<
From version < 57.24 >
edited by Xiaoling
on 2022/07/14 10:13
To version < 60.2 >
edited by Xiaoling
on 2022/07/22 17:43
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -31,12 +31,13 @@
31 31  
32 32  (% style="color:blue" %)**Related documents:**
33 33  
34 -* System Structure:  [[Solar Pump with Dragino>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Relay_VFD/||style="background-color: rgb(255, 255, 255);"]]
35 -* Explanation on how to integrate to Node-red and to the Mobile Phone, and with link to the Github code:  [[Configure Manual>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Relay_VFD/||style="background-color: rgb(255, 255, 255);"]]
34 +* System Structure:  [[Solar Pump with Dragino>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Relay_VFD/||_mstmutation="1" style="background-color: rgb(255, 255, 255);"]]
35 +* Explanation on how to integrate to Node-red and to the Mobile Phone, and with link to the Github code:  [[Configure Manual>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Relay_VFD/||_mstmutation="1" style="background-color: rgb(255, 255, 255);"]]
36 36  * [[Video Demo>>url:https://www.youtube.com/watch?v=TAFZ5eaf-MY&t=6s&ab_channel=XavierFlorensaBerenguer]]
37 37  
38 38  
39 39  
40 +
40 40  == **1.2 Example 2: Connect to Pulse Counter** ==
41 41  
42 42  
... ... @@ -56,10 +56,12 @@
56 56  
57 57  (% style="color:blue" %)**Related documents:**
58 58  
59 -* Configure Document:  [[Pickdata MIO40 water pulse counter to LoRa with Dragino RS485-LN>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Pulse-Counter/]]
60 +* Configure Document:  [[Pickdata MIO40 water pulse counter to LoRa with Dragino RS485-LN>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Pulse-Counter/||_mstmutation="1"]]
60 60  * [[Dragino Solution in Farm>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/&file=Dragino%20on%20Farms.pptx]]
61 61  
62 62  
64 +
65 +
63 63  == **1.3 Example3: Use RS485-LN with energy meters** ==
64 64  
65 65  
... ... @@ -104,6 +104,8 @@
104 104  
105 105  (((
106 106  Once there is power, the RS485-LN will be on.
110 +
111 +
107 107  )))
108 108  
109 109  [[image:image-20220527092514-6.png]]
... ... @@ -111,6 +111,7 @@
111 111  Connection2
112 112  
113 113  
119 +
114 114  [[image:image-20220527092555-7.png]]
115 115  
116 116  Connection3
... ... @@ -180,7 +180,7 @@
180 180  
181 181  (% class="box infomessage" %)
182 182  (((
183 - **AT+DATACUTx **:  This command defines how to handle the return from AT+COMMANDx, max reture length is 40 bytes. AT+DATACUTx=a,b,c
189 + (% _mstmutation="1" %)**AT+DATACUTx **(%%):  This command defines how to handle the return from AT+COMMANDx, max reture length is 40 bytes. AT+DATACUTx=a,b,c
184 184  )))
185 185  
186 186  a:  length for the return of AT+COMMAND
... ... @@ -214,6 +214,8 @@
214 214  
215 215  (((
216 216  
223 +
224 +
217 217  )))
218 218  
219 219  (((
... ... @@ -267,6 +267,7 @@
267 267  AT COMMAND
268 268  
269 269  
278 +
270 270  (% style="color:#4f81bd" %)**01 is device address,00 02 is the current, 08 DC is the voltage,00 00 00 44 is the total active energy.**
271 271  
272 272  
... ... @@ -301,7 +301,9 @@
301 301  )))
302 302  
303 303  (((
304 -(% style="color:red" %)Note: if user use AT+COMMANDx to add a new command, he also need to send AT+DATACUTx downlink.
313 +(% style="color:red" %)**Note: if user use AT+COMMANDx to add a new command, he also need to send AT+DATACUTx downlink.**
314 +
315 +
305 305  )))
306 306  
307 307  (((
... ... @@ -378,6 +378,7 @@
378 378  
379 379  === **1.3.4 How to configure and output commands for RS485 to USB** ===
380 380  
392 +
381 381  (((
382 382  This step is not necessary, it is just to show how to use a normal RS485 to USB adapter to connect to the meter to check the input and output. This can be used to test the connection and RS485 command of the meter without RS485-LN.
383 383  )))
... ... @@ -464,7 +464,7 @@
464 464  
465 465  (((
466 466  (((
467 -We can use **AT+CFGDEV** to set the device address.
479 +We can use (% style="color:blue" %)**AT+CFGDEV**(%%) to set the device address.
468 468  )))
469 469  )))
470 470  
... ... @@ -513,9 +513,6 @@
513 513  * 08 DF is the valid value of the meter with device address 02.
514 514  * 43 62 is the valid value of the meter with device address 01.
515 515  
516 -
517 -
518 -
519 519  == 1.4 Example 4: Circuit Breaker Remote Open Close ==
520 520  
521 521  
... ... @@ -528,32 +528,23 @@
528 528  Connection
529 529  
530 530  
531 -* Configure Documen:  [[Circuit Breaker Remote Open Close>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Circuit_Breaker_Remote_Open_Close/]]
540 +* Configure Documen:  [[Circuit Breaker Remote Open Close>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Circuit_Breaker_Remote_Open_Close/||_mstmutation="1"]]
532 532  
533 -
534 -
535 -
536 536  == 1.5 Example 5: SEM Three Energy Meter with RS485-BL or RS485-LN ==
537 537  
538 538  
539 539  This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-BL to connect to SEM Three Energy Meter and send the data to mobile phone for remote minitor. The structure is like below:
540 540  
541 -* Configure Document For RS485-BL:  [[Connect to SEM Three>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/RS485-BL/Application_Note/&file=Dragino%20RS485BL%20and%20pickdata%20SEM%20Three%20v1.pdf||style="background-color: rgb(255, 255, 255);"]]
542 -* Configure Document for RS485-LN:  [[Connect to SEM Three>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/SEM_Three_Energy_Meter/&file=SEM%20three%20and%20Dragino%20RS485-LN%20v1.pdf]]
547 +* Configure Document For RS485-BL:  [[Connect to SEM Three>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/RS485-BL/Application_Note/&file=Dragino%20RS485BL%20and%20pickdata%20SEM%20Three%20v1.pdf||_mstmutation="1" style="background-color: rgb(255, 255, 255);"]]
548 +* Configure Document for RS485-LN:  [[Connect to SEM Three>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/SEM_Three_Energy_Meter/&file=SEM%20three%20and%20Dragino%20RS485-LN%20v1.pdf||_mstmutation="1"]]
543 543  
544 -
545 -
546 -
547 547  == 1.6 Example 6: CEM C31 485-T1-MID Energy Meter with RS485-LN ==
548 548  
549 549  
550 550  This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to CEM C31 485-T1-MID and send the data for remote minitor. The structure is like below:
551 551  
552 -* Configure Document For RS485-LN:  [[CEM C31 485-T1-MID>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/ELECTRICAL%20CABINET/&file=ELECTRICAL%20CABINET%20READINGS.pdf||style="background-color: rgb(255, 255, 255);"]]
555 +* Configure Document For RS485-LN:  [[CEM C31 485-T1-MID>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/ELECTRICAL%20CABINET/&file=ELECTRICAL%20CABINET%20READINGS.pdf||_mstmutation="1" style="background-color: rgb(255, 255, 255);"]]
553 553  
554 -
555 -
556 -
557 557  == 1.7 Example 7: Schneider Electric PLC M221 with RS485-BL ==
558 558  
559 559  
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0