Last modified by Karry Zhuang on 2024/07/11 11:58
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -7,26 +7,27 @@ 7 7 8 8 9 9 10 -= **1. Introduction**=10 += 1. Introduction = 11 11 12 12 13 13 This article provide the examples for RS485-LN to connect to different type of RS485 sensors. 14 14 15 15 16 -== **1.1 Example 1: Connect to Leak relay and VFD**==16 +== 1.1 Example 1: Connect to Leak relay and VFD == 17 17 18 18 19 19 This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to Relay and VFD and communicate with Mobile. The structure is like below: 20 20 21 -[[image:image-20220527091852-1.png]] 22 22 23 - Connection22 +[[image:image-20220527091852-1.png||height="547" width="994"]] 24 24 24 +**Connection** 25 25 26 26 27 + 27 27 [[image:image-20220527091942-2.png]](% style="display:none" %) 28 28 29 -Connection 30 +**Connection** 30 30 31 31 32 32 (% style="color:blue" %)**Related documents:** ... ... @@ -37,22 +37,21 @@ 37 37 38 38 39 39 41 +== 1.2 Example 2: Connect to Pulse Counter == 40 40 41 -== **1.2 Example 2: Connect to Pulse Counter** == 42 42 43 - 44 44 This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to Pulse Counter and communicate with Mobile. This example and example 2 compose the structure for a farm IoT solution. The structure is like below: 45 45 46 46 47 -[[image:image-20220527092058-3.png]] 47 +[[image:image-20220527092058-3.png||height="552" width="905"]] 48 48 49 -Connection 49 +**Connection** 50 50 51 51 52 52 53 -[[image:image-20220527092146-4.png]] 53 +[[image:image-20220527092146-4.png||height="507" width="906"]] 54 54 55 -Connection 55 +**Connection** 56 56 57 57 58 58 (% style="color:blue" %)**Related documents:** ... ... @@ -62,24 +62,24 @@ 62 62 63 63 64 64 65 +== 1.3 Example 3: Use RS485-LN with energy meters == 65 65 66 -== **1.3Example3: UseRS485-LNwithenergy meters**==67 +=== 1.3.1 OverView === 67 67 68 68 69 -=== **1.3.1 OverView** === 70 - 71 - 72 72 ((( 73 -(% style="color:red" %)**Note**:The specifications of each energy meter are different, please refer to your own energy meter specifications. 71 +(% style="color:red" %)**Note**:**The specifications of each energy meter are different, please refer to your own energy meter specifications.** 74 74 ))) 75 75 76 76 ((( 77 77 This example describes a single-phase meter.This is the connection between the RS485-LN and the energy meter. 76 + 77 + 78 78 ))) 79 79 80 80 [[image:image-20220527092419-5.png]] 81 81 82 -Connection1 82 +**Connection1** 83 83 84 84 85 85 ... ... @@ -113,19 +113,18 @@ 113 113 114 114 [[image:image-20220527092514-6.png]] 115 115 116 -Connection2 116 +**Connection2** 117 117 118 118 119 119 120 120 [[image:image-20220527092555-7.png]] 121 121 122 -Connection3 122 +**Connection3** 123 123 124 124 125 +=== 1.3.2 How to use the parameters of the energy meter and MODBUS commands === 125 125 126 -=== **1.3.2 How to use the parameters of the energy meter and MODBUS commands** === 127 127 128 - 129 129 If the user needs to read the parameters of the electric energy meter and use the modbus command,please refer to the appendix of the MODBUS communication protocol in the user manual of the energy meter. 130 130 131 131 [[image:image-20220601143257-10.png]] ... ... @@ -159,29 +159,29 @@ 159 159 ((( 160 160 161 161 162 - 163 163 164 164 ))) 165 165 166 -=== **1.3.3 How to configure RS485-LN and parse output commands**===164 +=== 1.3.3 How to configure RS485-LN and parse output commands === 167 167 168 168 169 169 RS485-LN provides two configuration methods: AT COMMAND and DOWNLINK. 170 170 171 171 170 +==== 1.3.3.1 via AT COMMAND ==== 172 172 173 -==== **1.3.3.1 via AT COMMAND** ==== 174 174 175 - 176 176 First, we can use (% style="color:blue" %)**AT+CFGDEV**(%%) to get the return value, and we can also judge whether the input parameters are correct. 177 177 178 178 ((( 179 179 If the configured parameters and commands are incorrect, the return value is not obtained. 177 + 178 + 180 180 ))) 181 181 182 182 [[image:image-20220601143201-9.png]] 183 183 184 -AT COMMAND 183 +**AT COMMAND** 185 185 186 186 187 187 (% class="box infomessage" %) ... ... @@ -197,16 +197,15 @@ 197 197 198 198 [[image:image-20220601143115-8.png]] 199 199 200 -AT COMMAND 199 +**AT COMMAND** 201 201 202 202 203 203 204 204 PAYLOAD is available after the valid value is intercepted. 