Last modified by Karry Zhuang on 2024/07/11 11:58
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -7,28 +7,27 @@ 7 7 8 8 9 9 10 -= **1. Introduction**=10 += 1. Introduction = 11 11 12 12 13 13 This article provide the examples for RS485-LN to connect to different type of RS485 sensors. 14 14 15 15 16 +== 1.1 Example 1: Connect to Leak relay and VFD == 16 16 17 -== **1.1 Example 1: Connect to Leak relay and VFD** == 18 18 19 - 20 20 This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to Relay and VFD and communicate with Mobile. The structure is like below: 21 21 22 22 23 23 [[image:image-20220527091852-1.png||height="547" width="994"]] 24 24 25 -Connection 24 +**Connection** 26 26 27 27 28 28 29 29 [[image:image-20220527091942-2.png]](% style="display:none" %) 30 30 31 -Connection 30 +**Connection** 32 32 33 33 34 34 (% style="color:blue" %)**Related documents:** ... ... @@ -39,7 +39,7 @@ 39 39 40 40 41 41 42 -== **1.2 Example 2: Connect to Pulse Counter**==41 +== 1.2 Example 2: Connect to Pulse Counter == 43 43 44 44 45 45 This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to Pulse Counter and communicate with Mobile. This example and example 2 compose the structure for a farm IoT solution. The structure is like below: ... ... @@ -47,13 +47,13 @@ 47 47 48 48 [[image:image-20220527092058-3.png||height="552" width="905"]] 49 49 50 -Connection 49 +**Connection** 51 51 52 52 53 53 54 54 [[image:image-20220527092146-4.png||height="507" width="906"]] 55 55 56 -Connection 55 +**Connection** 57 57 58 58 59 59 (% style="color:blue" %)**Related documents:** ... ... @@ -61,12 +61,13 @@ 61 61 * Configure Document: [[Pickdata MIO40 water pulse counter to LoRa with Dragino RS485-LN>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Pulse-Counter/||_mstmutation="1"]] 62 62 * [[Dragino Solution in Farm>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/&file=Dragino%20on%20Farms.pptx]] 63 63 64 -== **1.3 Example 3: Use RS485-LN with energy meters** == 65 65 66 66 67 -== =**1.3.1OverView**===65 +== 1.3 Example 3: Use RS485-LN with energy meters == 68 68 67 +=== 1.3.1 OverView === 69 69 69 + 70 70 ((( 71 71 (% style="color:red" %)**Note**:**The specifications of each energy meter are different, please refer to your own energy meter specifications.** 72 72 ))) ... ... @@ -79,7 +79,7 @@ 79 79 80 80 [[image:image-20220527092419-5.png]] 81 81 82 -Connection1 82 +**Connection1** 83 83 84 84 85 85 ... ... @@ -113,19 +113,18 @@ 113 113 114 114 [[image:image-20220527092514-6.png]] 115 115 116 -Connection2 116 +**Connection2** 117 117 118 118 119 119 120 120 [[image:image-20220527092555-7.png]] 121 121 122 -Connection3 122 +**Connection3** 123 123 124 124 125 +=== 1.3.2 How to use the parameters of the energy meter and MODBUS commands === 125 125 126 -=== **1.3.2 How to use the parameters of the energy meter and MODBUS commands** === 127 127 128 - 129 129 If the user needs to read the parameters of the electric energy meter and use the modbus command,please refer to the appendix of the MODBUS communication protocol in the user manual of the energy meter. 130 130 131 131 [[image:image-20220601143257-10.png]] ... ... @@ -159,20 +159,18 @@ 159 159 ((( 160 160 161 161 162 - 163 163 164 164 ))) 165 165 166 -=== **1.3.3 How to configure RS485-LN and parse output commands**===164 +=== 1.3.3 How to configure RS485-LN and parse output commands === 167 167 168 168 169 169 RS485-LN provides two configuration methods: AT COMMAND and DOWNLINK. 