... ... @@ -23,6 +23,7 @@
23 23  
24 24  (% style="color:#037691" %)**Video Instruction**(%%): **[[https:~~/~~/youtu.be/ZBjXwmp7rwM>>url:https://youtu.be/ZBjXwmp7rwM]]**
25 25  
26 +
26 26  Assume we have the LoRaWAN tracker LGT92 which works in ABP mode and US915 band. It has below keys:
27 27  
28 28  (% class="box infomessage" %)
... ... @@ -38,7 +38,7 @@
38 38  
39 39  We need to input above keys in LG308 and enable ABP decryption.
40 40  
41 -[[image:https://wiki.dragino.com/images/thumb/5/55/LG308_MQTT_1.png/600px-LG308_MQTT_1.png||height="329" width="600"]]
42 +[[image:image-20220527161119-1.png]]
42 42  
43 43  Input the ABP keys in LG308
44 44  
... ... @@ -51,7 +51,7 @@
51 51  We can see the log of LG308 to know this packet arrive
52 52  )))
53 53  
54 -[[image:https://wiki.dragino.com/images/thumb/1/16/ABP_DECODE_2.png/600px-ABP_DECODE_2.png||height="205" width="600"]]
55 +[[image:image-20220527161149-2.png]]
55 55  
56 56  LG308 log by "logread -f" command
57 57  
... ... @@ -61,8 +61,8 @@
61 61  (% class="box" %)
62 62  (((
63 63  root@dragino-1d25dc:~~# hexdump /var/iot/channels/2602111D
64 -0000000 (% class="mark" %)**4646 4646 4646 3946 3030 3030 3030 3546**(%%)      ~-~-> Got RSSI and SNR    
65 -0000010 (% class="mark" %)**cc0c 0b63 0266 017f ff7f ff00 **(%%) ~-~-> Payload
65 +0000000 (% style="color:#037691" %)**4646 4646 4646 3946 3030 3030 3030 3546**(%%)      ~-~-> Got RSSI and SNR    
66 +0000010 (% style="color:#037691" %)**cc0c 0b63 0266 017f ff7f ff00 **(%%) ~-~-> Payload
66 66  000001c
67 67  )))
68 68  
... ... @@ -72,8 +72,8 @@
72 72  
73 73  (% class="box" %)
74 74  (((
75 -(% class="mark" %)**Notice 1**(%%): The data file stored in LG308 for the end node is bin file. If the end node sends ASCII string to gateway, the output will as below:
76 -in LGT92, use **AT+SEND=12**:hello world to send ASCII string
76 +(% style="color:red" %)**Notice 1**(%%): The data file stored in LG308 for the end node is bin file. If the end node sends ASCII string to gateway, the output will as below:
77 +in LGT92, use (% style="color:#037691" %)**AT+SEND=12:hello world** (%%)to send ASCII string
77 77  root@dragino-1d25dc:~~# hexdump /var/iot/channels/2602111D
78 78  0000000 4646 4646 4646 3946 3030 3030 3030 3546
79 79  0000010 6865 6c6c 6f20 776f 726c 6400      ~-~-> Got ASCII code "hello world"    
... ... @@ -82,12 +82,13 @@
82 82  
83 83  (% class="box" %)
84 84  (((
85 -(% class="mark" %)**Notice 2**(%%): The upstream payload length should match the LoRaWAN length requirement (max length depends on Frequency and DR), otherwise the gateway can't decode the payload.
86 +(% style="color:#037691" %)**Notice 2**(%%): The upstream payload length should match the LoRaWAN length requirement (max length depends on Frequency and DR), otherwise the gateway can't decode the payload.
86 86  )))
87 87  
89 +
88 88  === 2.2.1 Decode Method ===
89 89  
90 -The decode methods: **ASCII String, Decode_LHT65** doesn't affect how the sensor data is stored, they are to define how should the sensor data to be sent.
92 +The decode methods: (% style="color:#037691" %)**ASCII String, Decode_LHT65**(%%) doesn't affect how the sensor data is stored, they are to define how should the sensor data to be sent.
