From version < 18.4 >
edited by Xiaoling
on 2022/07/22 15:14
To version < 18.2 >
edited by Xiaoling
on 2022/07/22 15:07
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -9,21 +9,15 @@
9 9  = 1.  Overview =
10 10  
11 11  
12 -(((
13 13  In LoRaWAN protocol, the gateway transmit packet uses the output power base on the Power Index from the LoRaWAN server downlink. for example, the LoRaWAN server sends a downlink with this info "rf_power=14", gateway got this info and it will search the index for rf_power=14 and use the related rf setting to set output power. In some cases, the LoRaWAN server might set the rf-power to a quite low value ( for example 0dB) which is not practical for use. In such a case, the User can manually change the rf_power=0's rf settings to a higher power out. Below are the methods.
14 -)))
15 15  
16 16  
17 17  = 2.  Change Power for Semtech UDP Paket forward connection =
18 18  
19 19  
20 -(((
21 21  In LoRaWAN protocol, the gateway output power refers to the downstream packets sent by Gateway. This output power is controlled by the LoRaWAN server.
22 -)))
23 23  
24 -(((
25 25  Gateway maintains a power index in the file: /etc/lora/global_conf.json for example:
26 -)))
27 27  
28 28  
29 29  (% class="box" %)
... ... @@ -30,7 +30,7 @@
30 30  (((
31 31  "tx_lut_3": {
32 32   "desc": "TX gain table, index 3",        ~/~/ Index 3 refer to rf_power: 15dB. device will set the pa_gain,mix_gain,dig_gain 
33 - "pa_gain": 2,  ~/~/ to the value mentioned here so to generate 15dB output power.
27 + "pa_gain": 2,                            ~/~/ to the value mentioned here so to generate 15dB output power.
34 34   "mix_gain": 10,
35 35   "rf_power": 15,
36 36   "dig_gain": 1
... ... @@ -44,30 +44,20 @@
44 44  )))
45 45  
46 46  
47 -(((
48 48  (% style="color:red" %)**Note: If when lorawan server specifies a rf_power that is not listed above. gateway will choose the closest power. profile.**
49 -)))
50 50  
51 51  
52 -(((
53 53  When the LoRaWAN server sends a downlink stream, the server will also ask the gateway to use rf_power as output. So users don't need to consider controlling on the gateway side.
54 -)))
55 55  
56 -(((
57 57  If users want to always use a higher power or a lower power. Users can modify the pa_gain,mix_gain, and dig_gain to specify rf_power to achieve this purpose. This is not recommended, because this might break the regulator for a specific country.
58 -)))
59 59  
60 -(((
61 61  Please note, that the global_conf.json file will be overwritten by the match region files in /etc/lora/cfg-30x when changing settings on the web. So the user needs to change the files in /etc/lora/cfg-cfg-30x instead of global_conf.json
62 -)))
63 63  
64 64  
65 65  = 3.  Change Power for LoRaWAN Basic Station connection =
66 66  
67 67  
68 -(((
69 69  First, you need to find out what is the chip module of the gateway?
70 -)))
71 71  
72 72  (% class="box infomessage" %)
73 73  (((
... ... @@ -161,26 +161,18 @@
161 161   },
162 162  )))
163 163  
164 -(((
165 165  See this link for more station configuration parameters: [[Concentrator Design (v1.5) - LoRa Basics™ StationLoRa Basics™ Station ~| DEVELOPER PORTAL (semtech.com)>>url:https://lora-developers.semtech.com/build/software/lora-basics/lora-basics-for-gateways/?url=gw_v1.5.html]]
166 -)))
167 167  
168 168  
169 -(((
170 170  If users want to always use a higher power or a lower power. Users can modify the pa_gain,mix_gain, and dig_gain to specify rf_power to achieve this purpose. This is not recommended, because this might break the regulator for a specific country.
171 -)))
172 172  
173 -(((
174 174  (% style="color:red" %)**Note: When the Settings are complete, click "Save&Apply" on the gateway's Web UI**
175 -)))
176 176  
177 177  
178 178  = 4.  Checking station Logs =
179 179  
180 180  
181 -(((
182 182  Run the command:
183 -)))
184 184  
185 185  (% class="box infomessage" %)