170 170 171 171 170 +==== 1.3.3.1 via AT COMMAND ==== 172 172 173 -==== **1.3.3.1 via AT COMMAND** ==== 174 174 175 - 176 176 First, we can use (% style="color:blue" %)**AT+CFGDEV**(%%) to get the return value, and we can also judge whether the input parameters are correct. 177 177 178 178 ((( ... ... @@ -183,7 +183,7 @@ 183 183 184 184 [[image:image-20220601143201-9.png]] 185 185 186 -AT COMMAND 183 +**AT COMMAND** 187 187 188 188 189 189 (% class="box infomessage" %) ... ... @@ -199,16 +199,15 @@ 199 199 200 200 [[image:image-20220601143115-8.png]] 201 201 202 -AT COMMAND 199 +**AT COMMAND** 203 203 204 204 205 205 206 206 PAYLOAD is available after the valid value is intercepted. 207 207 208 - 209 209 [[image:image-20220601143046-7.png]] 210 210 211 -AT COMMAND 207 +**AT COMMAND** 212 212 213 213 214 214 ... ... @@ -217,13 +217,11 @@ 217 217 [[image:image-20220601143519-1.png]] 218 218 219 219 ((( 220 -AT COMMAND 216 +**AT COMMAND** 221 221 ))) 222 222 223 223 ((( 224 224 225 - 226 - 227 227 ))) 228 228 229 229 ((( ... ... @@ -290,13 +290,13 @@ 290 290 291 291 292 292 293 -==== **1.3.3.2 via LoRaWAN DOWNLINK**====287 +==== 1.3.3.2 via LoRaWAN DOWNLINK ==== 294 294 295 295 296 296 [[image:image-20220527093358-15.png]] 297 297 298 298 ((( 299 -DOWNLINK 293 +**DOWNLINK** 300 300 ))) 301 301 302 302 ((( ... ... @@ -364,35 +364,34 @@ 364 364 365 365 [[image:image-20220601144149-6.png]] 366 366 367 -DOWNLINK 361 +**DOWNLINK** 368 368 369 369 370 370 371 371 [[image:image-20220601143803-3.png]] 372 372 373 -DOWNLINK 367 +**DOWNLINK** 374 374 375 375 376 376 377 377 [[image:image-20220601144053-5.png]] 378 378 379 -DOWNLINK 373 +**DOWNLINK** 380 380 381 381 382 382 383 383 [[image:image-20220601143921-4.png]] 384 384 385 -DOWNLINK 379 +**DOWNLINK** 386 386 387 387 388 388 389 389 [[image:image-20220601142805-5.png]] 390 390 391 -DOWNLINK 392 - 385 +**DOWNLINK** 393 393 394 394 395 -=== **1.3.4 How to configure and output commands for RS485 to USB**===388 +=== 1.3.4 How to configure and output commands for RS485 to USB === 396 396 397 397 398 398 ((( ... ... @@ -419,13 +419,13 @@ 419 419 420 420 [[image:image-20220527093708-21.png]] 421 421 422 -USB 415 +**USB** 423 423 424 424 425 425 426 426 [[image:image-20220527093747-22.png]] 427 427 428 -USB 421 +**USB** 429 429 430 430 431 431 ... ... @@ -447,11 +447,11 @@ 447 447 448 448 [[image:image-20220527093821-23.png]] 449 449 450 -USB 443 +**USB** 451 451 452 452 453 453 454 -=== **1.3.5 How to configure multiple devices and modify device addresses**===447 +=== 1.3.5 How to configure multiple devices and modify device addresses === 455 455 456 456 457 457 If users need to read the parameters of multiple energy meters, they need to modify the device address, because the default device address of each energy meter is 01. ... ... @@ -500,9 +500,9 @@ 500 500 **AT+CFGDEV:01 10 00 61 00 01 02 00 02,1** 501 501 ))) 502 502 503 -* 01:device adaress 496 +* 01: device adaress 504 504 505 -* 10:function code 498 +* 10: function code 506 506 507 507 * 00 61:Register address 508 508 ... ... @@ -550,6 +550,7 @@ 550 550 * Configure Documen: [[Circuit Breaker Remote Open Close>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Circuit_Breaker_Remote_Open_Close/||_mstmutation="1"]] 551 551 552 552 546 + 553 553 == 1.5 Example 5: SEM Three Energy Meter with RS485-BL or RS485-LN == 554 554 555 555