... ... @@ -1,0 +1,40 @@ 1 += Introduction = 2 + 3 +((( 4 +In LoRaWAN protocol, the gateway output power refer to the downstream packets sent by Gateway. This output power is controlled by LoRaWAN server. 5 +))) 6 + 7 +((( 8 +Gateway maintain a power index in the file: /etc/lora/global_conf.json for example: 9 +))) 10 + 11 +(% class="box" %) 12 +((( 13 +((( 14 +"tx_lut_3": { 15 + "desc": "TX gain table, index 3", ~/~/ Index 3 refer to rf_power: 15dB. device will set the pa_gain,mix_gain,dig_gain 16 + "pa_gain": 2, ~/~/ to the value mentioned here so to generate 15dB output power. 17 + "mix_gain": 10, 18 + "rf_power": 15, 19 + "dig_gain": 1 20 +}, 21 +"tx_lut_4": { 22 + "desc": "TX gain table, index 4", 23 + "pa_gain": 2, 24 + "mix_gain": 10, 25 + "rf_power": 16, 26 + "dig_gain": 0 27 +))) 28 +))) 29 + 30 +((( 31 +When LoRaWAN server sends a downlink stream, server will also ask the gateway to use which rf_power as output. So user don't need to consider to control in the gateway side. 32 +))) 33 + 34 +((( 35 +If user want to always use a higher power or a lower power. User can modify the pa_gain,mix_gain,dig_gain for specify rf_power to achieve this purpose. This is not recommend, because this might break the regulator for specify country. 36 +))) 37 + 38 +((( 39 +Please note, the global_conf.json file will be overwrite by the match region files in /etc/lora/cfg-30x when change settings in the web. So user need to change the files in /etc/lora/cfg-cfg-30x instead of global_conf.json 40 +)))