Last modified by Xiaoling on 2023/04/20 18:14
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 2 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -39,7 +39,7 @@ 39 39 40 40 We need to input above keys in LG308 and enable ABP decryption. 41 41 42 -[[image: https://wiki.dragino.com/images/thumb/5/55/LG308_MQTT_1.png/600px-LG308_MQTT_1.png||height="329" width="600"]]42 +[[image:image-20220527161119-1.png]] 43 43 44 44 Input the ABP keys in LG308 45 45 ... ... @@ -52,7 +52,7 @@ 52 52 We can see the log of LG308 to know this packet arrive 53 53 ))) 54 54 55 -[[image: https://wiki.dragino.com/images/thumb/1/16/ABP_DECODE_2.png/600px-ABP_DECODE_2.png||height="205" width="600"]]55 +[[image:image-20220527161149-2.png]] 56 56 57 57 LG308 log by "logread -f" command 58 58 ... ... @@ -62,8 +62,8 @@ 62 62 (% class="box" %) 63 63 ((( 64 64 root@dragino-1d25dc:~~# hexdump /var/iot/channels/2602111D 65 -0000000 (% class="mark" %)**4646 4646 4646 3946 3030 3030 3030 3546**(%%) ~-~-> Got RSSI and SNR66 -0000010 (% class="mark" %)**cc0c 0b63 0266 017f ff7f ff00 **(%%) ~-~-> Payload65 +0000000 (% style="color:#037691" %)**4646 4646 4646 3946 3030 3030 3030 3546**(%%) ~-~-> Got RSSI and SNR 66 +0000010 (% style="color:#037691" %)**cc0c 0b63 0266 017f ff7f ff00 **(%%) ~-~-> Payload 67 67 000001c 68 68 ))) 69 69 ... ... @@ -73,8 +73,8 @@ 73 73 74 74 (% class="box" %) 75 75 ((( 76 -(% class="mark" %)**Notice 1**(%%): The data file stored in LG308 for the end node is bin file. If the end node sends ASCII string to gateway, the output will as below:77 -in LGT92, use **AT+SEND=12 **:hello world to send ASCII string76 +(% style="color:red" %)**Notice 1**(%%): The data file stored in LG308 for the end node is bin file. If the end node sends ASCII string to gateway, the output will as below: 77 +in LGT92, use (% style="color:#037691" %)**AT+SEND=12:hello world** (%%)to send ASCII string 78 78 root@dragino-1d25dc:~~# hexdump /var/iot/channels/2602111D 79 79 0000000 4646 4646 4646 3946 3030 3030 3030 3546 80 80 0000010 6865 6c6c 6f20 776f 726c 6400 ~-~-> Got ASCII code "hello world" ... ... @@ -83,12 +83,13 @@ 83 83 84 84 (% class="box" %) 85 85 ((( 86 -(% class="mark" %)**Notice 2**(%%): The upstream payload length should match the LoRaWAN length requirement (max length depends on Frequency and DR), otherwise the gateway can't decode the payload.86 +(% style="color:#037691" %)**Notice 2**(%%): The upstream payload length should match the LoRaWAN length requirement (max length depends on Frequency and DR), otherwise the gateway can't decode the payload. 87 87 ))) 88 88 89 + 89 89 === 2.2.1 Decode Method === 90 90 91 -The decode methods: **ASCII String, Decode_LHT65** doesn't affect how the sensor data is stored, they are to define how should the sensor data to be sent. 92 +The decode methods: (% style="color:#037691" %)**ASCII String, Decode_LHT65**(%%) doesn't affect how the sensor data is stored, they are to define how should the sensor data to be sent. 92 92 93 93 For example we have a LHT65 , works in ABP mode and gateway successful get the data, which are: 94 94 ... ... @@ -106,7 +106,7 @@ 106 106 ((( 107 107 Sun Sep 27 04:33:16 2020 user.notice root: [IoT.MQTT]:pub_topic[-t]: dragino-1baf44/01826108/data 108 108 Sun Sep 27 04:33:16 2020 user.notice root: [IoT.MQTT]:decoder: ASCII 109 -Sun Sep 27 04:33:16 2020 user.notice root: [IoT.MQTT]:mqtt_data[-m]: ffffffe700000048ccd17fff7fff017fff7fff00 110 +Sun Sep 27 04:33:16 2020 user.notice root: [IoT.MQTT]:mqtt_data[-m]: (% style="color:#037691" %)**ffffffe700000048ccd17fff7fff017fff7fff00** 110 110 ))) 111 111 112 112 If we choose Decode_LHT65, the