Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Bei
1 +XWiki.Xiaoling
Content
... ... @@ -61,9 +61,9 @@
61 61  
62 62  
63 63  
64 +
64 64  == **1.3 Example3: Use RS485-LN with energy meters** ==
65 65  
66 -
67 67  === **1.3.1 OverView** ===
68 68  
69 69  
... ... @@ -82,7 +82,7 @@
82 82  
83 83  
84 84  (((
85 -(% style="color:blue" %)**How to connect with Energy Meter:**
85 +**How to connect with Energy Meter:**
86 86  
87 87  
88 88  )))
... ... @@ -112,12 +112,12 @@
112 112  Connection2
113 113  
114 114  
115 +
115 115  [[image:image-20220527092555-7.png]]
116 116  
117 117  Connection3
118 118  
119 119  
120 -
121 121  === **1.3.2 How to use the parameters of the energy meter and MODBUS commands** ===
122 122  
123 123  
... ... @@ -164,7 +164,6 @@
164 164  RS485-LN provides two configuration methods: AT COMMAND and DOWNLINK.
165 165  
166 166  
167 -
168 168  ==== **1.3.3.1 via AT COMMAND** ====
169 169  
170 170  
... ... @@ -220,7 +220,7 @@
220 220  (((
221 221  (% style="color:blue" %)**Example**:
222 222  
223 -(% style="color:red" %)**CMD1:**(%%) Read current data with MODBUS command. address: 0x03 AT+COMMAND1= 01 03 00 03 00 01,1
222 +CMD1: Read current data with MODBUS command. address: 0x03 AT+COMMAND1= 01 03 00 03 00 01,1
224 224  )))
225 225  
226 226  (((
... ... @@ -234,7 +234,7 @@
234 234  )))
235 235  
236 236  (((
237 -(% style="color:red" %)**CMD2: **(%%)Read voltage data with MODBUS command. address: 0x00 AT+COMMAND2= 01 03 00 00 00 01,1
236 +CMD2: Read voltage data with MODBUS command. address: 0x00 AT+COMMAND2= 01 03 00 00 00 01,1
238 238  )))
239 239  
240 240  (((
... ... @@ -248,7 +248,7 @@
248 248  )))
249 249  
250 250  (((
251 -(% style="color:red" %)**CMD3:**(%%) Read total active energy data with MODBUS command. address: 0x0031 AT+COMMAND3= 01 03 00 31 00 02,1
250 +CMD3: Read total active energy data with MODBUS command. address: 0x0031 AT+COMMAND3= 01 03 00 31 00 02,1
252 252  )))
253 253  
254 254  (((
... ... @@ -276,7 +276,6 @@
276 276  AT COMMAND
277 277  
278 278  
279 -
280 280  ==== **1.3.3.2 via LoRaWAN DOWNLINK** ====
281 281  
282 282  
... ... @@ -302,7 +302,7 @@
302 302  )))
303 303  
304 304  (((
305 -(% style="color:red" %)**Note: if user use AT+COMMANDx to add a new command, he also need to send AT+DATACUTx downlink.**
303 +(% style="color:red" %)Note: if user use AT+COMMANDx to add a new command, he also need to send AT+DATACUTx downlink.
306 306  )))
307 307  
308 308  (((
... ... @@ -376,7 +376,6 @@
376 376  DOWNLINK
377 377  
378 378  
379 -
380 380  === **1.3.4 How to configure and output commands for RS485 to USB** ===
381 381  
382 382  (((
... ... @@ -434,7 +434,6 @@
434 434  USB
435 435  
436 436  
437 -
438 438  === **1.3.5 How to configure multiple devices and modify device addresses** ===
439 439  
440 440  
... ... @@ -465,7 +465,7 @@
465 465  
466 466  (((
467 467  (((
468 -We can use (% style="color:blue" %)**AT+CFGDEV**(%%) to set the device address.
464 +We can use **AT+CFGDEV** to set the device address.
469 469  )))
470 470  )))
471 471  
... ... @@ -509,7 +509,7 @@
509 509  [[image:image-20220601142607-4.png]]
510 510  
511 511  
512 -(% style="color:blue" %)**PAYLOAD: 01 08 DF 43 62**
508 +**PAYLOAD:01 08 DF 43 62**
513 513  
514 514  * 08 DF is the valid value of the meter with device address 02.
515 515  * 43 62 is the valid value of the meter with device address 01.