Last modified by Xiaoling on 2023/04/20 18:14
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -20,7 +20,6 @@ 20 20 1. LoRaWAN Gateway model: [[LPS8>>url:http://www.dragino.com/products/lora-lorawan-gateway/item/148-lps8.html]], [[LG308>>url:http://www.dragino.com/products/lora-lorawan-gateway/item/140-lg308.html]], [[DLOS8>>url:http://www.dragino.com/products/lora-lorawan-gateway/item/160-dlos8.html]] ,[[LIG16>>url:http://www.dragino.com/products/lora-lorawan-gateway/item/171-lig16.html]] 21 21 1. Firmware version for below instruction:**[[(% style="color:purple" %)Since LG02_LG08~~-~~-build-v5.4.1593400722-20200629-1120>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_Gateway/LPS8/Firmware/Release/]](%%)** 22 22 23 - 24 24 = 2. How it works = 25 25 26 26 ... ... @@ -161,7 +161,6 @@ 161 161 * User can use other language ,not limited to Lua, just make sure the return is what you want to send. 162 162 163 163 164 - 165 165 == 2.2 Downstream == 166 166 167 167 ... ... @@ -195,7 +195,6 @@ 195 195 196 196 197 197 198 - 199 199 (% style="color:blue" %)**Completely exmaple:** 200 200 201 201 * **Old version:** echo 018193F4,imme,hex,0101 > /var/iot/push/test ... ... @@ -203,7 +203,6 @@ 203 203 204 204 205 205 206 - 207 207 (% style="color:#037691" %)**Downstream Frequency** 208 208 209 209 The LG308 will use the RX2 window info to send the downstream payload, use the default LoRaWAN settings, as below: ... ... @@ -219,7 +219,6 @@ 219 219 220 220 221 221 222 - 223 223 (% style="color:#037691" %)**Examples:** 224 224 225 225 (% class="box" %) ... ... @@ -226,25 +226,19 @@ 226 226 ((( 227 227 we can use echo command to create files in LG308 for downstream. 228 228 root@dragino-1d25dc:~~# echo 2602111D,time,hex,12345678 > /var/iot/push/test 229 -))) 230 230 231 -(% class="box" %) 232 -((( 225 + 233 233 **1)** From logread -f of gateway, we can see it has been added as pedning. 234 234 lora_pkt_fwd[4286]: INFO~~ [DNLK]Looking file : test 235 235 lora_pkt_fwd[4286]: INFO~~ [DNLK]devaddr:2602111D, txmode:time, pdfm:hex, size:4, payload1:4Vx,payload_hex:77C1BB90 236 236 lora_pkt_fwd[4286]: INFO~~ [DNLK] DNLINK PENDING!(1 elems). 237 -))) 238 238 239 -(% class="box" %) 240 -((( 231 + 241 241 **2)** When there is an upstrea from end node, this downstream will be sent and shows: 242 242 lora_pkt_fwd[4286]: INFO: tx_start_delay=1497 (1497.000000) - (1497, bw_delay=0.000000, notch_delay=0.000000) 243 243 lora_pkt_fwd[4286]: [LGWSEND]lgw_send done: count_us=3537314420, freq=923300000, size=17 244 -))) 245 245 246 -(% class="box" %) 247 -((( 236 + 248 248 **3)** and the end node will got: 249 249 [5764825]~*~*~*~** UpLinkCounter= 98 ~*~*~*~** 250 250 [5764827]TX on freq 905300000 Hz at DR 0 ... ... @@ -257,10 +257,8 @@ 257 257 Rssi= -41 258 258 Receive data 259 259 (% style="color:#037691" %)**2:12345678** (%%) ~-~-> Hex 260 -))) 261 261 262 -(% class="box" %) 263 -((( 250 + 264 264 **4) **If we use the command "echo 2602111D,time,txt,12345678 > /var/iot/push/test" for downstream, the end node will got: 265 265 [5955877]~*~*~*~** UpLinkCounter= 102 ~*~*~*~** 266 266 [5955879]TX on freq 904100000 Hz at DR 0 ... ... @@ -273,6 +273,8 @@ 273 273 Rssi= -37 274 274 Receive data 275 275 (% style="color:#037691" %)**2:3132333435363738**(%%) ~-~-> ASCII string "12345678" 263 + 264 + 276 276 ))) 277 277 278 278