Wiki source code of Change Gateway Power
Version 11.1 by Kilight Cao on 2022/06/23 14:03
Hide last authors
author | version | line-number | content |
---|---|---|---|
![]() |
8.1 | 1 | = Overview: = |
2 | |||
![]() |
9.1 | 3 | In LoRaWAN protocol, the gateway transmit packet uses the output power base on the Power Index from the LoRaWAN server downlink. for example, the LoRaWAN server sends a downlink with this info "rf_power=14", gateway got this info and it will search the index for rf_power=14 and use the related rf setting to set output power. In some cases, the LoRaWAN server might set the rf-power to a quite low value ( for example 0dB) which is not practical for use. In such a case, the User can manually change the rf_power=0's rf settings to a higher power out. Below are the methods. |
![]() |
8.1 | 4 | |
5 | |||
![]() |
7.1 | 6 | = Change Power for Semtech UDP Paket forward connection = |
![]() |
1.3 | 7 | |
![]() |
4.1 | 8 | ---- |
9 | |||
![]() |
9.1 | 10 | In LoRaWAN protocol, the gateway output power refers to the downstream packets sent by Gateway. This output power is controlled by the LoRaWAN server. |
![]() |
1.3 | 11 | |
![]() |
9.1 | 12 | Gateway maintains a power index in the file: /etc/lora/global_conf.json for example: |
![]() |
1.3 | 13 | |
![]() |
5.1 | 14 | |
![]() |
1.3 | 15 | (% class="box" %) |
16 | ((( | ||
17 | "tx_lut_3": { | ||
18 | "desc": "TX gain table, index 3", ~/~/ Index 3 refer to rf_power: 15dB. device will set the pa_gain,mix_gain,dig_gain | ||
19 | "pa_gain": 2, ~/~/ to the value mentioned here so to generate 15dB output power. | ||
20 | "mix_gain": 10, | ||
21 | "rf_power": 15, | ||
22 | "dig_gain": 1 | ||
23 | }, | ||
24 | "tx_lut_4": { | ||
25 | "desc": "TX gain table, index 4", | ||
26 | "pa_gain": 2, | ||
27 | "mix_gain": 10, | ||
28 | "rf_power": 16, | ||
29 | "dig_gain": 0 | ||
30 | ))) | ||
31 | |||
![]() |
9.1 | 32 | (% class="mark" %)Note: If when lorawan server specifies a rf_power that is not listed above. gateway will choose the closest power. profile. |
![]() |
5.1 | 33 | |
![]() |
6.1 | 34 | |
![]() |
9.1 | 35 | When the LoRaWAN server sends a downlink stream, the server will also ask the gateway to use rf_power as output. So users don't need to consider controlling on the gateway side. |
![]() |
1.3 | 36 | |
![]() |
9.1 | 37 | If users want to always use a higher power or a lower power. Users can modify the pa_gain,mix_gain, and dig_gain to specify rf_power to achieve this purpose. This is not recommended, because this might break the regulator for a specific country. |
![]() |
1.3 | 38 | |
![]() |
9.1 | 39 | Please note, that the global_conf.json file will be overwritten by the match region files in /etc/lora/cfg-30x when changing settings on the web. So the user needs to change the files in /etc/lora/cfg-cfg-30x instead of global_conf.json |
![]() |
7.1 | 40 | |
41 | |||
![]() |
9.1 | 42 | = Change Power for LoRaWAN Basic Station connection = |
![]() |
7.1 | 43 | |
![]() |
9.1 | 44 | ---- |
45 | |||
![]() |
10.1 | 46 | First, you need to find out what is the chip module of the gateway? |
![]() |
9.1 | 47 | |
![]() |
10.1 | 48 | (% class="box infomessage" %) |
49 | ((( | ||
50 | cat /var/iot/chip | ||
51 | ))) | ||
52 | |||
53 | (% class="box" %) | ||
54 | ((( | ||
55 | root@dragino-1bbe0c:~~# cat /var/iot/chip | ||
56 | sx1301 | ||
57 | root@dragino-1bbe0c:~~# | ||
58 | ))) | ||
59 | |||
![]() |
9.1 | 60 | If users want to always use a higher power or a lower power. Users can modify the pa_gain,mix_gain, and dig_gain to specify rf_power to achieve this purpose. This is not recommended, because this might break the regulator for a specific country. |
61 | |||
62 |