<
From version < 58.1 >
edited by Xiaoling
on 2022/07/14 10:20
To version < 57.17 >
edited by Xiaoling
on 2022/07/14 09:58
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -36,8 +36,6 @@
36 36  * [[Video Demo>>url:https://www.youtube.com/watch?v=TAFZ5eaf-MY&t=6s&ab_channel=XavierFlorensaBerenguer]]
37 37  
38 38  
39 -
40 -
41 41  == **1.2 Example 2: Connect to Pulse Counter** ==
42 42  
43 43  
... ... @@ -62,7 +62,6 @@
62 62  
63 63  
64 64  
65 -
66 66  == **1.3 Example3: Use RS485-LN with energy meters** ==
67 67  
68 68  
... ... @@ -119,7 +119,6 @@
119 119  Connection3
120 120  
121 121  
122 -
123 123  === **1.3.2 How to use the parameters of the energy meter and MODBUS commands** ===
124 124  
125 125  
... ... @@ -166,7 +166,6 @@
166 166  RS485-LN provides two configuration methods: AT COMMAND and DOWNLINK.
167 167  
168 168  
169 -
170 170  ==== **1.3.3.1 via AT COMMAND** ====
171 171  
172 172  
... ... @@ -222,7 +222,7 @@
222 222  (((
223 223  (% style="color:blue" %)**Example**:
224 224  
225 -(% style="color:red" %)**CMD1:**(%%) Read current data with MODBUS command. address: 0x03 AT+COMMAND1= 01 03 00 03 00 01,1
220 +**CMD1:** Read current data with MODBUS command. address: 0x03 AT+COMMAND1= 01 03 00 03 00 01,1
226 226  )))
227 227  
228 228  (((
... ... @@ -236,7 +236,7 @@
236 236  )))
237 237  
238 238  (((
239 -(% style="color:red" %)**CMD2: **(%%)Read voltage data with MODBUS command. address: 0x00 AT+COMMAND2= 01 03 00 00 00 01,1
234 +**CMD2: **Read voltage data with MODBUS command. address: 0x00 AT+COMMAND2= 01 03 00 00 00 01,1
240 240  )))
241 241  
242 242  (((
... ... @@ -250,7 +250,7 @@
250 250  )))
251 251  
252 252  (((
253 -(% style="color:red" %)**CMD3:**(%%) Read total active energy data with MODBUS command. address: 0x0031 AT+COMMAND3= 01 03 00 31 00 02,1
248 +**CMD3:** Read total active energy data with MODBUS command. address: 0x0031 AT+COMMAND3= 01 03 00 31 00 02,1
254 254  )))
255 255  
256 256  (((
... ... @@ -278,7 +278,6 @@
278 278  AT COMMAND
279 279  
280 280  
281 -
282 282  ==== **1.3.3.2 via LoRaWAN DOWNLINK** ====
283 283  
284 284  
... ... @@ -304,7 +304,7 @@
304 304  )))
305 305  
306 306  (((
307 -(% style="color:red" %)**Note: if user use AT+COMMANDx to add a new command, he also need to send AT+DATACUTx downlink.**
301 +(% style="color:red" %)Note: if user use AT+COMMANDx to add a new command, he also need to send AT+DATACUTx downlink.
308 308  )))
309 309  
310 310  (((
... ... @@ -378,7 +378,6 @@
378 378  DOWNLINK
379 379  
380 380  
381 -
382 382  === **1.3.4 How to configure and output commands for RS485 to USB** ===
383 383  
384 384  (((
... ... @@ -436,7 +436,6 @@
436 436  USB
437 437  
438 438  
439 -
440 440  === **1.3.5 How to configure multiple devices and modify device addresses** ===
441 441  
442 442  
... ... @@ -467,7 +467,7 @@
467 467  
468 468  (((
469 469  (((
470 -We can use (% style="color:blue" %)**AT+CFGDEV**(%%) to set the device address.
462 +We can use **AT+CFGDEV** to set the device address.
471 471  )))
472 472  )))
473 473  
... ... @@ -511,14 +511,12 @@
511 511  [[image:image-20220601142607-4.png]]
512 512  
513 513  
514 -(% style="color:blue" %)**PAYLOAD: 01 08 DF 43 62**
506 +**PAYLOAD:01 08 DF 43 62**
515 515  
516 516  * 08 DF is the valid value of the meter with device address 02.
517 517  * 43 62 is the valid value of the meter with device address 01.
518 518  
519 519  
520 -
521 -
522 522  == 1.4 Example 4: Circuit Breaker Remote Open Close ==
523 523  
524 524  
... ... @@ -534,8 +534,6 @@
534 534  * Configure Documen:  [[Circuit Breaker Remote Open Close>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Circuit_Breaker_Remote_Open_Close/]]
535 535  
536 536  
537 -
538 -
539 539  == 1.5 Example 5: SEM Three Energy Meter with RS485-BL or RS485-LN ==
540 540  
541 541  
... ... @@ -545,8 +545,6 @@
545 545  * Configure Document for RS485-LN:  [[Connect to SEM Three>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/SEM_Three_Energy_Meter/&file=SEM%20three%20and%20Dragino%20RS485-LN%20v1.pdf]]
546 546  
547 547  
548 -
549 -
550 550  == 1.6 Example 6: CEM C31 485-T1-MID Energy Meter with RS485-LN ==
551 551  
552 552  
... ... @@ -555,8 +555,6 @@
555 555  * Configure Document For RS485-LN:  [[CEM C31 485-T1-MID>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/ELECTRICAL%20CABINET/&file=ELECTRICAL%20CABINET%20READINGS.pdf||style="background-color: rgb(255, 255, 255);"]]
556 556  
557 557  
558 -
559 -
560 560  == 1.7 Example 7: Schneider Electric PLC M221 with RS485-BL ==
561 561  
562 562  
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0