Changes for page Change Gateway Power
Last modified by Xiaoling on 2022/08/10 15:18
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,0 +1,42 @@ 1 += Introduction = 2 + 3 +---- 4 + 5 +((( 6 +In LoRaWAN protocol, the gateway output power refer to the downstream packets sent by Gateway. This output power is controlled by LoRaWAN server. 7 +))) 8 + 9 +((( 10 +Gateway maintain a power index in the file: /etc/lora/global_conf.json for example: 11 +))) 12 + 13 +(% class="box" %) 14 +((( 15 +((( 16 +"tx_lut_3": { 17 + "desc": "TX gain table, index 3", ~/~/ Index 3 refer to rf_power: 15dB. device will set the pa_gain,mix_gain,dig_gain 18 + "pa_gain": 2, ~/~/ to the value mentioned here so to generate 15dB output power. 19 + "mix_gain": 10, 20 + "rf_power": 15, 21 + "dig_gain": 1 22 +}, 23 +"tx_lut_4": { 24 + "desc": "TX gain table, index 4", 25 + "pa_gain": 2, 26 + "mix_gain": 10, 27 + "rf_power": 16, 28 + "dig_gain": 0 29 +))) 30 +))) 31 + 32 +((( 33 +When LoRaWAN server sends a downlink stream, server will also ask the gateway to use which rf_power as output. So user don't need to consider to control in the gateway side. 34 +))) 35 + 36 +((( 37 +If user want to always use a higher power or a lower power. User can modify the pa_gain,mix_gain,dig_gain for specify rf_power to achieve this purpose. This is not recommend, because this might break the regulator for specify country. 38 +))) 39 + 40 +((( 41 +Please note, the global_conf.json file will be overwrite by the match region files in /etc/lora/cfg-30x when change settings in the web. So user need to change the files in /etc/lora/cfg-cfg-30x instead of global_conf.json 42 +)))