91 91  
92 92  For example we have a LHT65 , works in ABP mode and gateway successful get the data, which are:
93 93  
... ... @@ -105,7 +105,7 @@
105 105  (((
106 106  Sun Sep 27 04:33:16 2020 user.notice root: [IoT.MQTT]:pub_topic[-t]: dragino-1baf44/01826108/data
107 107  Sun Sep 27 04:33:16 2020 user.notice root: [IoT.MQTT]:decoder: ASCII
108 -Sun Sep 27 04:33:16 2020 user.notice root: [IoT.MQTT]:mqtt_data[-m]: ffffffe700000048ccd17fff7fff017fff7fff00
110 +Sun Sep 27 04:33:16 2020 user.notice root: [IoT.MQTT]:mqtt_data[-m]: (% style="color:#037691" %)**ffffffe700000048ccd17fff7fff017fff7fff00**
109 109  )))
110 110  
111 111  If we choose Decode_LHT65, the MQTT process will send out with mqtt-data
... ... @@ -114,8 +114,8 @@
114 114  (((
115 115  Sun Sep 27 04:36:45 2020 user.notice root: [IoT.MQTT]:pub_topic[-t]: dragino-1baf44/01826108/data
116 116  Sun Sep 27 04:36:45 2020 user.notice root: [IoT.MQTT]:decoder: Dragino_LHT65
117 -Sun Sep 27 04:36:45 2020 user.notice root: [IoT.MQTT]:mqtt_data[-m]: {"Hum_SHT":32.7,"BatV":3.281,"TempC_DS":32.9,
118 -"EXT":"Temperature Sensor","RSSI":-24,"TempC_SHT":85.0,"SNR":8.2,"ext_sensor":0}
119 +Sun Sep 27 04:36:45 2020 user.notice root: [IoT.MQTT]:mqtt_data[-m]:** (% style="color:#037691" %){"Hum_SHT":32.7,"BatV":3.281,"TempC_DS":32.9,
120 +"EXT":"Temperature Sensor","RSSI":-24,"TempC_SHT":85.0,"SNR":8.2,"ext_sensor":0}(%%)**
119 119  )))
120 120  
121 121  Above scripts are store in /etc/lora/decoder/. User can put their scripts here and select it in the UI.
... ... @@ -149,11 +149,11 @@
149 149  
150 150  The file should use below format:
151 151  
152 -(% class="mark" %)**dev_addr,imme/time,txt/hex,payload**
154 +(% style="color:#037691" %)**dev_addr,imme/time,txt/hex,payload**
153 153  
154 154  Since fimware > Dragino-v2 lgw-5.4.1608518541 . Support more option
155 155  
156 -(% class="mark" %)**dev_addr,imme/time,txt/hex,payload,txpw,txbw,SF,frequency,rxwindow**
158 +(% style="color:#037691" %)**dev_addr,imme/time,txt/hex,payload,txpw,txbw,SF,frequency,rxwindow**
157 157  
158 158  * dev_addr: Inptu the device address
159 159  * imme/time:
... ... @@ -178,8 +178,9 @@
178 178  * Old version: echo 018193F4,imme,hex,0101 > /var/iot/push/test
179 179  * New version: echo 018193F4,imme,hex,0101,20,1,SF12,923300000,2 > /var/iot/push/test
180 180  
181 -(% class="mark" %)**Downstream Frequency**
182 182  
184 +(% style="color:#037691" %)**Downstream Frequency**
185 +
183 183  The LG308 will use the RX2 window info to send the downstream payload, use the default LoRaWAN settings, as below:
184 184  
185 185  * EU868: 869.525Mhz, DR0(SF12BW125)
... ... @@ -191,8 +191,9 @@
191 191  * IN865: 866.55Mhz, SF10 BW125
192 192  * RU864: 869.1Mhz, SF12 BW125
193 193  
194 -(% class="mark" %)**Examples:**
195 195  
198 +(% style="color:#037691" %)**Examples:**
199 +
196 196  (% class="box" %)
197 197  (((
198 198  we can use echo command to create files in LG308 for downstream.
... ... @@ -227,7 +227,7 @@
227 227  [5767501]rxDone
228 228  Rssi= -41
229 229  Receive data
230 -2:12345678    ~-~-> Hex
234 +**(% style="color:#037691" %)2:12345678**  (%%)  ~-~-> Hex
231 231  )))
232 232  
233 233  (% class="box" %)
... ... @@ -243,7 +243,7 @@
243 243  [5958595]rxDone
244 244  Rssi= -37
245 245  Receive data
246 -2:3132333435363738 ~-~-> ASCII string "12345678"
250 +**(% style="color:#037691" %)2:3132333435363738**(%%) ~-~-> ASCII string "12345678"
247 247  )))
248 248  
249 249  = 3. Example 1: Communicate with LT-22222-L =
image-20220527161119-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +128.8 KB
Content
image-20220527161149-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +103.9 KB
Content
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0