... ... @@ -13,13 +13,11 @@ 13 13 This article provide the examples for RS485-LN to connect to different type of RS485 sensors. 14 14 15 15 16 - 17 17 == **1.1 Example 1: Connect to Leak relay and VFD** == 18 18 19 19 20 20 This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to Relay and VFD and communicate with Mobile. The structure is like below: 21 21 22 - 23 23 [[image:image-20220527091852-1.png]] 24 24 25 25 Connection ... ... @@ -39,6 +39,7 @@ 39 39 40 40 41 41 40 + 42 42 == **1.2 Example 2: Connect to Pulse Counter** == 43 43 44 44 ... ... @@ -63,6 +63,7 @@ 63 63 64 64 65 65 65 + 66 66 == **1.3 Example3: Use RS485-LN with energy meters** == 67 67 68 68 ... ... @@ -70,13 +70,11 @@ 70 70 71 71 72 72 ((( 73 -(% style="color:red" %)**Note**: **The specifications of each energy meter are different, please refer to your own energy meter specifications.**73 +(% style="color:red" %)**Note**:The specifications of each energy meter are different, please refer to your own energy meter specifications. 74 74 ))) 75 75 76 76 ((( 77 77 This example describes a single-phase meter.This is the connection between the RS485-LN and the energy meter. 78 - 79 - 80 80 ))) 81 81 82 82 [[image:image-20220527092419-5.png]] ... ... @@ -179,8 +179,6 @@ 179 179 180 180 ((( 181 181 If the configured parameters and commands are incorrect, the return value is not obtained. 182 - 183 - 184 184 ))) 185 185 186 186 [[image:image-20220601143201-9.png]] ... ... @@ -231,7 +231,6 @@ 231 231 ((( 232 232 (% style="color:blue" %)**Example**: 233 233 234 - 235 235 (% style="color:red" %)**CMD1:**(%%) Read current data with MODBUS command. address: 0x03 AT+COMMAND1= 01 03 00 03 00 01,1 236 236 ))) 237 237 ... ... @@ -273,8 +273,6 @@ 273 273 274 274 ((( 275 275 Payload: 01 00 02 39 85 08 DC 00 00 00 44 276 - 277 - 278 278 ))) 279 279 280 280 [[image:image-20220601142936-6.png]] ... ... @@ -283,7 +283,7 @@ 283 283 284 284 285 285 286 -(% style="color:b lue" %)**01 is device address,00 02 is the current, 08 DC is the voltage,00 00 00 44 is the total active energy.**279 +(% style="color:#4f81bd" %)**01 is device address,00 02 is the current, 08 DC is the voltage,00 00 00 44 is the total active energy.** 287 287 288 288 289 289 [[image:image-20220601143642-2.png]] ... ... @@ -306,7 +306,7 @@ 306 306 ))) 307 307 308 308 ((( 309 -(% style="color:b lue" %)**Type Code 0xAF**302 +(% style="color:#4f81bd" %)**Type Code 0xAF** 310 310 ))) 311 311 312 312 ((( ... ... @@ -469,7 +469,6 @@ 469 469 470 470 (% style="color:blue" %)**Example**(%%): These two meters are examples of setting parameters and device addresses. 471 471 472 - 473 473 [[image:image-20220527093950-25.png]] 474 474 475 475