From version < 1.12 >
edited by Xiaoling
on 2022/05/12 18:09
To version < 3.5 >
edited by Xiaoling
on 2022/05/27 16:17
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -11,18 +11,19 @@
11 11  * User wants to get data forward in gateway and forward to their server base on MQTT/HTTP, etc. (Combine ABP communication method and [[MQTT forward together>>url:https://wiki.dragino.com/index.php/MQTT_Forward_Instruction]]).
12 12  
13 13  (((
14 -The basic of this feature is the decoding of **LoRaWAN ABP End Node**. Requirements:
14 +The basic of this feature is the decoding of (% style="color:red" %)**LoRaWAN ABP End Node**(%%). Requirements:
15 15  )))
16 16  
17 17  1. LoRaWAN End Node in ABP mode. Make sure your end node works in this mode. End node most are default set to OTAA mode
18 18  1. LoRaWAN Gateway model: [[LPS8>>url:http://www.dragino.com/products/lora-lorawan-gateway/item/148-lps8.html]], [[LG308>>url:http://www.dragino.com/products/lora-lorawan-gateway/item/140-lg308.html]], [[DLOS8>>url:http://www.dragino.com/products/lora-lorawan-gateway/item/160-dlos8.html]] ,[[LIG16>>url:http://www.dragino.com/products/lora-lorawan-gateway/item/171-lig16.html]]
19 -1. Firmware version for below instruction:[[Since LG02_LG08~~-~~-build-v5.4.1593400722-20200629-1120>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_Gateway/LPS8/Firmware/Release/]]
19 +1. Firmware version for below instruction:**[[(% style="color:purple" %)Since LG02_LG08~~-~~-build-v5.4.1593400722-20200629-1120>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_Gateway/LPS8/Firmware/Release/]](%%)**
20 20  
21 21  = 2. How it works =
22 22  
23 23  
24 -**Video Instruction**: [[https:~~/~~/youtu.be/ZBjXwmp7rwM>>url:https://youtu.be/ZBjXwmp7rwM]]
24 +(% style="color:#037691" %)**Video Instruction**(%%)**[[https:~~/~~/youtu.be/ZBjXwmp7rwM>>url:https://youtu.be/ZBjXwmp7rwM]]**
25 25  
26 +
26 26  Assume we have the LoRaWAN tracker LGT92 which works in ABP mode and US915 band. It has below keys:
27 27  
28 28  (% class="box infomessage" %)
... ... @@ -38,7 +38,7 @@
38 38  
39 39  We need to input above keys in LG308 and enable ABP decryption.
40 40  
41 -[[image:https://wiki.dragino.com/images/thumb/5/55/LG308_MQTT_1.png/600px-LG308_MQTT_1.png||height="329" width="600"]]
42 +[[image:image-20220527161119-1.png]]
42 42  
43 43  Input the ABP keys in LG308
44 44  
... ... @@ -51,7 +51,7 @@
51 51  We can see the log of LG308 to know this packet arrive
52 52  )))
53 53  
54 -[[image:https://wiki.dragino.com/images/thumb/1/16/ABP_DECODE_2.png/600px-ABP_DECODE_2.png||height="205" width="600"]]
55 +[[image:image-20220527161149-2.png]]
55 55  
56 56  LG308 log by "logread -f" command
57 57  
... ... @@ -61,8 +61,8 @@
61 61  (% class="box" %)
62 62  (((
63 63  root@dragino-1d25dc:~~# hexdump /var/iot/channels/2602111D
64 -0000000 (% class="mark" %)**4646 4646 4646 3946 3030 3030 3030 3546**(%%)      ~-~-> Got RSSI and SNR    
65 -0000010 (% class="mark" %)**cc0c 0b63 0266 017f ff7f ff00 **(%%) ~-~-> Payload
65 +0000000 (% style="color:#037691" %)**4646 4646 4646 3946 3030 3030 3030 3546**(%%)      ~-~-> Got RSSI and SNR    
66 +0000010 (% style="color:#037691" %)**cc0c 0b63 0266 017f ff7f ff00 **(%%) ~-~-> Payload
66 66  000001c
67 67  )))
68 68  
... ... @@ -72,8 +72,8 @@
72 72  
73 73  (% class="box" %)
74 74  (((
75 -(% class="mark" %)**Notice 1**(%%): The data file stored in LG308 for the end node is bin file. If the end node sends ASCII string to gateway, the output will as below:
76 -in LGT92, use **AT+SEND=12**:hello world to send ASCII string
76 +(% style="color:red" %)**Notice 1**(%%): The data file stored in LG308 for the end node is bin file. If the end node sends ASCII string to gateway, the output will as below:
77 +in LGT92, use **(% style="color:#037691" %)AT+SEND=12:hello world** (%%)to send ASCII string
77 77  root@dragino-1d25dc:~~# hexdump /var/iot/channels/2602111D
78 78  0000000 4646 4646 4646 3946 3030 3030 3030 3546
79 79  0000010 6865 6c6c 6f20 776f 726c 6400      ~-~-> Got ASCII code "hello world"    
... ... @@ -82,12 +82,13 @@
82 82  
83 83  (% class="box" %)
84 84  (((
85 -(% class="mark" %)**Notice 2**(%%): The upstream payload length should match the LoRaWAN length requirement (max length depends on Frequency and DR), otherwise the gateway can't decode the payload.
86 +(% style="color:#037691" %)**Notice 2**(%%): The upstream payload length should match the LoRaWAN length requirement (max length depends on Frequency and DR), otherwise the gateway can't decode the payload.
86 86  )))
87 87  
89 +
88 88  === 2.2.1 Decode Method ===
89 89  
90 -The decode methods: **ASCII String, Decode_LHT65** doesn't affect how the sensor data is stored, they are to define how should the sensor data to be sent.
92 +The decode methods: **(% style="color:#037691" %)ASCII String, Decode_LHT65**(%%) doesn't affect how the sensor data is stored, they are to define how should the sensor data to be sent.
91 91  
92 92  For example we have a LHT65 , works in ABP mode and gateway successful get the data, which are:
93 93  
image-20220527161119-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +128.8 KB
Content
image-20220527161149-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +103.9 KB
Content
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved