From version < 60.1 >
edited by Bei Jinggeng
on 2022/07/14 17:16
To version < 57.16 >
edited by Xiaoling
on 2022/07/14 09:55
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Bei
1 +XWiki.Xiaoling
Content
... ... @@ -31,11 +31,12 @@
31 31  
32 32  (% style="color:blue" %)**Related documents:**
33 33  
34 -* System Structure:  [[Solar Pump with Dragino>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Relay_VFD/||_mstmutation="1" style="background-color: rgb(255, 255, 255);"]]
35 -* Explanation on how to integrate to Node-red and to the Mobile Phone, and with link to the Github code:  [[Configure Manual>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Relay_VFD/||_mstmutation="1" style="background-color: rgb(255, 255, 255);"]]
34 +* System Structure:  [[Solar Pump with Dragino>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Relay_VFD/||style="background-color: rgb(255, 255, 255);"]]
35 +* Explanation on how to integrate to Node-red and to the Mobile Phone, and with link to the Github code:  [[Configure Manual>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Relay_VFD/||style="background-color: rgb(255, 255, 255);"]]
36 36  * [[Video Demo>>url:https://www.youtube.com/watch?v=TAFZ5eaf-MY&t=6s&ab_channel=XavierFlorensaBerenguer]]
37 37  
38 38  
39 +
39 39  == **1.2 Example 2: Connect to Pulse Counter** ==
40 40  
41 41  
... ... @@ -55,10 +55,12 @@
55 55  
56 56  (% style="color:blue" %)**Related documents:**
57 57  
58 -* Configure Document:  [[Pickdata MIO40 water pulse counter to LoRa with Dragino RS485-LN>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Pulse-Counter/||_mstmutation="1"]]
59 +* Configure Document:  [[Pickdata MIO40 water pulse counter to LoRa with Dragino RS485-LN>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Pulse-Counter/]]
59 59  * [[Dragino Solution in Farm>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/&file=Dragino%20on%20Farms.pptx]]
60 60  
61 61  
63 +
64 +
62 62  == **1.3 Example3: Use RS485-LN with energy meters** ==
63 63  
64 64  
... ... @@ -110,12 +110,12 @@
110 110  Connection2
111 111  
112 112  
116 +
113 113  [[image:image-20220527092555-7.png]]
114 114  
115 115  Connection3
116 116  
117 117  
118 -
119 119  === **1.3.2 How to use the parameters of the energy meter and MODBUS commands** ===
120 120  
121 121  
... ... @@ -162,7 +162,6 @@
162 162  RS485-LN provides two configuration methods: AT COMMAND and DOWNLINK.
163 163  
164 164  
165 -
166 166  ==== **1.3.3.1 via AT COMMAND** ====
167 167  
168 168  
... ... @@ -179,7 +179,7 @@
179 179  
180 180  (% class="box infomessage" %)
181 181  (((
182 - (% _mstmutation="1" %)**AT+DATACUTx **(%%):  This command defines how to handle the return from AT+COMMANDx, max reture length is 40 bytes. AT+DATACUTx=a,b,c
184 + **AT+DATACUTx **:  This command defines how to handle the return from AT+COMMANDx, max reture length is 40 bytes. AT+DATACUTx=a,b,c
183 183  )))
184 184  
185 185  a:  length for the return of AT+COMMAND
... ... @@ -218,7 +218,7 @@
218 218  (((
219 219  (% style="color:blue" %)**Example**:
220 220  
221 -(% style="color:red" %)**CMD1:**(%%) Read current data with MODBUS command. address: 0x03 AT+COMMAND1= 01 03 00 03 00 01,1
223 +CMD1: Read current data with MODBUS command. address: 0x03 AT+COMMAND1= 01 03 00 03 00 01,1
222 222  )))
223 223  
224 224  (((
... ... @@ -232,7 +232,7 @@
232 232  )))
233 233  
234 234  (((
235 -(% style="color:red" %)**CMD2: **(%%)Read voltage data with MODBUS command. address: 0x00 AT+COMMAND2= 01 03 00 00 00 01,1
237 +CMD2: Read voltage data with MODBUS command. address: 0x00 AT+COMMAND2= 01 03 00 00 00 01,1
236 236  )))
237 237  
238 238  (((
... ... @@ -246,7 +246,7 @@
246 246  )))
247 247  
248 248  (((
249 -(% style="color:red" %)**CMD3:**(%%) Read total active energy data with MODBUS command. address: 0x0031 AT+COMMAND3= 01 03 00 31 00 02,1
251 +CMD3: Read total active energy data with MODBUS command. address: 0x0031 AT+COMMAND3= 01 03 00 31 00 02,1
250 250  )))
251 251  
252 252  (((
... ... @@ -274,7 +274,6 @@
274 274  AT COMMAND
275 275  
276 276  
277 -
278 278  ==== **1.3.3.2 via LoRaWAN DOWNLINK** ====
279 279  
280 280  
... ... @@ -300,7 +300,7 @@
300 300  )))
301 301  
302 302  (((
303 -(% style="color:red" %)**Note: if user use AT+COMMANDx to add a new command, he also need to send AT+DATACUTx downlink.**
304 +(% style="color:red" %)Note: if user use AT+COMMANDx to add a new command, he also need to send AT+DATACUTx downlink.
304 304  )))
305 305  
306 306  (((
... ... @@ -374,7 +374,6 @@
374 374  DOWNLINK
375 375  
376 376  
377 -
378 378  === **1.3.4 How to configure and output commands for RS485 to USB** ===
379 379  
380 380  (((
... ... @@ -432,7 +432,6 @@
432 432  USB
433 433  
434 434  
435 -
436 436  === **1.3.5 How to configure multiple devices and modify device addresses** ===
437 437  
438 438  
... ... @@ -463,7 +463,7 @@
463 463  
464 464  (((
465 465  (((
466 -We can use (% style="color:blue" %)**AT+CFGDEV**(%%) to set the device address.
465 +We can use **AT+CFGDEV** to set the device address.
467 467  )))
468 468  )))
469 469  
... ... @@ -507,12 +507,13 @@
507 507  [[image:image-20220601142607-4.png]]
508 508  
509 509  
510 -(% style="color:blue" %)**PAYLOAD: 01 08 DF 43 62**
509 +**PAYLOAD:01 08 DF 43 62**
511 511  
512 512  * 08 DF is the valid value of the meter with device address 02.
513 513  * 43 62 is the valid value of the meter with device address 01.
514 514  
515 515  
515 +
516 516  == 1.4 Example 4: Circuit Breaker Remote Open Close ==
517 517  
518 518  
... ... @@ -525,26 +525,29 @@
525 525  Connection
526 526  
527 527  
528 -* Configure Documen:  [[Circuit Breaker Remote Open Close>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Circuit_Breaker_Remote_Open_Close/||_mstmutation="1"]]
528 +* Configure Documen:  [[Circuit Breaker Remote Open Close>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Circuit_Breaker_Remote_Open_Close/]]
529 529  
530 530  
531 +
531 531  == 1.5 Example 5: SEM Three Energy Meter with RS485-BL or RS485-LN ==
532 532  
533 533  
534 534  This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-BL to connect to SEM Three Energy Meter and send the data to mobile phone for remote minitor. The structure is like below:
535 535  
536 -* Configure Document For RS485-BL:  [[Connect to SEM Three>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/RS485-BL/Application_Note/&file=Dragino%20RS485BL%20and%20pickdata%20SEM%20Three%20v1.pdf||_mstmutation="1" style="background-color: rgb(255, 255, 255);"]]
537 -* Configure Document for RS485-LN:  [[Connect to SEM Three>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/SEM_Three_Energy_Meter/&file=SEM%20three%20and%20Dragino%20RS485-LN%20v1.pdf||_mstmutation="1"]]
537 +* Configure Document For RS485-BL:  [[Connect to SEM Three>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/RS485-BL/Application_Note/&file=Dragino%20RS485BL%20and%20pickdata%20SEM%20Three%20v1.pdf||style="background-color: rgb(255, 255, 255);"]]
538 +* Configure Document for RS485-LN:  [[Connect to SEM Three>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/SEM_Three_Energy_Meter/&file=SEM%20three%20and%20Dragino%20RS485-LN%20v1.pdf]]
538 538  
539 539  
541 +
540 540  == 1.6 Example 6: CEM C31 485-T1-MID Energy Meter with RS485-LN ==
541 541  
542 542  
543 543  This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to CEM C31 485-T1-MID and send the data for remote minitor. The structure is like below:
544 544  
545 -* Configure Document For RS485-LN:  [[CEM C31 485-T1-MID>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/ELECTRICAL%20CABINET/&file=ELECTRICAL%20CABINET%20READINGS.pdf||_mstmutation="1" style="background-color: rgb(255, 255, 255);"]]
547 +* Configure Document For RS485-LN:  [[CEM C31 485-T1-MID>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/ELECTRICAL%20CABINET/&file=ELECTRICAL%20CABINET%20READINGS.pdf||style="background-color: rgb(255, 255, 255);"]]
546 546  
547 547  
550 +
548 548  == 1.7 Example 7: Schneider Electric PLC M221 with RS485-BL ==
549 549  
550 550  
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0