... ... @@ -75,6 +75,8 @@
75 75  
76 76  (((
77 77  This example describes a single-phase meter.This is the connection between the RS485-LN and the energy meter.
78 +
79 +
78 78  )))
79 79  
80 80  [[image:image-20220527092419-5.png]]
... ... @@ -177,6 +177,8 @@
177 177  
178 178  (((
179 179  If the configured parameters and commands are incorrect, the return value is not obtained.
182 +
183 +
180 180  )))
181 181  
182 182  [[image:image-20220601143201-9.png]]
... ... @@ -227,6 +227,7 @@
227 227  (((
228 228  (% style="color:blue" %)**Example**:
229 229  
234 +
230 230  (% style="color:red" %)**CMD1:**(%%) Read current data with MODBUS command. address: 0x03 AT+COMMAND1= 01 03 00 03 00 01,1
231 231  )))
232 232  
... ... @@ -268,6 +268,8 @@
268 268  
269 269  (((
270 270  Payload: 01 00 02 39 85 08 DC 00 00 00 44
276 +
277 +
271 271  )))
272 272  
273 273  [[image:image-20220601142936-6.png]]
... ... @@ -276,7 +276,7 @@
276 276  
277 277  
278 278  
279 -(% style="color:#4f81bd" %)**01 is device address,00 02 is the current, 08 DC is the voltage,00 00 00 44 is the total active energy.**
286 +(% style="color:blue" %)**01 is device address,00 02 is the current, 08 DC is the voltage,00 00 00 44 is the total active energy.**
280 280  
281 281  
282 282  [[image:image-20220601143642-2.png]]
... ... @@ -299,7 +299,7 @@
299 299  )))
300 300  
301 301  (((
302 -(% style="color:#4f81bd" %)**Type Code 0xAF**
309 +(% style="color:blue" %)**Type Code 0xAF**
303 303  )))
304 304  
305 305  (((
... ... @@ -462,6 +462,7 @@
462 462  
463 463  (% style="color:blue" %)**Example**(%%): These two meters are examples of setting parameters and device addresses.
464 464  
472 +
465 465  [[image:image-20220527093950-25.png]]
466 466  
467 467  
... ... @@ -525,6 +525,9 @@
525 525  * 08 DF is the valid value of the meter with device address 02.
526 526  * 43 62 is the valid value of the meter with device address 01.
527 527  
536 +
537 +
538 +
528 528  == 1.4 Example 4: Circuit Breaker Remote Open Close ==
529 529  
530 530  
... ... @@ -540,6 +540,8 @@
540 540  * Configure Documen:  [[Circuit Breaker Remote Open Close>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Circuit_Breaker_Remote_Open_Close/||_mstmutation="1"]]
541 541  
542 542  
554 +
555 +
543 543  == 1.5 Example 5: SEM Three Energy Meter with RS485-BL or RS485-LN ==
544 544  
545 545  
... ... @@ -549,6 +549,8 @@
549 549  * Configure Document for RS485-LN:  [[Connect to SEM Three>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/SEM_Three_Energy_Meter/&file=SEM%20three%20and%20Dragino%20RS485-LN%20v1.pdf||_mstmutation="1"]]
550 550  
551 551  
565 +
566 +
552 552  == 1.6 Example 6: CEM C31 485-T1-MID Energy Meter with RS485-LN ==
553 553  
554 554  
... ... @@ -557,6 +557,8 @@
557 557  * Configure Document For RS485-LN:  [[CEM C31 485-T1-MID>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/ELECTRICAL%20CABINET/&file=ELECTRICAL%20CABINET%20READINGS.pdf||_mstmutation="1" style="background-color: rgb(255, 255, 255);"]]
558 558  
559 559  
575 +
576 +
560 560  == 1.7 Example 7: Schneider Electric PLC M221 with RS485-BL ==
561 561  
562 562  