Xiaoling 41.7 11 = **1. Introduction** =
Xiaoling 1.1 12
Xiaoling 1.2 13 This article provide the examples for RS485-LN to connect to different type of RS485 sensors.
Xiaoling 1.1 14
Xiaoling 38.2 15
Xiaoling 41.7 16 == **1.1 Example 1: Connect to Leak relay and VFD** ==
Xiaoling 1.1 17
Xiaoling 1.2 18 This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to Relay and VFD and communicate with Mobile. The structure is like below:
Xiaoling 1.1 19
Xiaoling 10.2 20 [[image:image-20220527091852-1.png]]
Xiaoling 1.1 21
Xiaoling 1.2 22 Connection
Xiaoling 1.1 23
Xiaoling 1.18 24
Xiaoling 1.1 25
Xiaoling 10.2 26 [[image:image-20220527091942-2.png]](% style="display:none" %)
27
Xiaoling 1.2 28 Connection
Xiaoling 1.1 29
Xiaoling 10.2 30
Xiaoling 1.2 31 Related documents:
Xiaoling 1.1 32
Xiaoling 1.2 33 * [[Solar Pump with Dragino>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Relay_VFD/]] : System Structure
34 * [[Configure Manual>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Relay_VFD/]] : Explanation on how to integrate to Node-red and to the Mobile Phone, and with link to the Github code.
35 * [[Video Demo>>url:https://www.youtube.com/watch?v=TAFZ5eaf-MY&t=6s&ab_channel=XavierFlorensaBerenguer]]
Xiaoling 1.1 36
Xiaoling 41.6 37
Xiaoling 41.10 38
Xiaoling 41.7 39 == **1.2 Example 2: Connect to Pulse Counter** ==
Xiaoling 1.1 40
Xiaoling 1.2 41 This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to Pulse Counter and communicate with Mobile. This example and example 2 compose the structure for a farm IoT solution. The structure is like below:
Xiaoling 1.1 42
Xiaoling 10.2 43 [[image:image-20220527092058-3.png]]
Xiaoling 1.1 44
Xiaoling 1.2 45 Connection
Xiaoling 1.1 46
Xiaoling 1.18 47
Xiaoling 41.11 48
Xiaoling 10.2 49 [[image:image-20220527092146-4.png]]
Xiaoling 1.2 50
51 Connection
52
Xiaoling 41.12 53
Xiaoling 1.2 54 * [[Pickdata MIO40 water pulse counter to LoRa with Dragino RS485-LN>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Pulse-Counter/]] : Configure Document
55 * [[Dragino Solution in Farm>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/&file=Dragino%20on%20Farms.pptx]]
56
Xiaoling 10.2 57 == ==
58
Xiaoling 41.7 59 == **1.3 Example3: Use RS485-LN with energy meters** ==
Xiaoling 1.2 60
Xiaoling 41.7 61 === **1.3.1 OverView** ===
Xiaoling 1.2 62
Xiaoling 1.5 63 (((
Xiaoling 1.6 64 **Note**:The specifications of each energy meter are different, please refer to your own energy meter specifications.
Xiaoling 1.5 65 )))
Xiaoling 1.2 66
Xiaoling 1.5 67 (((
Xiaoling 1.2 68 This example describes a single-phase meter.This is the connection between the RS485-LN and the energy meter.
Xiaoling 1.5 69 )))
Xiaoling 1.2 70
Xiaoling 13.2 71 [[image:image-20220527092419-5.png]]
Xiaoling 1.2 72
73 Connection1
74
Xiaoling 13.2 75
Xiaoling 41.13 76
Xiaoling 1.19 77 (((
Xiaoling 1.2 78 How to connect with Energy Meter:
Xiaoling 1.19 79 )))
Xiaoling 1.2 80
Xiaoling 1.19 81 (((
Xiaoling 1.2 82 Follow the instructions of the electric energy meter to connect the phase line and the neutral line, and then connect 485A+ and 485B- to RS485A and RA485B of RS485-LN respectively.
