2 2  
3 3  This chapter describe the checklist for not able to access to AT Command in Dragino LoRaWAN End Node base on STM32 chip.
4 4  
5 -
6 6  = 2. Not able to send AT Command =
7 7  
8 8  * Do you use a USB to TTL Converter? If you use RS232 converter, it won't work
... ... @@ -9,19 +9,17 @@
9 9  * Can you see the output from console.
10 10  * Do you use the correct baudrate:
11 11  
12 -(% class="box" %)
13 -(((
14 -~** Baudrate: 9600
15 -~** Data bits: 8
16 -~** Stop bits: 1
17 -~** Parity: None
18 -~** Flow control: None
19 -)))
11 +{{{** Baudrate: 9600
12 +** Data bits: 8
13 +** Stop bits: 1
14 +** Parity: None
15 +** Flow control: None
16 +}}}
20 20  
21 21  * Did you have the hardware RXD pin connected correctly according to the user manual?
22 22  * Did you add the **ENTER** and **NEW LINE** after press send. Some serial utility doesn't add them by default. Below is an example for adding new line:
23 23  
24 -[[image:image-20220527083416-1.png]]
21 +[[image:https://wiki.dragino.com/images/thumb/5/5c/UART_access_1.png/600px-UART_access_1.png||height="419" width="600"]]
25 25  
26 26  Add a new line in some software
27 27  