Last modified by Karry Zhuang on 2024/07/11 11:58
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -20,7 +20,7 @@ 20 20 This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to Relay and VFD and communicate with Mobile. The structure is like below: 21 21 22 22 23 -[[image:image-20220527091852-1.png]] 23 +[[image:image-20220527091852-1.png||height="547" width="994"]] 24 24 25 25 Connection 26 26 ... ... @@ -45,13 +45,13 @@ 45 45 This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to Pulse Counter and communicate with Mobile. This example and example 2 compose the structure for a farm IoT solution. The structure is like below: 46 46 47 47 48 -[[image:image-20220527092058-3.png]] 48 +[[image:image-20220527092058-3.png||height="552" width="905"]] 49 49 50 50 Connection 51 51 52 52 53 53 54 -[[image:image-20220527092146-4.png]] 54 +[[image:image-20220527092146-4.png||height="507" width="906"]] 55 55 56 56 Connection 57 57 ... ... @@ -61,11 +61,9 @@ 61 61 * Configure Document: [[Pickdata MIO40 water pulse counter to LoRa with Dragino RS485-LN>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Pulse-Counter/||_mstmutation="1"]] 62 62 * [[Dragino Solution in Farm>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/&file=Dragino%20on%20Farms.pptx]] 63 63 64 +== **1.3 Example 3: Use RS485-LN with energy meters** == 64 64 65 65 66 -== **1.3 Example3: Use RS485-LN with energy meters** == 67 - 68 - 69 69 === **1.3.1 OverView** === 70 70 71 71 ... ... @@ -306,7 +306,7 @@ 306 306 ))) 307 307 308 308 ((( 309 -(% style="color: #4f81bd" %)**Type Code 0xAF**307 +(% style="color:blue" %)**Type Code 0xAF** 310 310 ))) 311 311 312 312 ((( ... ... @@ -469,6 +469,7 @@ 469 469 470 470 (% style="color:blue" %)**Example**(%%): These two meters are examples of setting parameters and device addresses. 471 471 470 + 472 472 [[image:image-20220527093950-25.png]] 473 473 474 474 ... ... @@ -532,6 +532,10 @@ 532 532 * 08 DF is the valid value of the meter with device address 02. 533 533 * 43 62 is the valid value of the meter with device address 01. 534 534 534 +(% style="display:none" %) (%%) 535 + 536 +(% style="display:none" %) (%%) 537 + 535 535 == 1.4 Example 4: Circuit Breaker Remote Open Close == 536 536 537 537 ... ... @@ -546,6 +546,7 @@ 546 546 547 547 * Configure Documen: [[Circuit Breaker Remote Open Close>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Circuit_Breaker_Remote_Open_Close/||_mstmutation="1"]] 548 548 552 + 549 549 == 1.5 Example 5: SEM Three Energy Meter with RS485-BL or RS485-LN == 550 550 551 551 ... ... @@ -554,6 +554,8 @@ 554 554 * Configure Document For RS485-BL: [[Connect to SEM Three>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/RS485-BL/Application_Note/&file=Dragino%20RS485BL%20and%20pickdata%20SEM%20Three%20v1.pdf||_mstmutation="1" style="background-color: rgb(255, 255, 255);"]] 555 555 * Configure Document for RS485-LN: [[Connect to SEM Three>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/SEM_Three_Energy_Meter/&file=SEM%20three%20and%20Dragino%20RS485-LN%20v1.pdf||_mstmutation="1"]] 556 556 561 + 562 + 557 557 == 1.6 Example 6: CEM C31 485-T1-MID Energy Meter with RS485-LN == 558 558 559 559 ... ... @@ -561,6 +561,8 @@ 561 561 562 562 * Configure Document For RS485-LN: [[CEM C31 485-T1-MID>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/ELECTRICAL%20CABINET/&file=ELECTRICAL%20CABINET%20READINGS.pdf||_mstmutation="1" style="background-color: rgb(255, 255, 255);"]] 563 563 570 + 571 + 564 564 == 1.7 Example 7: Schneider Electric PLC M221 with RS485-BL == 565 565 566 566