Xiaoling 1.19 83 )))
Xiaoling 1.2 84
Xiaoling 1.19 85 (((
Xiaoling 1.2 86 The RS485-LN can be powered by 7 ~~ 24V DC power source. Connection as below
Xiaoling 1.19 87 )))
Xiaoling 1.2 88
Xiaoling 1.19 89 (((
Xiaoling 1.2 90 Power Source VIN to RS485-LN VIN+
Xiaoling 1.19 91 )))
Xiaoling 1.2 92
Xiaoling 1.19 93 (((
Xiaoling 1.2 94 Power Source GND to RS485-LN VIN-
Xiaoling 1.19 95 )))
Xiaoling 1.2 96
Xiaoling 1.19 97 (((
Xiaoling 1.2 98 Once there is power, the RS485-LN will be on.
Xiaoling 1.19 99 )))
Xiaoling 1.2 100
Xiaoling 13.2 101 [[image:image-20220527092514-6.png]]
Xiaoling 1.2 102
103 Connection2
104
105
Xiaoling 41.14 106
Xiaoling 20.2 107 [[image:image-20220527092555-7.png]]
Xiaoling 1.12 108
Xiaoling 1.2 109 Connection3
110
111
Xiaoling 41.7 112 === **1.3.2 How to use the parameters of the energy meter and MODBUS commands** ===
Xiaoling 1.2 113
Xiaoling 1.7 114 If the user needs to read the parameters of the electric energy meter and use the modbus command,please refer to the appendix of the MODBUS communication protocol in the user manual of the energy meter.
Xiaoling 1.2 115
Xiaoling 20.2 116 [[image:image-20220527092629-8.png]]
Xiaoling 1.2 117
Xiaoling 20.2 118
Xiaoling 1.8 119 (% class="box infomessage" %)
120 (((
Xiaoling 20.2 121 **Example:** AT+COMMAND1=01 03 00 00 00 01 84 0A
Xiaoling 1.8 122 )))
Xiaoling 1.2 123
124 * The first byte : slave address code (=001~247)
125 * The second byte : read register value function code
126 * 3rd and 4th bytes: start address of register to be read
127 * 5th and 6th bytes: Number of registers to read
128 * 7th and 8th bytes: CRC16 checksum from bytes 1 to 6.
129
Xiaoling 1.12 130 (((
Xiaoling 1.2 131 How to parse the reading of the return command of the parameter:
Xiaoling 1.12 132 )))
Xiaoling 1.2 133
Xiaoling 1.8 134 (% class="box infomessage" %)
135 (((
Xiaoling 20.2 136 **Example:** RETURN1:01 03 02 08 FD 7E 05
Xiaoling 1.8 137 )))
Xiaoling 1.2 138
139 * The first byte ARD: slave address code (=001~254)
140 * The second byte: Return to read function code
141 * 3rd byte: total number of bytes
142 * 4th~5th bytes: register data
143 * The 6th and 7th bytes: CRC16 checksum
144 * 08 FD is register data. Use short integer 16 bits to convert to decimal, get 2301, then 230.1V is the voltage.
145
Xiaoling 20.2 146 (% class="wikigeneratedid" %)
147 (((
148
149 )))
150
Xiaoling 41.2 151 === **1.3.3 How to configure RS485-LN and parse output commands** ===
Xiaoling 1.2 152
153 RS485-LN provides two configuration methods: AT COMMAND and DOWNLINK.
154
Xiaoling 20.2 155
Xiaoling 41.2 156 ==== **1.3.3.1 via AT COMMAND:** ====
Xiaoling 1.2 157
Xiaoling 1.8 158 First, we can use **AT+CFGDEV** to get the return value, and we can also judge whether the input parameters are correct.
Xiaoling 1.2 159
Xiaoling 1.8 160 (((
Xiaoling 1.2 161 If the configured parameters and commands are incorrect, the return value is not obtained.
Xiaoling 1.8 162 )))
Xiaoling 1.2 163
Xiaoling 20.2 164 [[image:image-20220527092748-9.png]]
Xiaoling 1.2 165
Xiaoling 1.12 166 AT COMMAND
Xiaoling 1.2 167
Xiaoling 20.2 168
Xiaoling 1.8 169 (% class="box infomessage" %)
170 (((
Xiaoling 4.2 171 AT+DATACUTx : This command defines how to handle the return from AT+COMMANDx, max reture length is 40 bytes. AT+DATACUTx=a,b,c
Xiaoling 1.8 172 )))
Xiaoling 1.2 173
Xiaoling 41.15 174 a:  length for the return of AT+COMMAND
Xiaoling 1.2 175
Xiaoling 41.15 176 b: 1: grab valid value by byte, max 6 bytes;  2: grab valid value by bytes section, max 3 sections.
