562 562  It shows how to use RS485-LN to connect to an ultrasonic flow meter and read the data from the ultrasonic flow meter.
563 563  
564 564  
565 -Need to prepare RS485-LN, recharger, Electric wire
566 566  
567 -[[image:1720669739434-926.png]] [[image:1720669744315-613.png]]
568 -
569 -
570 -=== 1.9.1 Setting Ultrasonic Flowmeter ===
571 -
572 -
573 -Adjust the M option corresponding to the ultrasonic flowmeter as follows
574 -
575 -M52 sets RS485 Port.
576 -
577 -[[image:1720669933691-331.png]]
578 -
579 -
580 -M62 sets 9600, none, 1
581 -
582 -[[image:1720669981767-254.png]]
583 -
584 -
585 -M63 sets automatic
586 -
587 -[[image:1720670003601-544.png]]
588 -
589 -
590 -=== 1.9.2 Setting Dragino RS485-LN ===
591 -
592 -
593 -The RS485-LN wiring port is as shown below. Connect the power supply and RS485 A/B line according to the diagram.
594 -
595 -[[image:1720670016539-422.png]][[image:1720670019136-658.png]]
596 -
597 -
598 -=== 1.9.3 Connect the RS485-LN to Ultrasonic Flowmeter ===
599 -
600 -
601 -According to the instructions of the ultrasonic flow meter, 26 and 27 are the + and - of RS485, corresponding to the A and B ports of RS485.
602 -
603 -[[image:1720670035661-234.png]][[image:1720670041974-372.png||height="417" width="436"]]
604 -
605 -
606 -=== 1.9.4 Full wiring example ===
607 -
608 -
609 -The yellow wire connects port 26 and port A of RS485-LN.
610 -
611 -The green wire connects port 27 and port B of RS485-LN.
612 -
613 -[[image:1720670079781-764.png]]
614 -
615 -
616 -=== 1.9.5 How to read ultrasonic flow meter data via RS485 ===
617 -
618 -
619 -[[image:1720670090204-634.png]]
620 -
621 -
622 -For example, I want to read Positive
623 -
624 -Through M02, we can see that the POS data is 54.9862
625 -
626 -[[image:1720670103571-173.png]][[image:1720670108127-723.png||height="597" width="645"]]
627 -
628 -Registers are 9-12, so the read command is AT+CFGDEV=01 03 00 08 00 04,1(,1 is used for automatic complement)
629 -
630 -[[image:1720670123955-149.png]]
631 -
632 -AT+CFGDEV=01 03 00 08 00 04 c5 cb ,1
633 -
634 -RETURN DATA:
635 -
636 -01 03 08 00 36 00 00 78 79 3f 7c 1a bc
637 -
638 -
639 -OK
640 -
641 -
642 -00 36 00 00 is the integer of the read value
643 -
644 -78 79 3f 7c is a decimal, but it needs to be converted and parsed into floating point. The parsing order is CDAB, which is 3f 7c 78 79
645 -
646 -Conversion and parsing website:http:~/~/www.speedfly.cn/tools/hexconvert/
647 -
648 -[[image:1720670134750-980.png]]
649 -
650 -
566 +* **Specific steps**:  RS485-LN with ultrasonic flow meter
567 +*
1720670123955-149.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.karry
Size
... ... @@ -1,1 +1,0 @@
1 -22.1 KB
Content
1720670134750-980.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.karry
Size
... ... @@ -1,1 +1,0 @@
1 -116.5 KB
Content
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0