Last modified by Karry Zhuang on 2024/07/11 11:58
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 5 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,6 +1,5 @@ 1 1 (% class="wikigeneratedid" %) 2 -* 3 -** Table of** **Contents: 2 + **Contents:** 4 4 5 5 {{toc/}} 6 6 ... ... @@ -11,13 +11,11 @@ 11 11 12 12 = **1. Introduction** = 13 13 14 - 15 15 This article provide the examples for RS485-LN to connect to different type of RS485 sensors. 16 16 17 17 18 18 == **1.1 Example 1: Connect to Leak relay and VFD** == 19 19 20 - 21 21 This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to Relay and VFD and communicate with Mobile. The structure is like below: 22 22 23 23 [[image:image-20220527091852-1.png]] ... ... @@ -37,12 +37,11 @@ 37 37 * [[Configure Manual>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Relay_VFD/]] : Explanation on how to integrate to Node-red and to the Mobile Phone, and with link to the Github code. 38 38 * [[Video Demo>>url:https://www.youtube.com/watch?v=TAFZ5eaf-MY&t=6s&ab_channel=XavierFlorensaBerenguer]] 39 39 37 + 40 40 == **1.2 Example 2: Connect to Pulse Counter** == 41 41 42 - 43 43 This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to Pulse Counter and communicate with Mobile. This example and example 2 compose the structure for a farm IoT solution. The structure is like below: 44 44 45 - 46 46 [[image:image-20220527092058-3.png]] 47 47 48 48 Connection ... ... @@ -54,16 +54,17 @@ 54 54 Connection 55 55 56 56 57 -* Configure Document:[[Pickdata MIO40 water pulse counter to LoRa with Dragino RS485-LN>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Pulse-Counter/]]53 +* [[Pickdata MIO40 water pulse counter to LoRa with Dragino RS485-LN>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Pulse-Counter/]] : Configure Document 58 58 * [[Dragino Solution in Farm>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/&file=Dragino%20on%20Farms.pptx]] 59 59 56 +== == 57 + 60 60 == **1.3 Example3: Use RS485-LN with energy meters** == 61 61 62 62 === **1.3.1 OverView** === 63 63 64 - 65 65 ((( 66 - (% style="color:red" %)**Note**:The specifications of each energy meter are different, please refer to your own energy meter specifications.63 +**Note**:The specifications of each energy meter are different, please refer to your own energy meter specifications. 67 67 ))) 68 68 69 69 ((( ... ... @@ -77,9 +77,7 @@ 77 77 78 78 79 79 ((( 80 -**How to connect with Energy Meter:** 81 - 82 - 77 +How to connect with Energy Meter: 83 83 ))) 84 84 85 85 ((( ... ... @@ -115,13 +115,15 @@ 115 115 116 116 === **1.3.2 How to use the parameters of the energy meter and MODBUS commands** === 117 117 118 - 119 119 If the user needs to read the parameters of the electric energy meter and use the modbus command,please refer to the appendix of the MODBUS communication protocol in the user manual of the energy meter. 120 120 121 121 [[image:image-20220601143257-10.png]] 122 122 123 123 124 -(% style="color:blue" %)**Example:**(%%) AT+COMMAND1=01 03 00 00 00 01 84 0A 118 +(% class="box infomessage" %) 119 +((( 120 +**Example:** AT+COMMAND1=01 03 00 00 00 01 84 0A 121 +))) 125 125 126 126 * The first byte : slave address code (=001~247) 127 127 * The second byte : read register value function code ... ... @@ -130,12 +130,12 @@ 130 130 * 7th and 8th bytes: CRC16 checksum from bytes 1 to 6. 131 131 132 132 ((( 133 - 134 - 135 - 136 136 How to parse the reading of the return command of the parameter: 131 +))) 137 137 138 -(% style="color:blue" %)**Example:**(%%) RETURN1:01 03 02 08 FD 7E 05 133 +(% class="box infomessage" %) 134 +((( 135 +**Example:** RETURN1:01 03 02 08 FD 7E 05 139 139 ))) 140 140 141 141 * The first byte ARD: slave address code (=001~254) ... ... @@ -148,22 +148,17 @@ 148 148 (% class="wikigeneratedid" %) 149 149 ((( 150 150 151 - 152 - 153 - 154 154 ))) 155 155 156 156 === **1.3.3 How to configure RS485-LN and parse output commands** === 157 157 158 - 159 159 RS485-LN provides two configuration methods: AT COMMAND and DOWNLINK. 160 160 161 161 162 -==== **1.3.3.1 via AT COMMAND** ==== 155 +==== **1.3.3.1 via AT COMMAND:** ==== 163 163 157 +First, we can use **AT+CFGDEV** to get the return value, and we can also judge whether the input parameters are correct. 164 164 165 -First, we can use (% style="color:blue" %)**AT+CFGDEV**(%%) to get the return value, and we can also judge whether the input parameters are correct. 166 - 167 167 ((( 168 168 If the configured parameters and commands are incorrect, the return value is not obtained. 