Xiaoling 1.2 177
Xiaoling 41.15 178 c:  define the position for valid value.
Xiaoling 1.2 179
Xiaoling 20.2 180 [[image:image-20220527092936-10.png]]
Xiaoling 1.2 181
182 AT COMMAND
183
Xiaoling 20.2 184
Xiaoling 41.15 185
Xiaoling 1.2 186 PAYLOAD is available after the valid value is intercepted.
187
Xiaoling 1.8 188
Xiaoling 20.2 189 [[image:image-20220527093059-11.png]]
Xiaoling 1.2 190
191 AT COMMAND
192
Xiaoling 20.2 193
Xiaoling 41.16 194
Xiaoling 1.2 195 You can get configured PAYLOAD on TTN.
196
Xiaoling 20.2 197 [[image:image-20220527093133-12.png]]
Xiaoling 1.8 198
Xiaoling 1.12 199 (((
Xiaoling 1.2 200 AT COMMAND
Xiaoling 1.12 201 )))
Xiaoling 1.2 202
Xiaoling 1.12 203 (((
Xiaoling 1.13 204
205 )))
206
207 (((
Xiaoling 39.4 208 (% style="color:#4f81bd" %)**Example**:
Xiaoling 39.3 209
210 CMD1:Read current data with MODBUS command. address:0x03 AT+COMMAND1= 01 03 00 03 00 01,1
Xiaoling 1.12 211 )))
Xiaoling 1.2 212
Xiaoling 1.12 213 (((
Xiaoling 1.2 214 RETURN1:01 03 02 00 02 39 85 00 00(return data)
Xiaoling 1.12 215 )))
Xiaoling 1.2 216
Xiaoling 1.12 217 (((
Xiaoling 1.2 218 AT+DATACUT1:9,1,4+5+6+7 Take the return value 00 02 39 85 as the valid value of reading current data and used to splice payload.
Xiaoling 39.3 219
220
Xiaoling 1.12 221 )))
Xiaoling 1.2 222
Xiaoling 1.12 223 (((
Xiaoling 1.2 224 CMD2:Read voltage data with MODBUS command. address:0x00 AT+COMMAND2= 01 03 00 00 00 01,1
Xiaoling 1.12 225 )))
Xiaoling 1.2 226
Xiaoling 1.12 227 (((
Xiaoling 1.2 228 RETURN2:01 03 02 08 DC BE 1D(return data)
Xiaoling 1.12 229 )))
Xiaoling 1.2 230
Xiaoling 1.12 231 (((
Xiaoling 1.2 232 AT+DATACUT2:7,1,4+5 Take the return value 08 DC as the valid value of reading voltage data and used to splice payload.
Xiaoling 39.3 233
234
Xiaoling 1.12 235 )))
Xiaoling 1.2 236
Xiaoling 1.12 237 (((
Xiaoling 1.2 238 CMD3:Read total active energy data with MODBUS command. address:0x0031 AT+COMMAND3= 01 03 00 31 00 02,1
Xiaoling 1.12 239 )))
Xiaoling 1.2 240
Xiaoling 1.12 241 (((
Xiaoling 1.2 242 RETURN3:01 03 04 00 00 00 44 FA 00(return data)
Xiaoling 1.12 243 )))
Xiaoling 1.2 244
Xiaoling 1.12 245 (((
Xiaoling 1.2 246 AT+DATACUT3:9,1,4+5+6+7 Take the return value 00 00 00 44 as the valid value of reading total active energy data and used to splice payload.
