... ... @@ -60,6 +60,8 @@
60 60  * [[Dragino Solution in Farm>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/&file=Dragino%20on%20Farms.pptx]]
61 61  
62 62  
63 +
64 +
63 63  == **1.3 Example3: Use RS485-LN with energy meters** ==
64 64  
65 65  
... ... @@ -111,12 +111,12 @@
111 111  Connection2
112 112  
113 113  
116 +
114 114  [[image:image-20220527092555-7.png]]
115 115  
116 116  Connection3
117 117  
118 118  
119 -
120 120  === **1.3.2 How to use the parameters of the energy meter and MODBUS commands** ===
121 121  
122 122  
... ... @@ -163,7 +163,6 @@
163 163  RS485-LN provides two configuration methods: AT COMMAND and DOWNLINK.
164 164  
165 165  
166 -
167 167  ==== **1.3.3.1 via AT COMMAND** ====
168 168  
169 169  
... ... @@ -219,7 +219,7 @@
219 219  (((
220 220  (% style="color:blue" %)**Example**:
221 221  
222 -(% style="color:red" %)**CMD1:**(%%) Read current data with MODBUS command. address: 0x03 AT+COMMAND1= 01 03 00 03 00 01,1
223 +CMD1: Read current data with MODBUS command. address: 0x03 AT+COMMAND1= 01 03 00 03 00 01,1
223 223  )))
224 224  
225 225  (((
... ... @@ -233,7 +233,7 @@
233 233  )))
234 234  
235 235  (((
236 -(% style="color:red" %)**CMD2: **(%%)Read voltage data with MODBUS command. address: 0x00 AT+COMMAND2= 01 03 00 00 00 01,1
237 +CMD2: Read voltage data with MODBUS command. address: 0x00 AT+COMMAND2= 01 03 00 00 00 01,1
237 237  )))
238 238  
239 239  (((
... ... @@ -247,7 +247,7 @@
247 247  )))
248 248  
249 249  (((
250 -(% style="color:red" %)**CMD3:**(%%) Read total active energy data with MODBUS command. address: 0x0031 AT+COMMAND3= 01 03 00 31 00 02,1
251 +CMD3: Read total active energy data with MODBUS command. address: 0x0031 AT+COMMAND3= 01 03 00 31 00 02,1
251 251  )))
252 252  
253 253  (((
... ... @@ -275,7 +275,6 @@
275 275  AT COMMAND
276 276  
277 277  
278 -
279 279  ==== **1.3.3.2 via LoRaWAN DOWNLINK** ====
280 280  
281 281  
... ... @@ -375,7 +375,6 @@
375 375  DOWNLINK
376 376  
377 377  
378 -
379 379  === **1.3.4 How to configure and output commands for RS485 to USB** ===
380 380  
381 381  (((
... ... @@ -433,7 +433,6 @@
433 433  USB
434 434  
435 435  
436 -
437 437  === **1.3.5 How to configure multiple devices and modify device addresses** ===
438 438  
439 439  
... ... @@ -508,7 +508,7 @@
508 508  [[image:image-20220601142607-4.png]]
509 509  
510 510  
511 -(% style="color:blue" %)**PAYLOAD: 01 08 DF 43 62**
509 +**PAYLOAD:01 08 DF 43 62**
512 512  
513 513  * 08 DF is the valid value of the meter with device address 02.
514 514  * 43 62 is the valid value of the meter with device address 01.
... ... @@ -515,7 +515,6 @@
515 515  
516 516  
517 517  
518 -
519 519  == 1.4 Example 4: Circuit Breaker Remote Open Close ==
520 520  
521 521  
... ... @@ -532,7 +532,6 @@
532 532  
533 533  
534 534  
535 -
536 536  == 1.5 Example 5: SEM Three Energy Meter with RS485-BL or RS485-LN ==
537 537  
538 538  
... ... @@ -543,7 +543,6 @@
543 543  
544 544  
545 545  
546 -
547 547  == 1.6 Example 6: CEM C31 485-T1-MID Energy Meter with RS485-LN ==
548 548  
549 549  
... ... @@ -553,7 +553,6 @@
553 553  
554 554  
555 555  
556 -
557 557  == 1.7 Example 7: Schneider Electric PLC M221 with RS485-BL ==
558 558  
559 559  