<
From version < 60.13 >
edited by Xiaoling
on 2023/04/20 10:19
To version < 62.1 >
edited by Bei Jinggeng
on 2023/08/08 15:23
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Xiaoling
1 +XWiki.Bei
Content
... ... @@ -38,8 +38,6 @@
38 38  
39 39  * [[Video Demo>>url:https://www.youtube.com/watch?v=TAFZ5eaf-MY&t=6s&ab_channel=XavierFlorensaBerenguer]]
40 40  
41 -
42 -
43 43  == 1.2 Example 2: Connect to Pulse Counter ==
44 44  
45 45  
... ... @@ -63,8 +63,6 @@
63 63  
64 64  * [[Dragino Solution in Farm>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/&file=Dragino%20on%20Farms.pptx]]
65 65  
66 -
67 -
68 68  == 1.3 Example 3: Use RS485-LN with energy meters ==
69 69  
70 70  === 1.3.1 OverView ===
... ... @@ -166,8 +166,6 @@
166 166  
167 167  * 08 FD is register data. Use short integer 16 bits to convert to decimal, get 2301, then 230.1V is the voltage.
168 168  
169 -
170 -
171 171  === 1.3.3 How to configure RS485-LN and parse output commands ===
172 172  
173 173  
... ... @@ -538,8 +538,6 @@
538 538  
539 539  * Configure Documen:  [[Circuit Breaker Remote Open Close>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Circuit_Breaker_Remote_Open_Close/||_mstmutation="1"]]
540 540  
541 -
542 -
543 543  == 1.5 Example 5: SEM Three Energy Meter with RS485-BL or RS485-LN ==
544 544  
545 545  
... ... @@ -549,8 +549,6 @@
549 549  
550 550  * Configure Document for RS485-LN:  [[Connect to SEM Three>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/SEM_Three_Energy_Meter/&file=SEM%20three%20and%20Dragino%20RS485-LN%20v1.pdf||_mstmutation="1"]]
551 551  
552 -
553 -
554 554  == 1.6 Example 6: CEM C31 485-T1-MID Energy Meter with RS485-LN ==
555 555  
556 556  
... ... @@ -558,14 +558,24 @@
558 558  
559 559  * Configure Document For RS485-LN:  [[CEM C31 485-T1-MID>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/ELECTRICAL%20CABINET/&file=ELECTRICAL%20CABINET%20READINGS.pdf||_mstmutation="1" style="background-color: rgb(255, 255, 255);"]]
560 560  
561 -
562 -
563 563  == 1.7 Example 7: Schneider Electric PLC M221 with RS485-BL ==
564 564  
565 565  
566 566  [[image:image-20220527094556-31.png]]
567 567  
556 +
568 568  Network Structure
569 569  
570 -
571 571  * [[Reference Instruction>>url:https://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Schneider%20Electric%20PLC/]]
560 +
561 +== 1.8  Example 8: This sketch is supposed to test Dragino RS485-BL (Modbus master), using an Arduino UNO as a Modbus slave. ==
562 +
563 +This sketch uses 4 registers: some of them can be set by Dragino with a command, another is used to store value from a DS18B20 temperature sensor, or a random generated number. All data is 16bit uint, but the sketch shows also how to represent booleans and negative numbers.
564 +
565 +In the next days I will be adding more documentation, but I think it already explains users how to build their own modbus sensor to pair with Dragino RS485-BL.
566 +
567 +This is released the code under GNU LGPL licence on Github:
568 +
569 +[[https:~~/~~/github.com/zorbaproject/ArduinoModbusForDraginoRS485>>url:https://github.com/zorbaproject/ArduinoModbusForDraginoRS485]]
570 +
571 +
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0