Xiaoling 1.12 247 )))
Xiaoling 1.2 248
Xiaoling 1.12 249 (((
Xiaoling 1.2 250 Payload:01 00 02 39 85 08 DC 00 00 00 44
Xiaoling 1.12 251 )))
Xiaoling 1.2 252
Xiaoling 20.2 253 [[image:image-20220527093204-13.png]]
Xiaoling 1.2 254
255 AT COMMAND
256
Xiaoling 20.2 257
Xiaoling 21.2 258 (% style="color:#4f81bd" %)**01 is device address,00 02 is the current, 08 DC is the voltage,00 00 00 44 is the total active energy.**
Xiaoling 1.2 259
Xiaoling 41.17 260
261
Xiaoling 20.2 262 [[image:image-20220527093251-14.png]]
Xiaoling 1.8 263
Xiaoling 1.2 264 AT COMMAND
265
266
Xiaoling 41.2 267 ==== **1.3.3.2 via LoRaWAN DOWNLINK** ====
Xiaoling 1.8 268
Xiaoling 21.2 269 [[image:image-20220527093358-15.png]]
Xiaoling 1.2 270
Xiaoling 1.9 271 (((
Xiaoling 1.2 272 DOWNLINK
Xiaoling 1.9 273 )))
Xiaoling 1.2 274
Xiaoling 1.9 275 (((
276
277 )))
278
279 (((
Xiaoling 39.4 280 (% style="color:#4f81bd" %)**Type Code 0xAF**
Xiaoling 1.9 281 )))
Xiaoling 1.2 282
Xiaoling 1.9 283 (((
Xiaoling 4.3 284 (% class="box infomessage" %)
285 (((
Xiaoling 1.2 286 0xAF downlink command can be used to set AT+COMMANDx or AT+DATACUTx.
Xiaoling 1.9 287 )))
Xiaoling 4.3 288 )))
Xiaoling 1.2 289
Xiaoling 1.9 290 (((
Xiaoling 1.2 291 Note: if user use AT+COMMANDx to add a new command, he also need to send AT+DATACUTx downlink.
Xiaoling 1.9 292 )))
Xiaoling 1.2 293
Xiaoling 1.9 294 (((
Xiaoling 1.2 295 Format: AF MM NN LL XX XX XX XX YY
Xiaoling 1.9 296 )))
Xiaoling 1.2 297
Xiaoling 1.9 298 (((
Xiaoling 1.2 299 Where:
Xiaoling 1.9 300 )))
Xiaoling 1.2 301
Xiaoling 1.9 302 (((
Xiaoling 1.2 303 MM: the ATCOMMAND or AT+DATACUT to be set. Value from 01 ~~ 0F,
Xiaoling 1.9 304 )))
Xiaoling 1.2 305
Xiaoling 1.9 306 (((
Xiaoling 1.2 307 NN: 0: no CRC; 1: add CRC-16/MODBUS ; 2: set the AT+DATACUT value.
Xiaoling 1.9 308 )))
Xiaoling 1.2 309
Xiaoling 1.9 310 (((
Xiaoling 1.2 311 LL: The length of AT+COMMAND or AT+DATACUT command
Xiaoling 1.9 312 )))
Xiaoling 1.2 313
Xiaoling 1.9 314 (((
Xiaoling 1.2 315 XX XX XX XX: AT+COMMAND or AT+DATACUT command
Xiaoling 1.9 316 )))
Xiaoling 1.2 317
Xiaoling 1.9 318 (((
Xiaoling 1.2 319 YY: If YY=0, RS485-LN will execute the downlink command without uplink; if YY=1, RS485-LN
Xiaoling 1.9 320 )))
Xiaoling 1.2 321
Xiaoling 1.9 322 (((
Xiaoling 1.2 323 will execute an uplink after got this command.