205 205 206 - 207 207 [[image:image-20220601143046-7.png]] 208 208 209 -AT COMMAND 207 +**AT COMMAND** 210 210 211 211 212 212 ... ... @@ -215,18 +215,17 @@ 215 215 [[image:image-20220601143519-1.png]] 216 216 217 217 ((( 218 -AT COMMAND 216 +**AT COMMAND** 219 219 ))) 220 220 221 221 ((( 222 222 223 - 224 - 225 225 ))) 226 226 227 227 ((( 228 228 (% style="color:blue" %)**Example**: 229 229 226 + 230 230 (% style="color:red" %)**CMD1:**(%%) Read current data with MODBUS command. address: 0x03 AT+COMMAND1= 01 03 00 03 00 01,1 231 231 ))) 232 232 ... ... @@ -268,6 +268,8 @@ 268 268 269 269 ((( 270 270 Payload: 01 00 02 39 85 08 DC 00 00 00 44 268 + 269 + 271 271 ))) 272 272 273 273 [[image:image-20220601142936-6.png]] ... ... @@ -276,7 +276,7 @@ 276 276 277 277 278 278 279 -(% style="color: #4f81bd" %)**01 is device address,00 02 is the current, 08 DC is the voltage,00 00 00 44 is the total active energy.**278 +(% style="color:blue" %)**01 is device address,00 02 is the current, 08 DC is the voltage,00 00 00 44 is the total active energy.** 280 280 281 281 282 282 [[image:image-20220601143642-2.png]] ... ... @@ -285,13 +285,13 @@ 285 285 286 286 287 287 288 -==== **1.3.3.2 via LoRaWAN DOWNLINK**====287 +==== 1.3.3.2 via LoRaWAN DOWNLINK ==== 289 289 290 290 291 291 [[image:image-20220527093358-15.png]] 292 292 293 293 ((( 294 -DOWNLINK 293 +**DOWNLINK** 295 295 ))) 296 296 297 297 ((( ... ... @@ -299,7 +299,7 @@ 299 299 ))) 300 300 301 301 ((( 302 -(% style="color: #4f81bd" %)**Type Code 0xAF**301 +(% style="color:blue" %)**Type Code 0xAF** 303 303 ))) 304 304 305 305 ((( ... ... @@ -359,35 +359,34 @@ 359 359 360 360 [[image:image-20220601144149-6.png]] 361 361 362 -DOWNLINK 361 +**DOWNLINK** 363 363 364 364 365 365 366 366 [[image:image-20220601143803-3.png]] 367 367 368 -DOWNLINK 367 +**DOWNLINK** 369 369 370 370 371 371 372 372 [[image:image-20220601144053-5.png]] 373 373 374 -DOWNLINK 373 +**DOWNLINK** 375 375 376 376 377 377 378 378 [[image:image-20220601143921-4.png]] 379 379 380 -DOWNLINK 379 +**DOWNLINK** 381 381 382 382 383 383 384 384 [[image:image-20220601142805-5.png]] 385 385 386 -DOWNLINK 387 - 385 +**DOWNLINK** 388 388 389 389 390 -=== **1.3.4 How to configure and output commands for RS485 to USB**===388 +=== 1.3.4 How to configure and output commands for RS485 to USB === 391 391 392 392 393 393 ((( ... ... @@ -414,13 +414,13 @@ 414 414 415 415 [[image:image-20220527093708-21.png]] 416 416 417 -USB 415 +**USB** 418 418 419 419 420 420 421 421 [[image:image-20220527093747-22.png]] 422 422 423 -USB 421 +**USB** 424 424 425 425 426 426 ... ... @@ -442,11 +442,11 @@ 442 442 443 443 [[image:image-20220527093821-23.png]] 444 444 445 -USB 443 +**USB** 446 446 447 447 448 448 449 -=== **1.3.5 How to configure multiple devices and modify device addresses**===447 +=== 1.3.5 How to configure multiple devices and modify device addresses === 450 450 451 451 452 452 If users need to read the parameters of multiple energy meters, they need to modify the device address, because the default device address of each energy meter is 01. ... ... @@ -462,6 +462,7 @@ 462 462 463 463 (% style="color:blue" %)**Example**(%%): These two meters are examples of setting parameters and device addresses. 464 464 463 + 465 465 [[image:image-20220527093950-25.png]] 466 466 467 467 ... ... @@ -494,9 +494,9 @@ 494 494 **AT+CFGDEV:01 10 00 61 00 01 02 00 02,1** 495 495 ))) 496 496 497 -* 01:device adaress 496 +* 01: device adaress 498 498 499 -* 10:function code 498 +* 10: function code 500 500 501 501 * 00 61:Register address 502 502 ... ... @@ -525,9 +525,10 @@ 525 525 * 08 DF is the valid value of the meter with device address 02. 526 526 * 43 62 is the valid value of the meter with device address 01. 527 527 527 +(% style="display:none" %) (%%) 528 528 529 +(% style="display:none" %) (%%) 529 529 530 - 531 531 == 1.4 Example 4: Circuit Breaker Remote Open Close == 532 532 533 533 ... ... @@ -544,7 +544,6 @@ 544 544 545 545 546 546 547 - 548 548 == 1.5 Example 5: SEM Three Energy Meter with RS485-BL or RS485-LN == 549 549 550 550 ... ... @@ -555,7 +555,6 @@ 555 555 556 556 557 557 558 - 559 559 == 1.6 Example 6: CEM C31 485-T1-MID Energy Meter with RS485-LN == 560 560 561 561 ... ... @@ -565,7 +565,6 @@ 565 565 566 566 567 567 568 - 569 569 == 1.7 Example 7: Schneider Electric PLC M221 with RS485-BL == 570 570 571 571