169 169 ))) ... ... @@ -175,7 +175,7 @@ 175 175 176 176 (% class="box infomessage" %) 177 177 ((( 178 - **AT+DATACUTx**:This command defines how to handle the return from AT+COMMANDx, max reture length is 40 bytes. AT+DATACUTx=a,b,c170 + AT+DATACUTx : This command defines how to handle the return from AT+COMMANDx, max reture length is 40 bytes. AT+DATACUTx=a,b,c 179 179 ))) 180 180 181 181 a: length for the return of AT+COMMAND ... ... @@ -212,49 +212,49 @@ 212 212 ))) 213 213 214 214 ((( 215 -(% style="color:b lue" %)**Example**:207 +(% style="color:#4f81bd" %)**Example**: 216 216 217 -CMD1: 209 +CMD1:Read current data with MODBUS command. address:0x03 AT+COMMAND1= 01 03 00 03 00 01,1 218 218 ))) 219 219 220 220 ((( 221 -RETURN1: 213 +RETURN1:01 03 02 00 02 39 85 00 00(return data) 222 222 ))) 223 223 224 224 ((( 225 -AT+DATACUT1: 217 +AT+DATACUT1:9,1,4+5+6+7 Take the return value 00 02 39 85 as the valid value of reading current data and used to splice payload. 226 226 227 227 228 228 ))) 229 229 230 230 ((( 231 -CMD2: 223 +CMD2:Read voltage data with MODBUS command. address:0x00 AT+COMMAND2= 01 03 00 00 00 01,1 232 232 ))) 233 233 234 234 ((( 235 -RETURN2: 227 +RETURN2:01 03 02 08 DC BE 1D(return data) 236 236 ))) 237 237 238 238 ((( 239 -AT+DATACUT2: 231 +AT+DATACUT2:7,1,4+5 Take the return value 08 DC as the valid value of reading voltage data and used to splice payload. 240 240 241 241 242 242 ))) 243 243 244 244 ((( 245 -CMD3: 237 +CMD3:Read total active energy data with MODBUS command. address:0x0031 AT+COMMAND3= 01 03 00 31 00 02,1 246 246 ))) 247 247 248 248 ((( 249 -RETURN3: 241 +RETURN3:01 03 04 00 00 00 44 FA 00(return data) 250 250 ))) 251 251 252 252 ((( 253 -AT+DATACUT3: 245 +AT+DATACUT3:9,1,4+5+6+7 Take the return value 00 00 00 44 as the valid value of reading total active energy data and used to splice payload. 254 254 ))) 255 255 256 256 ((( 257 -Payload: 249 +Payload:01 00 02 39 85 08 DC 00 00 00 44 258 258 ))) 259 259 260 260 [[image:image-20220601142936-6.png]] ... ... @@ -266,7 +266,7 @@ 266 266 267 267 268 268 269 -[[image:image-20220 601143642-2.png]]261 +[[image:image-20220527093251-14.png]] 270 270 271 271 AT COMMAND 272 272 ... ... @@ -273,7 +273,6 @@ 273 273 274 274 ==== **1.3.3.2 via LoRaWAN DOWNLINK** ==== 275 275 276 - 277 277 [[image:image-20220527093358-15.png]] 278 278 279 279 ((( ... ... @@ -341,25 +341,25 @@ 341 341 **AF 03 01 06 0A 05 00 04 00 01 00**: Same as AT+COMMAND3=0A 05 00 04 00 01,1 342 342 ))) 343 343 344 -[[image:image-20220 601144149-6.png]]335 +[[image:image-20220527093430-16.png]] 345 345 346 346 DOWNLINK 347 347 348 348 349 349 350 -[[image:image-20220 601143803-3.png]]341 +[[image:image-20220527093508-17.png]] 351 351 352 352 DOWNLINK 353 353 354 354 355 355 356 -[[image:image-20220 601144053-5.png]]347 +[[image:image-20220527093530-18.png]] 357 357 358 358 DOWNLINK 359 359 360 360 361 361 362 -[[image:image-20220601 143921-4.png]]353 +[[image:image-20220527093607-19.png]] 363 363 364 364 DOWNLINK 365 365 ... ... @@ -438,7 +438,6 @@ 438 438 439 439 [[image:image-20220527093950-25.png]] 440 440 441 - 442 442 [[image:image-20220527094028-26.png]] 443 443 444 444 ((( ... ... @@ -514,6 +514,7 @@ 514 514 515 515 * [[Connect to SEM Three>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/SEM_Three_Energy_Meter/&file=SEM%20three%20and%20Dragino%20RS485-LN%20v1.pdf]] : Configure Document for RS485-LN 516 516 507 + 517 517 == 1.6 Example 6:CEM C31 485-T1-MID Energy Meter with RS485-LN == 518 518 519 519 This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to CEM C31 485-T1-MID and send the data for remote minitor. The structure is like below: ... ... @@ -520,6 +520,7 @@ 520 520 521 521 * [[CEM C31 485-T1-MID>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/ELECTRICAL%20CABINET/&file=ELECTRICAL%20CABINET%20READINGS.pdf]] : Configure Document For RS485-LN 522 522 514 + 523 523 == 1.7 Example 7:Schneider Electric PLC M221 with RS485-BL == 524 524 525 525 [[image:image-20220527094556-31.png]]
- image-20220601143642-2.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -41.4 KB - Content
- image-20220601143803-3.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -22.8 KB - Content
- image-20220601143921-4.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -29.2 KB - Content
- image-20220601144053-5.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -17.1 KB - Content
- image-20220601144149-6.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -17.4 KB - Content