Last modified by Karry Zhuang on 2024/07/11 11:58
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 6 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,8 +6,3 @@ 1 -(% class="wikigeneratedid" %) 2 - **Contents:** 3 - 4 -{{toc/}} 5 - 6 6 = 1. Introduction = 7 7 8 8 This article provide the examples for RS485-LN to connect to different type of RS485 sensors. ... ... @@ -15,7 +15,6 @@ 15 15 16 16 Connection 17 17 18 - 19 19 [[image:https://wiki.dragino.com/images/thumb/f/f2/RS485_02.png/600px-RS485_02.png||height="743" width="528"]](% style="display:none" %) 20 20 21 21 Connection ... ... @@ -34,7 +34,6 @@ 34 34 35 35 Connection 36 36 37 - 38 38 [[image:https://wiki.dragino.com/images/thumb/5/5f/RS485_02_2.png/600px-RS485_02_2.png||height="337" width="600"]] 39 39 40 40 Connection ... ... @@ -58,29 +58,17 @@ 58 58 59 59 Connection1 60 60 61 -((( 62 62 How to connect with Energy Meter: 63 -))) 64 64 65 -((( 66 66 Follow the instructions of the electric energy meter to connect the phase line and the neutral line, and then connect 485A+ and 485B- to RS485A and RA485B of RS485-LN respectively. 67 -))) 68 68 69 -((( 70 70 The RS485-LN can be powered by 7 ~~ 24V DC power source. Connection as below 71 -))) 72 72 73 -((( 74 74 Power Source VIN to RS485-LN VIN+ 75 -))) 76 76 77 -((( 78 78 Power Source GND to RS485-LN VIN- 79 -))) 80 80 81 -((( 82 82 Once there is power, the RS485-LN will be on. 83 -))) 84 84 85 85 [[image:https://wiki.dragino.com/images/thumb/1/15/Meter2.jpg/600px-Meter2.jpg||height="433" width="577"]] 86 86 ... ... @@ -143,7 +143,7 @@ 143 143 144 144 (% class="box infomessage" %) 145 145 ((( 146 - 127 +AT+DATACUTx : This command defines how to handle the return from AT+COMMANDx, max reture length is 40 bytes. AT+DATACUTx=a,b,c 147 147 ))) 148 148 149 149 a: length for the return of AT+COMMAND ... ... @@ -230,7 +230,7 @@ 230 230 231 231 ==== 1.3.3.2 via LoRaWAN DOWNLINK ==== 232 232 233 -[[image:image -20220512104358-3.png]]214 +[[image:https://wiki.dragino.com/images/thumb/f/fc/DOWNLINK_METER1.png/600px-DOWNLINK_METER1.png||height="423" width="600"]] 234 234 235 235 ((( 236 236 DOWNLINK ... ... @@ -241,15 +241,12 @@ 241 241 ))) 242 242 243 243 ((( 244 - **Type Code 0xAF**225 +Type Code 0xAF 245 245 ))) 246 246 247 247 ((( 248 -(% class="box infomessage" %) 249 -((( 250 250 0xAF downlink command can be used to set AT+COMMANDx or AT+DATACUTx. 251 251 ))) 252 -))) 253 253 254 254 ((( 255 255 Note: if user use AT+COMMANDx to add a new command, he also need to send AT+DATACUTx downlink. ... ... @@ -361,7 +361,7 @@ 361 361 ))) 362 362 363 363 ((( 364 - output :01 03 04 00 00 00 42 7A 02342 + output:01 03 04 00 00 00 42 7A 02 365 365 ))) 366 366 367 367 [[image:https://wiki.dragino.com/images/thumb/b/b3/Usb_meter3.jpg/600px-Usb_meter3.jpg||height="466" width="600"]] ... ... @@ -380,29 +380,23 @@ 380 380 381 381 [[image:https://wiki.dragino.com/images/thumb/1/1f/Double_meter3.png/600px-Double_meter3.png||alt="Double meter3.png" height="83" width="600"]] 382 382 383 - **Example**:These two meters are examples of setting parameters and device addresses.361 +Example:These two meters are examples of setting parameters and device addresses. 384 384 385 -[[image:https://wiki.dragino.com/images/thumb/e/ee/Double_meter1.jpg/600px-Double_meter1.jpg||alt="Double meter1.jpg" height=" 737" width="553"]]363 +[[image:https://wiki.dragino.com/images/thumb/e/ee/Double_meter1.jpg/600px-Double_meter1.jpg||alt="Double meter1.jpg" height="800" width="600"]] 386 386 387 387 [[image:https://wiki.dragino.com/images/thumb/7/72/Double_meter2.jpg/600px-Double_meter2.jpg||alt="Double meter2.jpg" height="733" width="550"]] 388 388 389 389 ((( 390 -((( 391 391 First of all, since the default device address of the energy meter is 01, the configuration of two energy meters will conflict, so we first connect an energy meter and configure the device address. 392 392 ))) 393 -))) 394 394 395 395 ((( 396 -((( 397 397 We can use AT+CFGDEV to set the device address. 398 398 ))) 399 -))) 400 400 401 401 ((( 402 -((( 403 403 We modify the device address 01 of the first energy meter to 02. 404 404 ))) 405 -))) 406 406 407 407 [[image:https://wiki.dragino.com/images/6/6b/Double_meter4.png||alt="Double meter4.png" height="141" width="456"]] 408 408
- image-20220512104203-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -77.5 KB - Content
- image-20220512104238-2.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -81.2 KB - Content
- image-20220512104358-3.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -80.8 KB - Content
- image-20220512115601-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -20.4 KB - Content
- image-20220527091852-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -542.6 KB - Content
- image-20220527091942-2.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -608.5 KB - Content