Xiaoling 1.9 324 )))
Xiaoling 1.2 325
Xiaoling 1.9 326 (((
Xiaoling 41.18 327
328
Xiaoling 39.4 329 (% style="color:#4f81bd" %)**Example:**
Xiaoling 1.9 330 )))
Xiaoling 1.2 331
Xiaoling 1.9 332 (((
Xiaoling 39.4 333 **AF 03 01 06 0A 05 00 04 00 01 00**: Same as AT+COMMAND3=0A 05 00 04 00 01,1
Xiaoling 1.9 334 )))
Xiaoling 1.2 335
Xiaoling 22.2 336 [[image:image-20220527093430-16.png]]
Xiaoling 1.2 337
338 DOWNLINK
339
Xiaoling 1.8 340
Xiaoling 41.19 341
Xiaoling 24.2 342 [[image:image-20220527093508-17.png]]
Xiaoling 1.2 343
344 DOWNLINK
345
Xiaoling 1.8 346
Xiaoling 41.20 347
Xiaoling 24.2 348 [[image:image-20220527093530-18.png]]
Xiaoling 1.2 349
350 DOWNLINK
351
Xiaoling 1.8 352
Xiaoling 41.21 353
Xiaoling 26.2 354 [[image:image-20220527093607-19.png]]
Xiaoling 1.2 355
356 DOWNLINK
357
Xiaoling 1.15 358
Xiaoling 26.2 359 [[image:image-20220527093628-20.png]]
Xiaoling 1.2 360
361 DOWNLINK
362
363
Xiaoling 41.2 364 === **1.3.4 How to configure and output commands for RS485 to USB** ===
Xiaoling 1.2 365
Xiaoling 1.13 366 (((
Xiaoling 1.2 367 This step is not necessary, it is just to show how to use a normal RS485 to USB adapter to connect to the meter to check the input and output. This can be used to test the connection and RS485 command of the meter without RS485-LN.
Xiaoling 1.13 368 )))
Xiaoling 1.2 369
Xiaoling 1.13 370 (((
Xiaoling 1.2 371 First, connect the A+ and A- of the USB to the 485 A and 485 B of the energy meter.
Xiaoling 1.13 372 )))
Xiaoling 1.2 373
Xiaoling 1.13 374 (((
Xiaoling 1.2 375 Open the serial port debugging, set the send and receive to HEX.
Xiaoling 1.13 376 )))
Xiaoling 1.2 377
Xiaoling 1.13 378 (((
Xiaoling 1.2 379 Baud rate: 9600
Xiaoling 1.13 380 )))
Xiaoling 1.2 381
Xiaoling 1.13 382 (((
Xiaoling 1.2 383 check digit: Even
Xiaoling 1.13 384 )))
Xiaoling 1.2 385
Xiaoling 27.2 386 [[image:image-20220527093708-21.png]]
Xiaoling 1.2 387
388 USB
389
Xiaoling 1.13 390
Xiaoling 29.2 391 [[image:image-20220527093747-22.png]]
Xiaoling 1.2 392
393 USB
394
Xiaoling 1.13 395
396 (((
Xiaoling 1.2 397 The configuration command is consistent with the AT command, input the hexadecimal command directly into the serial port, and the serial port will output the command.
Xiaoling 1.13 398 )))
Xiaoling 1.2 399
Xiaoling 1.13 400 (((
Xiaoling 39.4 401 (% style="color:#4f81bd" %)**Example:**  (%%)input:01 03 00 31 00 02 95 c4
Xiaoling 1.13 402 )))
Xiaoling 1.2 403
Xiaoling 1.13 404 (((
Xiaoling 4.6 405 output:01 03 04 00 00 00 42 7A 02
Xiaoling 1.13 406 )))
Xiaoling 1.2 407
Xiaoling 29.2 408 [[image:image-20220527093821-23.png]]
Xiaoling 1.2 409
410 USB
411
Xiaoling 29.2 412
Xiaoling 41.2 413 === **1.3.5 How to configure multiple devices and modify device addresses** ===
Xiaoling 1.2 414
415 If users need to read the parameters of multiple energy meters, they need to modify the device address, because the default device address of each energy meter is 01.
416
Xiaoling 1.14 417 (((
Xiaoling 1.15 418 (((
Xiaoling 1.2 419 Set the device address according to the parameters in the appendix of the MODBUS communication protocol.
Xiaoling 1.14 420 )))
Xiaoling 1.15 421 )))
Xiaoling 1.2 422
Xiaoling 30.2 423 [[image:image-20220527093849-24.png]]
Xiaoling 1.2 424
Xiaoling 30.2 425
Xiaoling 1.16 426 **Example**:These two meters are examples of setting parameters and device addresses.
