Last modified by Karry Zhuang on 2024/07/11 11:58
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -13,13 +13,11 @@ 13 13 This article provide the examples for RS485-LN to connect to different type of RS485 sensors. 14 14 15 15 16 - 17 17 == **1.1 Example 1: Connect to Leak relay and VFD** == 18 18 19 19 20 20 This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to Relay and VFD and communicate with Mobile. The structure is like below: 21 21 22 - 23 23 [[image:image-20220527091852-1.png]] 24 24 25 25 Connection ... ... @@ -75,8 +75,6 @@ 75 75 76 76 ((( 77 77 This example describes a single-phase meter.This is the connection between the RS485-LN and the energy meter. 78 - 79 - 80 80 ))) 81 81 82 82 [[image:image-20220527092419-5.png]] ... ... @@ -179,8 +179,6 @@ 179 179 180 180 ((( 181 181 If the configured parameters and commands are incorrect, the return value is not obtained. 182 - 183 - 184 184 ))) 185 185 186 186 [[image:image-20220601143201-9.png]] ... ... @@ -231,7 +231,6 @@ 231 231 ((( 232 232 (% style="color:blue" %)**Example**: 233 233 234 - 235 235 (% style="color:red" %)**CMD1:**(%%) Read current data with MODBUS command. address: 0x03 AT+COMMAND1= 01 03 00 03 00 01,1 236 236 ))) 237 237 ... ... @@ -273,8 +273,6 @@ 273 273 274 274 ((( 275 275 Payload: 01 00 02 39 85 08 DC 00 00 00 44 276 - 277 - 278 278 ))) 279 279 280 280 [[image:image-20220601142936-6.png]] ... ... @@ -283,7 +283,7 @@ 283 283 284 284 285 285 286 -(% style="color:b lue" %)**01 is device address,00 02 is the current, 08 DC is the voltage,00 00 00 44 is the total active energy.**277 +(% style="color:#4f81bd" %)**01 is device address,00 02 is the current, 08 DC is the voltage,00 00 00 44 is the total active energy.** 287 287 288 288 289 289 [[image:image-20220601143642-2.png]] ... ... @@ -546,6 +546,8 @@ 546 546 547 547 * Configure Documen: [[Circuit Breaker Remote Open Close>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Circuit_Breaker_Remote_Open_Close/||_mstmutation="1"]] 548 548 540 + 541 + 549 549 == 1.5 Example 5: SEM Three Energy Meter with RS485-BL or RS485-LN == 550 550 551 551 ... ... @@ -554,6 +554,8 @@ 554 554 * Configure Document For RS485-BL: [[Connect to SEM Three>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/RS485-BL/Application_Note/&file=Dragino%20RS485BL%20and%20pickdata%20SEM%20Three%20v1.pdf||_mstmutation="1" style="background-color: rgb(255, 255, 255);"]] 555 555 * Configure Document for RS485-LN: [[Connect to SEM Three>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/SEM_Three_Energy_Meter/&file=SEM%20three%20and%20Dragino%20RS485-LN%20v1.pdf||_mstmutation="1"]] 556 556 550 + 551 + 557 557 == 1.6 Example 6: CEM C31 485-T1-MID Energy Meter with RS485-LN == 558 558 559 559 ... ... @@ -561,6 +561,8 @@ 561 561 562 562 * Configure Document For RS485-LN: [[CEM C31 485-T1-MID>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/ELECTRICAL%20CABINET/&file=ELECTRICAL%20CABINET%20READINGS.pdf||_mstmutation="1" style="background-color: rgb(255, 255, 255);"]] 563 563 559 + 560 + 564 564 == 1.7 Example 7: Schneider Electric PLC M221 with RS485-BL == 565 565 566 566