13 13  This article provide the examples for RS485-LN to connect to different type of RS485 sensors.
14 14  
15 15  
16 +
16 16  == **1.1 Example 1: Connect to Leak relay and VFD** ==
17 17  
18 18  
19 19  This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to Relay and VFD and communicate with Mobile. The structure is like below:
20 20  
22 +
21 21  [[image:image-20220527091852-1.png]]
22 22  
23 23  Connection
... ... @@ -70,11 +70,13 @@
70 70  
71 71  
72 72  (((
73 -(% style="color:red" %)**Note**:The specifications of each energy meter are different, please refer to your own energy meter specifications.
75 +(% style="color:red" %)**Note**:**The specifications of each energy meter are different, please refer to your own energy meter specifications.**
74 74  )))
75 75  
76 76  (((
77 77  This example describes a single-phase meter.This is the connection between the RS485-LN and the energy meter.
80 +
81 +
78 78  )))
79 79  
80 80  [[image:image-20220527092419-5.png]]
... ... @@ -177,6 +177,8 @@
177 177  
178 178  (((
179 179  If the configured parameters and commands are incorrect, the return value is not obtained.
184 +
185 +
180 180  )))
181 181  
182 182  [[image:image-20220601143201-9.png]]
... ... @@ -227,6 +227,7 @@
227 227  (((
228 228  (% style="color:blue" %)**Example**:
229 229  
236 +
230 230  (% style="color:red" %)**CMD1:**(%%) Read current data with MODBUS command. address: 0x03 AT+COMMAND1= 01 03 00 03 00 01,1
231 231  )))
232 232  
... ... @@ -268,6 +268,8 @@
268 268  
269 269  (((
270 270  Payload: 01 00 02 39 85 08 DC 00 00 00 44
278 +
279 +
271 271  )))
272 272  
273 273  [[image:image-20220601142936-6.png]]
... ... @@ -276,7 +276,7 @@
276 276  
277 277  
278 278  
279 -(% style="color:#4f81bd" %)**01 is device address,00 02 is the current, 08 DC is the voltage,00 00 00 44 is the total active energy.**
288 +(% style="color:blue" %)**01 is device address,00 02 is the current, 08 DC is the voltage,00 00 00 44 is the total active energy.**
280 280  
281 281  
282 282  [[image:image-20220601143642-2.png]]
... ... @@ -299,7 +299,7 @@
299 299  )))
300 300  
301 301  (((
302 -(% style="color:#4f81bd" %)**Type Code 0xAF**
311 +(% style="color:blue" %)**Type Code 0xAF**
303 303  )))
304 304  
305 305  (((
... ... @@ -525,9 +525,6 @@
525 525  * 08 DF is the valid value of the meter with device address 02.
526 526  * 43 62 is the valid value of the meter with device address 01.
527 527  
528 -
529 -
530 -
531 531  == 1.4 Example 4: Circuit Breaker Remote Open Close ==
532 532  
533 533  
... ... @@ -542,9 +542,6 @@
542 542  
543 543  * Configure Documen:  [[Circuit Breaker Remote Open Close>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Circuit_Breaker_Remote_Open_Close/||_mstmutation="1"]]
544 544  
545 -
546 -
547 -
548 548  == 1.5 Example 5: SEM Three Energy Meter with RS485-BL or RS485-LN ==
549 549  
550 550  
... ... @@ -553,9 +553,6 @@
553 553  * Configure Document For RS485-BL:  [[Connect to SEM Three>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/RS485-BL/Application_Note/&file=Dragino%20RS485BL%20and%20pickdata%20SEM%20Three%20v1.pdf||_mstmutation="1" style="background-color: rgb(255, 255, 255);"]]
554 554  * Configure Document for RS485-LN:  [[Connect to SEM Three>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/SEM_Three_Energy_Meter/&file=SEM%20three%20and%20Dragino%20RS485-LN%20v1.pdf||_mstmutation="1"]]
555 555  
556 -
557 -
558 -
559 559  == 1.6 Example 6: CEM C31 485-T1-MID Energy Meter with RS485-LN ==
560 560  
561 561  
... ... @@ -563,9 +563,6 @@
563 563  
564 564  * Configure Document For RS485-LN:  [[CEM C31 485-T1-MID>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/ELECTRICAL%20CABINET/&file=ELECTRICAL%20CABINET%20READINGS.pdf||_mstmutation="1" style="background-color: rgb(255, 255, 255);"]]
565 565  
566 -
567 -
568 -
569 569  == 1.7 Example 7: Schneider Electric PLC M221 with RS485-BL ==
570 570  
571 571  