From version < 2.2 >
edited by Xiaoling
on 2022/05/27 08:34
To version < 2.6 >
edited by Xiaoling
on 2022/07/13 17:28
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1,22 +1,21 @@
1 1  = 1. Introduction =
2 2  
3 +
3 3  This chapter describe the checklist for not able to access to AT Command in Dragino LoRaWAN End Node base on STM32 chip.
4 4  
6 +
5 5  = 2. Not able to send AT Command =
6 6  
9 +
7 7  * Do you use a USB to TTL Converter? If you use RS232 converter, it won't work
8 8  * Can you see the output from console.
9 9  * Do you use the correct baudrate:
13 +** (% style="color:blue" %)**Baudrate: 9600**
14 +** (% style="color:blue" %)**Data bits: 8**
15 +** (% style="color:blue" %)**Stop bits: 1**
16 +** (% style="color:blue" %)**Parity: None**
17 +** (% style="color:blue" %)**Flow control: None**
10 10  
11 -(% class="box" %)
12 -(((
13 -~** Baudrate: 9600
14 -~** Data bits: 8
15 -~** Stop bits: 1
16 -~** Parity: None
17 -~** Flow control: None
18 -)))
19 -
20 20  * Did you have the hardware RXD pin connected correctly according to the user manual?
21 21  * Did you add the **ENTER** and **NEW LINE** after press send. Some serial utility doesn't add them by default. Below is an example for adding new line:
22 22  
... ... @@ -27,6 +27,7 @@
27 27  
28 28  = 3. If you still not able to fix this issue =
29 29  
29 +
30 30  please send us below info at support@dragino.com
31 31  
32 32  * Screen shot for your serial utility baud rate settings.
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0