Xiaoling 1.2 427
Xiaoling 31.2 428 [[image:image-20220527093950-25.png]]
Xiaoling 1.2 429
Xiaoling 32.2 430 [[image:image-20220527094028-26.png]]
Xiaoling 1.2 431
Xiaoling 1.14 432 (((
Xiaoling 1.16 433 (((
Xiaoling 1.2 434 First of all, since the default device address of the energy meter is 01, the configuration of two energy meters will conflict, so we first connect an energy meter and configure the device address.
Xiaoling 1.14 435 )))
Xiaoling 1.16 436 )))
Xiaoling 1.2 437
Xiaoling 1.14 438 (((
Xiaoling 1.16 439 (((
Xiaoling 1.2 440 We can use AT+CFGDEV to set the device address.
Xiaoling 1.14 441 )))
Xiaoling 1.16 442 )))
Xiaoling 1.2 443
Xiaoling 1.14 444 (((
Xiaoling 1.16 445 (((
Xiaoling 1.2 446 We modify the device address 01 of the first energy meter to 02.
Xiaoling 1.14 447 )))
Xiaoling 1.16 448 )))
Xiaoling 1.2 449
Xiaoling 35.2 450 [[image:image-20220527094100-27.png]]
Xiaoling 1.2 451
Xiaoling 35.2 452 (% class="box infomessage" %)
453 (((
454 **AT+CFGDEV:01 10 00 61 00 01 02 00 02,1**
455 )))
Xiaoling 1.2 456
457 * 01:device adaress
458
459 * 10:function code
460
461 * 00 61:Register address
462
463 * 00 01:Number of Registers
464
465 * 02:Number of bytes
466
467 * 00 02:Modified device address
468
469 * 1:Check code
470
471 The device address setting of the energy meter is complete.
472
473 Another energy meter is a single active energy meter with a floating-point format.
474
475 Its default device address is 01, and the following are the parameters for configuring two energy meters.
476
Xiaoling 35.2 477 [[image:image-20220527094150-28.png]]
Xiaoling 1.2 478
479
Xiaoling 35.2 480 [[image:image-20220527094224-29.png]]
481
Xiaoling 39.5 482 **PAYLOAD:01 08 DF 43 62**
Xiaoling 1.2 483
484 * 08 DF is the valid value of the meter with device address 02.
485 * 43 62 is the valid value of the meter with device address 01.
486
Xiaoling 39.5 487
Xiaoling 1.2 488 == 1.4 Example 4: Circuit Breaker Remote Open Close ==
489
490 This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to SCHNEIDER SMART and Monitor and control your cabinet remotely with no wires and with Dragino RS485-LN LoRaWAN technology. The structure is like below:
491
Xiaoling 36.2 492 [[image:image-20220527094330-30.png]]
Xiaoling 1.2 493
494 Connection
495
496 * [[Circuit Breaker Remote Open Close>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Circuit_Breaker_Remote_Open_Close/]] : Configure Documen
497
Xiaoling 41.9 498
Xiaoling 1.2 499 == 1.5 Example 5: SEM Three Energy Meter with RS485-BL or RS485-LN ==
500
501 This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-BL to connect to SEM Three Energy Meter and send the data to mobile phone for remote minitor. The structure is like below:
502
503 * [[Connect to SEM Three>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/RS485-BL/Application_Note/&file=Dragino%20RS485BL%20and%20pickdata%20SEM%20Three%20v1.pdf]] : Configure Document For RS485-BL
504
505 * [[Connect to SEM Three>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/SEM_Three_Energy_Meter/&file=SEM%20three%20and%20Dragino%20RS485-LN%20v1.pdf]] : Configure Document for RS485-LN
506
507 == 1.6 Example 6:CEM C31 485-T1-MID Energy Meter with RS485-LN ==
508
509 This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to CEM C31 485-T1-MID and send the data for remote minitor. The structure is like below:
510
511 * [[CEM C31 485-T1-MID>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/ELECTRICAL%20CABINET/&file=ELECTRICAL%20CABINET%20READINGS.pdf]] : Configure Document For RS485-LN
512
513 == 1.7 Example 7:Schneider Electric PLC M221 with RS485-BL ==
514
Xiaoling 38.1 515 [[image:image-20220527094556-31.png]]
Xiaoling 1.2 516
517 Network Structure
518
519 * [[Reference Instruction>>url:https://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Schneider%20Electric%20PLC/]]