Last modified by Karry Zhuang on 2024/07/11 11:58
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 5 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,5 +1,5 @@ 1 1 (% class="wikigeneratedid" %) 2 - **Table of****Contents:**2 + **Contents:** 3 3 4 4 {{toc/}} 5 5 ... ... @@ -10,13 +10,11 @@ 10 10 11 11 = **1. Introduction** = 12 12 13 - 14 14 This article provide the examples for RS485-LN to connect to different type of RS485 sensors. 15 15 16 16 17 17 == **1.1 Example 1: Connect to Leak relay and VFD** == 18 18 19 - 20 20 This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to Relay and VFD and communicate with Mobile. The structure is like below: 21 21 22 22 [[image:image-20220527091852-1.png]] ... ... @@ -37,14 +37,10 @@ 37 37 * [[Video Demo>>url:https://www.youtube.com/watch?v=TAFZ5eaf-MY&t=6s&ab_channel=XavierFlorensaBerenguer]] 38 38 39 39 40 - 41 - 42 42 == **1.2 Example 2: Connect to Pulse Counter** == 43 43 44 - 45 45 This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to Pulse Counter and communicate with Mobile. This example and example 2 compose the structure for a farm IoT solution. The structure is like below: 46 46 47 - 48 48 [[image:image-20220527092058-3.png]] 49 49 50 50 Connection ... ... @@ -56,12 +56,11 @@ 56 56 Connection 57 57 58 58 59 -* Configure Document:[[Pickdata MIO40 water pulse counter to LoRa with Dragino RS485-LN>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Pulse-Counter/]]53 +* [[Pickdata MIO40 water pulse counter to LoRa with Dragino RS485-LN>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Pulse-Counter/]] : Configure Document 60 60 * [[Dragino Solution in Farm>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/&file=Dragino%20on%20Farms.pptx]] 61 61 56 +== == 62 62 63 - 64 - 65 65 == **1.3 Example3: Use RS485-LN with energy meters** == 66 66 67 67 === **1.3.1 OverView** === ... ... @@ -265,7 +265,7 @@ 265 265 266 266 267 267 268 -[[image:image-20220 601143642-2.png]]261 +[[image:image-20220527093251-14.png]] 269 269 270 270 AT COMMAND 271 271 ... ... @@ -339,25 +339,25 @@ 339 339 **AF 03 01 06 0A 05 00 04 00 01 00**: Same as AT+COMMAND3=0A 05 00 04 00 01,1 340 340 ))) 341 341 342 -[[image:image-20220 601144149-6.png]]335 +[[image:image-20220527093430-16.png]] 343 343 344 344 DOWNLINK 345 345 346 346 347 347 348 -[[image:image-20220 601143803-3.png]]341 +[[image:image-20220527093508-17.png]] 349 349 350 350 DOWNLINK 351 351 352 352 353 353 354 -[[image:image-20220 601144053-5.png]]347 +[[image:image-20220527093530-18.png]] 355 355 356 356 DOWNLINK 357 357 358 358 359 359 360 -[[image:image-20220601 143921-4.png]]353 +[[image:image-20220527093607-19.png]] 361 361 362 362 DOWNLINK 363 363 ... ... @@ -436,7 +436,6 @@ 436 436 437 437 [[image:image-20220527093950-25.png]] 438 438 439 - 440 440 [[image:image-20220527094028-26.png]] 441 441 442 442 ((( ... ... @@ -494,7 +494,6 @@ 494 494 * 08 DF is the valid value of the meter with device address 02. 495 495 * 43 62 is the valid value of the meter with device address 01. 496 496 497 - 498 498 == 1.4 Example 4: Circuit Breaker Remote Open Close == 499 499 500 500 This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to SCHNEIDER SMART and Monitor and control your cabinet remotely with no wires and with Dragino RS485-LN LoRaWAN technology. The structure is like below: ... ... @@ -513,6 +513,7 @@ 513 513 514 514 * [[Connect to SEM Three>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/SEM_Three_Energy_Meter/&file=SEM%20three%20and%20Dragino%20RS485-LN%20v1.pdf]] : Configure Document for RS485-LN 515 515 507 + 516 516 == 1.6 Example 6:CEM C31 485-T1-MID Energy Meter with RS485-LN == 517 517 518 518 This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to CEM C31 485-T1-MID and send the data for remote minitor. The structure is like below: ... ... @@ -519,6 +519,7 @@ 519 519 520 520 * [[CEM C31 485-T1-MID>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/ELECTRICAL%20CABINET/&file=ELECTRICAL%20CABINET%20READINGS.pdf]] : Configure Document For RS485-LN 521 521 514 + 522 522 == 1.7 Example 7:Schneider Electric PLC M221 with RS485-BL == 523 523 524 524 [[image:image-20220527094556-31.png]]
- image-20220601143642-2.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -41.4 KB - Content
- image-20220601143803-3.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -22.8 KB - Content
- image-20220601143921-4.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -29.2 KB - Content
- image-20220601144053-5.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -17.1 KB - Content
- image-20220601144149-6.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -17.4 KB - Content