From version < 2.6 >
edited by Xiaoling
on 2022/07/13 17:28
To version < 2.4 >
edited by Xiaoling
on 2022/05/27 08:34
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1,21 +1,23 @@
1 1  = 1. Introduction =
2 2  
3 -
4 4  This chapter describe the checklist for not able to access to AT Command in Dragino LoRaWAN End Node base on STM32 chip.
5 5  
6 6  
7 7  = 2. Not able to send AT Command =
8 8  
9 -
10 10  * Do you use a USB to TTL Converter? If you use RS232 converter, it won't work
11 11  * Can you see the output from console.
12 12  * Do you use the correct baudrate:
13 -** (% style="color:blue" %)**Baudrate: 9600**
14 -** (% style="color:blue" %)**Data bits: 8**
15 -** (% style="color:blue" %)**Stop bits: 1**
16 -** (% style="color:blue" %)**Parity: None**
17 -** (% style="color:blue" %)**Flow control: None**
18 18  
12 +(% class="box" %)
13 +(((
14 +~** Baudrate: 9600
15 +~** Data bits: 8
16 +~** Stop bits: 1
17 +~** Parity: None
18 +~** Flow control: None
19 +)))
20 +
19 19  * Did you have the hardware RXD pin connected correctly according to the user manual?
20 20  * Did you add the **ENTER** and **NEW LINE** after press send. Some serial utility doesn't add them by default. Below is an example for adding new line:
21 21  
... ... @@ -26,7 +26,6 @@
26 26  
27 27  = 3. If you still not able to fix this issue =
28 28  
29 -
30 30  please send us below info at support@dragino.com
31 31  