Old version:** echo 018193F4,imme,hex,0101 > /var/iot/push/test
... ... @@ -202,8 +202,6 @@
202 202  * **New version:** echo 018193F4,imme,hex,0101,20,1,SF12,923300000,2 > /var/iot/push/test
203 203  
204 204  
205 -
206 -
207 207  (% style="color:#037691" %)**Downstream Frequency**
208 208  
209 209  The LG308 will use the RX2 window info to send the downstream payload, use the default LoRaWAN settings, as below:
... ... @@ -218,8 +218,6 @@
218 218  * RU864: 869.1Mhz, SF12 BW125
219 219  
220 220  
221 -
222 -
223 223  (% style="color:#037691" %)**Examples:**
224 224  
225 225  (% class="box" %)
... ... @@ -226,25 +226,19 @@
226 226  (((
227 227  we can use echo command to create files in LG308 for downstream.
228 228  root@dragino-1d25dc:~~# echo 2602111D,time,hex,12345678 > /var/iot/push/test
229 -)))
230 230  
231 -(% class="box" %)
232 -(((
231 +
233 233  **1)** From logread -f of gateway, we can see it has been added as pedning.
234 234  lora_pkt_fwd[4286]: INFO~~ [DNLK]Looking file : test
235 235  lora_pkt_fwd[4286]: INFO~~ [DNLK]devaddr:2602111D, txmode:time, pdfm:hex, size:4, payload1:4Vx,payload_hex:77C1BB90
236 236  lora_pkt_fwd[4286]: INFO~~ [DNLK] DNLINK PENDING!(1 elems).
237 -)))
238 238  
239 -(% class="box" %)
240 -(((
237 +
241 241  **2)** When there is an upstrea from end node, this downstream will be sent and shows:
242 242  lora_pkt_fwd[4286]: INFO: tx_start_delay=1497 (1497.000000) - (1497, bw_delay=0.000000, notch_delay=0.000000)
243 243  lora_pkt_fwd[4286]: [LGWSEND]lgw_send done: count_us=3537314420, freq=923300000, size=17
244 -)))
245 245  
246 -(% class="box" %)
247 -(((
242 +
248 248  **3)** and the end node will got:
249 249  [5764825]~*~*~*~** UpLinkCounter= 98 ~*~*~*~**
250 250  [5764827]TX on freq 905300000 Hz at DR 0
... ... @@ -257,10 +257,8 @@
257 257  Rssi= -41
258 258  Receive data
259 259  (% style="color:#037691" %)**2:12345678**  (%%) ~-~-> Hex
260 -)))
261 261  
262 -(% class="box" %)
263 -(((
256 +
264 264  **4) **If we use the command "echo 2602111D,time,txt,12345678 > /var/iot/push/test" for downstream, the end node will got:
265 265  [5955877]~*~*~*~** UpLinkCounter= 102 ~*~*~*~**
266 266  [5955879]TX on freq 904100000 Hz at DR 0
... ... @@ -319,6 +319,7 @@
319 319  #  whether the Device 2 has been changed.//
320 320  )))
321 321  
315 +
322 322  **~1. Input keys**
323 323  
324 324  [[image:image-20220527162450-3.png]]
... ... @@ -328,6 +328,7 @@
328 328  
329 329  **2. Make sure the LPS8 and LT use the same frequency bands, choose EU868 in this test.**
330 330  
325 +
331 331  **3. Choose Built-in server**
332 332  
333 333  [[image:image-20220527162518-4.png]]
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0