Last modified by Xiaoling on 2023/04/20 18:14
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -21,6 +21,7 @@ 21 21 1. Firmware version for below instruction:**[[(% style="color:purple" %)Since LG02_LG08~~-~~-build-v5.4.1593400722-20200629-1120>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_Gateway/LPS8/Firmware/Release/]](%%)** 22 22 23 23 24 + 24 24 = 2. How it works = 25 25 26 26 ... ... @@ -77,6 +77,8 @@ 77 77 * **SNR**: 3030 3030 3030 3546 = 0x0000 005F = 95, need to divide 10 so SNR is 9.5 78 78 * **Payload**: 0xcc0c 0b63 0266 017f ff7f ff00 79 79 81 + 82 + 80 80 (% class="box" %) 81 81 ((( 82 82 (% style="color:red" %)**Notice 1**(%%): The data file stored in LG308 for the end node is bin file. If the end node sends ASCII string to gateway, the output will as below: ... ... @@ -162,6 +162,7 @@ 162 162 163 163 164 164 168 + 165 165 == 2.2 Downstream == 166 166 167 167 ... ... @@ -193,11 +193,17 @@ 193 193 * **Frequency:** Transmit Frequency: example: 923300000 194 194 * **rxwindow:** transmit on Rx1Window or Rx2Window. 195 195 200 + 201 + 202 + 196 196 (% style="color:blue" %)**Completely exmaple:** 197 197 198 198 * **Old version:** echo 018193F4,imme,hex,0101 > /var/iot/push/test 199 199 * **New version:** echo 018193F4,imme,hex,0101,20,1,SF12,923300000,2 > /var/iot/push/test 200 200 208 + 209 + 210 + 201 201 (% style="color:#037691" %)**Downstream Frequency** 202 202 203 203 The LG308 will use the RX2 window info to send the downstream payload, use the default LoRaWAN settings, as below: ... ... @@ -211,6 +211,9 @@ 211 211 * IN865: 866.55Mhz, SF10 BW125 212 212 * RU864: 869.1Mhz, SF12 BW125 213 213 224 + 225 + 226 + 214 214 (% style="color:#037691" %)**Examples:** 215 215 216 216 (% class="box" %) ... ... @@ -217,25 +217,19 @@ 217 217 ((( 218 218 we can use echo command to create files in LG308 for downstream. 219 219 root@dragino-1d25dc:~~# echo 2602111D,time,hex,12345678 > /var/iot/push/test 220 -))) 221 221 222 -(% class="box" %) 223 -((( 234 + 224 224 **1)** From logread -f of gateway, we can see it has been added as pedning. 225 225 lora_pkt_fwd[4286]: INFO~~ [DNLK]Looking file : test 226 226 lora_pkt_fwd[4286]: INFO~~ [DNLK]devaddr:2602111D, txmode:time, pdfm:hex, size:4, payload1:4Vx,payload_hex:77C1BB90 227 227 lora_pkt_fwd[4286]: INFO~~ [DNLK] DNLINK PENDING!(1 elems). 228 -))) 229 229 230 -(% class="box" %) 231 -((( 240 + 232 232 **2)** When there is an upstrea from end node, this downstream will be sent and shows: 233 233 lora_pkt_fwd[4286]: INFO: tx_start_delay=1497 (1497.000000) - (1497, bw_delay=0.000000, notch_delay=0.000000) 234 234 lora_pkt_fwd[4286]: [LGWSEND]lgw_send done: count_us=3537314420, freq=923300000, size=17 235 -))) 236 236 237 -(% class="box" %) 238 -((( 245 + 239 239 **3)** and the end node will got: 240 240 [5764825]~*~*~*~** UpLinkCounter= 98 ~*~*~*~** 241 241 [5764827]TX on freq 905300000 Hz at DR 0 ... ... @@ -248,10 +248,8 @@ 248 248 Rssi= -41 249 249 Receive data 250 250 (% style="color:#037691" %)**2:12345678** (%%) ~-~-> Hex 251 -))) 252 252 253 -(% class="box" %) 254 -((( 259 + 255 255 **4) **If we use the command "echo 2602111D,time,txt,12345678 > /var/iot/push/test" for downstream, the end node will got: 256 256 [5955877]~*~*~*~** UpLinkCounter= 102 ~*~*~*~** 257 257 [5955879]TX on freq 904100000 Hz at DR 0 ... ... @@ -310,6 +310,7 @@ 310 310 # whether the Device 2 has been changed.// 311 311 ))) 312 312 318 + 313 313 **~1. Input keys** 314 314 315 315 [[image:image-20220527162450-3.png]] ... ... @@ -319,6 +319,7 @@ 319 319 320 320 **2. Make sure the LPS8 and LT use the same frequency bands, choose EU868 in this test.** 321 321 328 + 322 322 **3. Choose Built-in server** 323 323 324 324 [[image:image-20220527162518-4.png]]
- image-20220722115133-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +35.1 KB - Content