<
From version < 60.5 >
edited by Xiaoling
on 2022/08/11 16:59
To version < 60.7 >
edited by Xiaoling
on 2022/09/19 16:08
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -39,6 +39,7 @@
39 39  
40 40  
41 41  
42 +
42 42  == **1.2 Example 2: Connect to Pulse Counter** ==
43 43  
44 44  
... ... @@ -63,6 +63,7 @@
63 63  
64 64  
65 65  
67 +
66 66  == **1.3 Example3: Use RS485-LN with energy meters** ==
67 67  
68 68  
... ... @@ -75,6 +75,8 @@
75 75  
76 76  (((
77 77  This example describes a single-phase meter.This is the connection between the RS485-LN and the energy meter.
80 +
81 +
78 78  )))
79 79  
80 80  [[image:image-20220527092419-5.png]]
... ... @@ -177,6 +177,8 @@
177 177  
178 178  (((
179 179  If the configured parameters and commands are incorrect, the return value is not obtained.
184 +
185 +
180 180  )))
181 181  
182 182  [[image:image-20220601143201-9.png]]
... ... @@ -227,6 +227,7 @@
227 227  (((
228 228  (% style="color:blue" %)**Example**:
229 229  
236 +
230 230  (% style="color:red" %)**CMD1:**(%%) Read current data with MODBUS command. address: 0x03 AT+COMMAND1= 01 03 00 03 00 01,1
231 231  )))
232 232  
... ... @@ -268,6 +268,8 @@
268 268  
269 269  (((
270 270  Payload: 01 00 02 39 85 08 DC 00 00 00 44
278 +
279 +
271 271  )))
272 272  
273 273  [[image:image-20220601142936-6.png]]
... ... @@ -276,7 +276,7 @@
276 276  
277 277  
278 278  
279 -(% style="color:#4f81bd" %)**01 is device address,00 02 is the current, 08 DC is the voltage,00 00 00 44 is the total active energy.**
288 +(% style="color:blue" %)**01 is device address,00 02 is the current, 08 DC is the voltage,00 00 00 44 is the total active energy.**
280 280  
281 281  
282 282  [[image:image-20220601143642-2.png]]
... ... @@ -299,7 +299,7 @@
299 299  )))
300 300  
301 301  (((
302 -(% style="color:#4f81bd" %)**Type Code 0xAF**
311 +(% style="color:blue" %)**Type Code 0xAF**
303 303  )))
304 304  
305 305  (((
... ... @@ -539,7 +539,6 @@
539 539  
540 540  * Configure Documen:  [[Circuit Breaker Remote Open Close>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Circuit_Breaker_Remote_Open_Close/||_mstmutation="1"]]
541 541  
542 -
543 543  == 1.5 Example 5: SEM Three Energy Meter with RS485-BL or RS485-LN ==
544 544  
545 545  
... ... @@ -548,7 +548,6 @@
548 548  * Configure Document For RS485-BL:  [[Connect to SEM Three>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/RS485-BL/Application_Note/&file=Dragino%20RS485BL%20and%20pickdata%20SEM%20Three%20v1.pdf||_mstmutation="1" style="background-color: rgb(255, 255, 255);"]]
549 549  * Configure Document for RS485-LN:  [[Connect to SEM Three>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/SEM_Three_Energy_Meter/&file=SEM%20three%20and%20Dragino%20RS485-LN%20v1.pdf||_mstmutation="1"]]
550 550  
551 -
552 552  == 1.6 Example 6: CEM C31 485-T1-MID Energy Meter with RS485-LN ==
553 553  
554 554  
... ... @@ -556,7 +556,6 @@
556 556  
557 557  * Configure Document For RS485-LN:  [[CEM C31 485-T1-MID>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/ELECTRICAL%20CABINET/&file=ELECTRICAL%20CABINET%20READINGS.pdf||_mstmutation="1" style="background-color: rgb(255, 255, 255);"]]
558 558  
559 -
560 560  == 1.7 Example 7: Schneider Electric PLC M221 with RS485-BL ==
561 561  
562 562  
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0