<
From version < 57.7 >
edited by Xiaoling
on 2022/07/14 09:20
To version < 53.1 >
edited by Xiaoling
on 2022/06/01 14:36
>
Change comment: Uploaded new attachment "image-20220601143642-2.png", version {1}

Summary

Details

Page properties
Content
... ... @@ -1,5 +1,5 @@
1 1  (% class="wikigeneratedid" %)
2 - ** Table of** **Contents:**
2 + **Contents:**
3 3  
4 4  {{toc/}}
5 5  
... ... @@ -10,13 +10,11 @@
10 10  
11 11  = **1. Introduction** =
12 12  
13 -
14 14  This article provide the examples for RS485-LN to connect to different type of RS485 sensors.
15 15  
16 16  
17 17  == **1.1 Example 1: Connect to Leak relay and VFD** ==
18 18  
19 -
20 20  This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to Relay and VFD and communicate with Mobile. The structure is like below:
21 21  
22 22  [[image:image-20220527091852-1.png]]
... ... @@ -37,14 +37,10 @@
37 37  * [[Video Demo>>url:https://www.youtube.com/watch?v=TAFZ5eaf-MY&t=6s&ab_channel=XavierFlorensaBerenguer]]
38 38  
39 39  
40 -
41 -
42 42  == **1.2 Example 2: Connect to Pulse Counter** ==
43 43  
44 -
45 45  This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to Pulse Counter and communicate with Mobile. This example and example 2 compose the structure for a farm IoT solution. The structure is like below:
46 46  
47 -
48 48  [[image:image-20220527092058-3.png]]
49 49  
50 50  Connection
... ... @@ -56,12 +56,11 @@
56 56  Connection
57 57  
58 58  
59 -* Configure Document: [[Pickdata MIO40 water pulse counter to LoRa with Dragino RS485-LN>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Pulse-Counter/]]
53 +* [[Pickdata MIO40 water pulse counter to LoRa with Dragino RS485-LN>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Pulse-Counter/]] : Configure Document
60 60  * [[Dragino Solution in Farm>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/&file=Dragino%20on%20Farms.pptx]]
61 61  
56 +== ==
62 62  
63 -
64 -
65 65  == **1.3 Example3: Use RS485-LN with energy meters** ==
66 66  
67 67  === **1.3.1 OverView** ===
... ... @@ -265,7 +265,7 @@
265 265  
266 266  
267 267  
268 -[[image:image-20220601143642-2.png]]
261 +[[image:image-20220527093251-14.png]]
269 269  
270 270  AT COMMAND
271 271  
... ... @@ -339,25 +339,25 @@
339 339  **AF 03 01 06 0A 05 00 04 00 01 00**: Same as AT+COMMAND3=0A 05 00 04 00 01,1
340 340  )))
341 341  
342 -[[image:image-20220601144149-6.png]]
335 +[[image:image-20220527093430-16.png]]
343 343  
344 344  DOWNLINK
345 345  
346 346  
347 347  
348 -[[image:image-20220601143803-3.png]]
341 +[[image:image-20220527093508-17.png]]
349 349  
350 350  DOWNLINK
351 351  
352 352  
353 353  
354 -[[image:image-20220601144053-5.png]]
347 +[[image:image-20220527093530-18.png]]
355 355  
356 356  DOWNLINK
357 357  
358 358  
359 359  
360 -[[image:image-20220601143921-4.png]]
353 +[[image:image-20220527093607-19.png]]
361 361  
362 362  DOWNLINK
363 363  
... ... @@ -436,7 +436,6 @@
436 436  
437 437  [[image:image-20220527093950-25.png]]
438 438  
439 -
440 440  [[image:image-20220527094028-26.png]]
441 441  
442 442  (((
... ... @@ -494,7 +494,6 @@
494 494  * 08 DF is the valid value of the meter with device address 02.
495 495  * 43 62 is the valid value of the meter with device address 01.
496 496  
497 -
498 498  == 1.4 Example 4: Circuit Breaker Remote Open Close ==
499 499  
500 500  This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to SCHNEIDER SMART and Monitor and control your cabinet remotely with no wires and with Dragino RS485-LN LoRaWAN technology. The structure is like below:
... ... @@ -513,6 +513,7 @@
513 513  
514 514  * [[Connect to SEM Three>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/SEM_Three_Energy_Meter/&file=SEM%20three%20and%20Dragino%20RS485-LN%20v1.pdf]] : Configure Document for RS485-LN
515 515  
507 +
516 516  == 1.6 Example 6:CEM C31 485-T1-MID Energy Meter with RS485-LN ==
517 517  
518 518  This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to CEM C31 485-T1-MID and send the data for remote minitor. The structure is like below:
... ... @@ -519,6 +519,7 @@
519 519  
520 520  * [[CEM C31 485-T1-MID>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/ELECTRICAL%20CABINET/&file=ELECTRICAL%20CABINET%20READINGS.pdf]] : Configure Document For RS485-LN
521 521  
514 +
522 522  == 1.7 Example 7:Schneider Electric PLC M221 with RS485-BL ==
523 523  
524 524  [[image:image-20220527094556-31.png]]
image-20220601143803-3.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -22.8 KB
Content
image-20220601143921-4.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -29.2 KB
Content
image-20220601144053-5.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -17.1 KB
Content
image-20220601144149-6.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -17.4 KB
Content
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0