... ... @@ -20,7 +20,7 @@ 20 20 This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to Relay and VFD and communicate with Mobile. The structure is like below: 21 21 22 22 23 -[[image:image-20220527091852-1.png]] 23 +[[image:image-20220527091852-1.png||height="547" width="994"]] 24 24 25 25 Connection 26 26 ... ... @@ -39,7 +39,6 @@ 39 39 40 40 41 41 42 - 43 43 == **1.2 Example 2: Connect to Pulse Counter** == 44 44 45 45 ... ... @@ -46,13 +46,13 @@ 46 46 This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to Pulse Counter and communicate with Mobile. This example and example 2 compose the structure for a farm IoT solution. The structure is like below: 47 47 48 48 49 -[[image:image-20220527092058-3.png]] 48 +[[image:image-20220527092058-3.png||height="552" width="905"]] 50 50 51 51 Connection 52 52 53 53 54 54 55 -[[image:image-20220527092146-4.png]] 54 +[[image:image-20220527092146-4.png||height="507" width="906"]] 56 56 57 57 Connection 58 58 ... ... @@ -62,12 +62,9 @@ 62 62 * Configure Document: [[Pickdata MIO40 water pulse counter to LoRa with Dragino RS485-LN>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Pulse-Counter/||_mstmutation="1"]] 63 63 * [[Dragino Solution in Farm>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/&file=Dragino%20on%20Farms.pptx]] 64 64 64 +== **1.3 Example 3: Use RS485-LN with energy meters** == 65 65 66 66 67 - 68 -== **1.3 Example3: Use RS485-LN with energy meters** == 69 - 70 - 71 71 === **1.3.1 OverView** === 72 72 73 73 ... ... @@ -471,6 +471,7 @@ 471 471 472 472 (% style="color:blue" %)**Example**(%%): These two meters are examples of setting parameters and device addresses. 473 473 470 + 474 474 [[image:image-20220527093950-25.png]] 475 475 476 476 ... ... @@ -534,6 +534,10 @@ 534 534 * 08 DF is the valid value of the meter with device address 02. 535 535 * 43 62 is the valid value of the meter with device address 01. 536 536 534 +(% style="display:none" %) (%%) 535 + 536 +(% style="display:none" %) (%%) 537 + 537 537 == 1.4 Example 4: Circuit Breaker Remote Open Close == 538 538 539 539 ... ... @@ -548,6 +548,7 @@ 548 548 549 549 * Configure Documen: [[Circuit Breaker Remote Open Close>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Circuit_Breaker_Remote_Open_Close/||_mstmutation="1"]] 550 550 552 + 551 551 == 1.5 Example 5: SEM Three Energy Meter with RS485-BL or RS485-LN == 552 552 553 553 ... ... @@ -556,6 +556,8 @@ 556 556 * Configure Document For RS485-BL: [[Connect to SEM Three>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/RS485-BL/Application_Note/&file=Dragino%20RS485BL%20and%20pickdata%20SEM%20Three%20v1.pdf||_mstmutation="1" style="background-color: rgb(255, 255, 255);"]] 557 557 * Configure Document for RS485-LN: [[Connect to SEM Three>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/SEM_Three_Energy_Meter/&file=SEM%20three%20and%20Dragino%20RS485-LN%20v1.pdf||_mstmutation="1"]] 558 558 561 + 562 + 559 559 == 1.6 Example 6: CEM C31 485-T1-MID Energy Meter with RS485-LN == 560 560 561 561 ... ... @@ -563,6 +563,8 @@ 563 563 564 564 * Configure Document For RS485-LN: [[CEM C31 485-T1-MID>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/ELECTRICAL%20CABINET/&file=ELECTRICAL%20CABINET%20READINGS.pdf||_mstmutation="1" style="background-color: rgb(255, 255, 255);"]] 565 565 570 + 571 + 566 566 == 1.7 Example 7: Schneider Electric PLC M221 with RS485-BL == 567 567 568 568