MQTT process will send out with mqtt-data ... ... @@ -115,8 +115,8 @@ 115 115 ((( 116 116 Sun Sep 27 04:36:45 2020 user.notice root: [IoT.MQTT]:pub_topic[-t]: dragino-1baf44/01826108/data 117 117 Sun Sep 27 04:36:45 2020 user.notice root: [IoT.MQTT]:decoder: Dragino_LHT65 118 -Sun Sep 27 04:36:45 2020 user.notice root: [IoT.MQTT]:mqtt_data[-m]: {"Hum_SHT":32.7,"BatV":3.281,"TempC_DS":32.9, 119 -"EXT":"Temperature Sensor","RSSI":-24,"TempC_SHT":85.0,"SNR":8.2,"ext_sensor":0} 119 +Sun Sep 27 04:36:45 2020 user.notice root: [IoT.MQTT]:mqtt_data[-m]:** (% style="color:#037691" %){"Hum_SHT":32.7,"BatV":3.281,"TempC_DS":32.9, 120 +"EXT":"Temperature Sensor","RSSI":-24,"TempC_SHT":85.0,"SNR":8.2,"ext_sensor":0}(%%)** 120 120 ))) 121 121 122 122 Above scripts are store in /etc/lora/decoder/. User can put their scripts here and select it in the UI. ... ... @@ -144,6 +144,8 @@ 144 144 * the last line return is what will be used for MQTT 145 145 * User can use other language ,not limited to Lua, just make sure the return is what you want to send. 146 146 148 + 149 + 147 147 == 2.2 Downstream == 148 148 149 149 In LG308, we can create a file in the directory /var/iot/push for downstream purpose. We recommend using each command to generate this file. This file will be used for transmission and auto-deleted after used ... ... @@ -150,11 +150,11 @@ 150 150 151 151 The file should use below format: 152 152 153 -(% class="mark" %)**dev_addr,imme/time,txt/hex,payload**156 +(% style="color:#037691" %)**dev_addr,imme/time,txt/hex,payload** 154 154 155 155 Since fimware > Dragino-v2 lgw-5.4.1608518541 . Support more option 156 156 157 -(% class="mark" %)**dev_addr,imme/time,txt/hex,payload,txpw,txbw,SF,frequency,rxwindow**160 +(% style="color:#037691" %)**dev_addr,imme/time,txt/hex,payload,txpw,txbw,SF,frequency,rxwindow** 158 158 159 159 * dev_addr: Inptu the device address 160 160 * imme/time: ... ... @@ -179,8 +179,9 @@ 179 179 * Old version: echo 018193F4,imme,hex,0101 > /var/iot/push/test 180 180 * New version: echo 018193F4,imme,hex,0101,20,1,SF12,923300000,2 > /var/iot/push/test 181 181 182 -(% class="mark" %)**Downstream Frequency** 183 183 186 +(% style="color:#037691" %)**Downstream Frequency** 187 + 184 184 The LG308 will use the RX2 window info to send the downstream payload, use the default LoRaWAN settings, as below: 185 185 186 186 * EU868: 869.525Mhz, DR0(SF12BW125) ... ... @@ -192,8 +192,9 @@ 192 192 * IN865: 866.55Mhz, SF10 BW125 193 193 * RU864: 869.1Mhz, SF12 BW125 194 194 195 -(% class="mark" %)**Examples:** 196 196 200 +(% style="color:#037691" %)**Examples:** 201 + 197 197 (% class="box" %) 198 198 ((( 199 199 we can use echo command to create files in LG308 for downstream. ... ... @@ -228,7 +228,7 @@ 228 228 [5767501]rxDone 229 229 Rssi= -41 230 230 Receive data 231 -2:12345678 236 +(% style="color:#037691" %)**2:12345678** (%%) ~-~-> Hex 232 232 ))) 233 233 234 234 (% class="box" %) ... ... @@ -244,9 +244,10 @@ 244 244 [5958595]rxDone 245 245 Rssi= -37 246 246 Receive data 247 -2:3132333435363738 ~-~-> ASCII string "12345678" 252 +(% style="color:#037691" %)**2:3132333435363738**(%%) ~-~-> ASCII string "12345678" 248 248 ))) 249 249 255 + 250 250 = 3. Example 1: Communicate with LT-22222-L = 251 251 252 252 Script can be download from: [[Example Script 1>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_Gateway/LPS8/Firmware/customized_script/&file=talk_to_lt-22222-l_v0.1.sh]]
- image-20220527161119-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +128.8 KB - Content
- image-20220527161149-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +103.9 KB - Content