<
From version < 1.4 >
edited by Xiaoling
on 2022/05/11 17:31
To version < 2.3 >
edited by Xiaoling
on 2022/05/27 08:34
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -2,6 +2,7 @@
2 2  
3 3  This chapter describe the checklist for not able to access to AT Command in Dragino LoRaWAN End Node base on STM32 chip.
4 4  
5 +
5 5  = 2. Not able to send AT Command =
6 6  
7 7  * Do you use a USB to TTL Converter? If you use RS232 converter, it won't work
... ... @@ -20,7 +20,7 @@
20 20  * Did you have the hardware RXD pin connected correctly according to the user manual?
21 21  * Did you add the **ENTER** and **NEW LINE** after press send. Some serial utility doesn't add them by default. Below is an example for adding new line:
22 22  
23 -[[image:https://wiki.dragino.com/images/thumb/5/5c/UART_access_1.png/600px-UART_access_1.png||height="419" width="600"]]
24 +[[image:image-20220527083416-1.png]]
24 24  
25 25  Add a new line in some software
26 26  
image-20220527083416-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +77.8 KB
Content
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0