<
From version < 16.3 >
edited by Xiaoling
on 2022/07/22 11:41
To version < 16.4 >
edited by Xiaoling
on 2022/07/22 11:45
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -20,7 +20,6 @@
20 20  1. LoRaWAN Gateway model: [[LPS8>>url:http://www.dragino.com/products/lora-lorawan-gateway/item/148-lps8.html]], [[LG308>>url:http://www.dragino.com/products/lora-lorawan-gateway/item/140-lg308.html]], [[DLOS8>>url:http://www.dragino.com/products/lora-lorawan-gateway/item/160-dlos8.html]] ,[[LIG16>>url:http://www.dragino.com/products/lora-lorawan-gateway/item/171-lig16.html]]
21 21  1. Firmware version for below instruction:**[[(% style="color:purple" %)Since LG02_LG08~~-~~-build-v5.4.1593400722-20200629-1120>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_Gateway/LPS8/Firmware/Release/]](%%)**
22 22  
23 -
24 24  = 2. How it works =
25 25  
26 26  
... ... @@ -161,7 +161,6 @@
161 161  * User can use other language ,not limited to Lua, just make sure the return is what you want to send.
162 162  
163 163  
164 -
165 165  == 2.2 Downstream ==
166 166  
167 167  
... ... @@ -195,7 +195,6 @@
195 195  
196 196  
197 197  
198 -
199 199  (% style="color:blue" %)**Completely exmaple:**
200 200  
201 201  * **Old version:** echo 018193F4,imme,hex,0101 > /var/iot/push/test
... ... @@ -203,7 +203,6 @@
203 203  
204 204  
205 205  
206 -
207 207  (% style="color:#037691" %)**Downstream Frequency**
208 208  
209 209  The LG308 will use the RX2 window info to send the downstream payload, use the default LoRaWAN settings, as below:
... ... @@ -219,7 +219,6 @@
219 219  
220 220  
221 221  
222 -
223 223  (% style="color:#037691" %)**Examples:**
224 224  
225 225  (% class="box" %)
... ... @@ -226,25 +226,19 @@
226 226  (((
227 227  we can use echo command to create files in LG308 for downstream.
228 228  root@dragino-1d25dc:~~# echo 2602111D,time,hex,12345678 > /var/iot/push/test
229 -)))
230 230  
231 -(% class="box" %)
232 -(((
225 +
233 233  **1)** From logread -f of gateway, we can see it has been added as pedning.
234 234  lora_pkt_fwd[4286]: INFO~~ [DNLK]Looking file : test
235 235  lora_pkt_fwd[4286]: INFO~~ [DNLK]devaddr:2602111D, txmode:time, pdfm:hex, size:4, payload1:4Vx,payload_hex:77C1BB90
236 236  lora_pkt_fwd[4286]: INFO~~ [DNLK] DNLINK PENDING!(1 elems).
237 -)))
238 238  
239 -(% class="box" %)
240 -(((
231 +
241 241  **2)** When there is an upstrea from end node, this downstream will be sent and shows:
242 242  lora_pkt_fwd[4286]: INFO: tx_start_delay=1497 (1497.000000) - (1497, bw_delay=0.000000, notch_delay=0.000000)
243 243  lora_pkt_fwd[4286]: [LGWSEND]lgw_send done: count_us=3537314420, freq=923300000, size=17
244 -)))
245 245  
246 -(% class="box" %)
247 -(((
236 +
248 248  **3)** and the end node will got:
249 249  [5764825]~*~*~*~** UpLinkCounter= 98 ~*~*~*~**
250 250  [5764827]TX on freq 905300000 Hz at DR 0
... ... @@ -257,10 +257,8 @@
257 257  Rssi= -41
258 258  Receive data
259 259  (% style="color:#037691" %)**2:12345678**  (%%) ~-~-> Hex
260 -)))
261 261  
262 -(% class="box" %)
263 -(((
250 +
264 264  **4) **If we use the command "echo 2602111D,time,txt,12345678 > /var/iot/push/test" for downstream, the end node will got:
265 265  [5955877]~*~*~*~** UpLinkCounter= 102 ~*~*~*~**
266 266  [5955879]TX on freq 904100000 Hz at DR 0
... ... @@ -273,6 +273,8 @@
273 273  Rssi= -37
274 274  Receive data
275 275  (% style="color:#037691" %)**2:3132333435363738**(%%) ~-~-> ASCII string "12345678"
263 +
264 +
276 276  )))
277 277  
278 278  
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0