Last modified by Karry Zhuang on 2024/07/11 11:58
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -13,11 +13,13 @@ 13 13 This article provide the examples for RS485-LN to connect to different type of RS485 sensors. 14 14 15 15 16 + 16 16 == **1.1 Example 1: Connect to Leak relay and VFD** == 17 17 18 18 19 19 This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to Relay and VFD and communicate with Mobile. The structure is like below: 20 20 22 + 21 21 [[image:image-20220527091852-1.png]] 22 22 23 23 Connection ... ... @@ -73,6 +73,8 @@ 73 73 74 74 ((( 75 75 This example describes a single-phase meter.This is the connection between the RS485-LN and the energy meter. 78 + 79 + 76 76 ))) 77 77 78 78 [[image:image-20220527092419-5.png]] ... ... @@ -175,6 +175,8 @@ 175 175 176 176 ((( 177 177 If the configured parameters and commands are incorrect, the return value is not obtained. 182 + 183 + 178 178 ))) 179 179 180 180 [[image:image-20220601143201-9.png]] ... ... @@ -225,6 +225,7 @@ 225 225 ((( 226 226 (% style="color:blue" %)**Example**: 227 227 234 + 228 228 (% style="color:red" %)**CMD1:**(%%) Read current data with MODBUS command. address: 0x03 AT+COMMAND1= 01 03 00 03 00 01,1 229 229 ))) 230 230 ... ... @@ -266,6 +266,8 @@ 266 266 267 267 ((( 268 268 Payload: 01 00 02 39 85 08 DC 00 00 00 44 276 + 277 + 269 269 ))) 270 270 271 271 [[image:image-20220601142936-6.png]] ... ... @@ -274,7 +274,7 @@ 274 274 275 275 276 276 277 -(% style="color: #4f81bd" %)**01 is device address,00 02 is the current, 08 DC is the voltage,00 00 00 44 is the total active energy.**286 +(% style="color:blue" %)**01 is device address,00 02 is the current, 08 DC is the voltage,00 00 00 44 is the total active energy.** 278 278 279 279 280 280 [[image:image-20220601143642-2.png]] ... ... @@ -297,7 +297,7 @@ 297 297 ))) 298 298 299 299 ((( 300 -(% style="color: #4f81bd" %)**Type Code 0xAF**309 +(% style="color:blue" %)**Type Code 0xAF** 301 301 ))) 302 302 303 303 ((( ... ... @@ -460,6 +460,7 @@ 460 460 461 461 (% style="color:blue" %)**Example**(%%): These two meters are examples of setting parameters and device addresses. 462 462 472 + 463 463 [[image:image-20220527093950-25.png]] 464 464 465 465 ... ... @@ -523,6 +523,9 @@ 523 523 * 08 DF is the valid value of the meter with device address 02. 524 524 * 43 62 is the valid value of the meter with device address 01. 525 525 536 + 537 + 538 + 526 526 == 1.4 Example 4: Circuit Breaker Remote Open Close == 527 527 528 528 ... ... @@ -539,6 +539,7 @@ 539 539 540 540 541 541 555 + 542 542 == 1.5 Example 5: SEM Three Energy Meter with RS485-BL or RS485-LN == 543 543 544 544 ... ... @@ -549,6 +549,7 @@ 549 549 550 550 551 551 566 + 552 552 == 1.6 Example 6: CEM C31 485-T1-MID Energy Meter with RS485-LN == 553 553 554 554 ... ... @@ -558,6 +558,7 @@ 558 558 559 559 560 560 576 + 561 561 == 1.7 Example 7: Schneider Electric PLC M221 with RS485-BL == 562 562 563 563