13 13  This article provide the examples for RS485-LN to connect to different type of RS485 sensors.
14 14  
15 15  
16 +
16 16  == **1.1 Example 1: Connect to Leak relay and VFD** ==
17 17  
18 18  
19 19  This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to Relay and VFD and communicate with Mobile. The structure is like below:
20 20  
21 -[[image:image-20220527091852-1.png]]
22 22  
23 +[[image:image-20220527091852-1.png||height="547" width="994"]]
24 +
23 23  Connection
24 24  
25 25  
... ... @@ -44,13 +44,13 @@
44 44  This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to Pulse Counter and communicate with Mobile. This example and example 2 compose the structure for a farm IoT solution. The structure is like below:
45 45  
46 46  
47 -[[image:image-20220527092058-3.png]]
49 +[[image:image-20220527092058-3.png||height="552" width="905"]]
48 48  
49 49  Connection
50 50  
51 51  
52 52  
53 -[[image:image-20220527092146-4.png]]
55 +[[image:image-20220527092146-4.png||height="507" width="906"]]
54 54  
55 55  Connection
56 56  
... ... @@ -61,8 +61,6 @@
61 61  * [[Dragino Solution in Farm>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/&file=Dragino%20on%20Farms.pptx]]
62 62  
63 63  
64 -
65 -
66 66  == **1.3 Example3: Use RS485-LN with energy meters** ==
67 67  
68 68  
... ... @@ -70,11 +70,13 @@
70 70  
71 71  
72 72  (((
73 -(% style="color:red" %)**Note**:The specifications of each energy meter are different, please refer to your own energy meter specifications.
73 +(% style="color:red" %)**Note**:**The specifications of each energy meter are different, please refer to your own energy meter specifications.**
74 74  )))
75 75  
76 76  (((
77 77  This example describes a single-phase meter.This is the connection between the RS485-LN and the energy meter.
78 +
79 +
78 78  )))
79 79  
80 80  [[image:image-20220527092419-5.png]]
... ... @@ -177,6 +177,8 @@
177 177  
178 178  (((
179 179  If the configured parameters and commands are incorrect, the return value is not obtained.
182 +
183 +
180 180  )))
181 181  
182 182  [[image:image-20220601143201-9.png]]
... ... @@ -227,6 +227,7 @@
227 227  (((
228 228  (% style="color:blue" %)**Example**:
229 229  
234 +
230 230  (% style="color:red" %)**CMD1:**(%%) Read current data with MODBUS command. address: 0x03 AT+COMMAND1= 01 03 00 03 00 01,1
231 231  )))
232 232  
... ... @@ -268,6 +268,8 @@
268 268  
269 269  (((
270 270  Payload: 01 00 02 39 85 08 DC 00 00 00 44
276 +
277 +
271 271  )))
272 272  
273 273  [[image:image-20220601142936-6.png]]
... ... @@ -276,7 +276,7 @@
276 276  
277 277  
278 278  
279 -(% style="color:#4f81bd" %)**01 is device address,00 02 is the current, 08 DC is the voltage,00 00 00 44 is the total active energy.**
286 +(% style="color:blue" %)**01 is device address,00 02 is the current, 08 DC is the voltage,00 00 00 44 is the total active energy.**
280 280  
281 281  
282 282  [[image:image-20220601143642-2.png]]
... ... @@ -299,7 +299,7 @@
299 299  )))
300 300  
301 301  (((
302 -(% style="color:#4f81bd" %)**Type Code 0xAF**
309 +(% style="color:blue" %)**Type Code 0xAF**
303 303  )))
304 304  
305 305  (((
... ... @@ -462,6 +462,7 @@
462 462  
463 463  (% style="color:blue" %)**Example**(%%): These two meters are examples of setting parameters and device addresses.
464 464  
472 +
465 465  [[image:image-20220527093950-25.png]]
466 466  
467 467  
... ... @@ -525,6 +525,11 @@
525 525  * 08 DF is the valid value of the meter with device address 02.
526 526  * 43 62 is the valid value of the meter with device address 01.
527 527  
536 +(% style="display:none" %) (%%)
537 +
538 +(% style="display:none" %) (%%)
539 +
540 +
528 528  == 1.4 Example 4: Circuit Breaker Remote Open Close ==
529 529  
530 530  
... ... @@ -539,6 +539,8 @@
539 539  
540 540  * Configure Documen:  [[Circuit Breaker Remote Open Close>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Circuit_Breaker_Remote_Open_Close/||_mstmutation="1"]]
541 541  
555 +
556 +
542 542  == 1.5 Example 5: SEM Three Energy Meter with RS485-BL or RS485-LN ==
543 543  
544 544  
... ... @@ -547,6 +547,9 @@
547 547  * Configure Document For RS485-BL:  [[Connect to SEM Three>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/RS485-BL/Application_Note/&file=Dragino%20RS485BL%20and%20pickdata%20SEM%20Three%20v1.pdf||_mstmutation="1" style="background-color: rgb(255, 255, 255);"]]
548 548  * Configure Document for RS485-LN:  [[Connect to SEM Three>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/SEM_Three_Energy_Meter/&file=SEM%20three%20and%20Dragino%20RS485-LN%20v1.pdf||_mstmutation="1"]]
549 549  
565 +
566 +
567 +
550 550  == 1.6 Example 6: CEM C31 485-T1-MID Energy Meter with RS485-LN ==
551 551  
552 552  
... ... @@ -554,6 +554,9 @@
554 554  
555 555  * Configure Document For RS485-LN:  [[CEM C31 485-T1-MID>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/ELECTRICAL%20CABINET/&file=ELECTRICAL%20CABINET%20READINGS.pdf||_mstmutation="1" style="background-color: rgb(255, 255, 255);"]]
556 556  
575 +
576 +
577 +
557 557  == 1.7 Example 7: Schneider Electric PLC M221 with RS485-BL ==
558 558  