... ... @@ -37,7 +37,6 @@
37 37  
38 38  
39 39  
40 -
41 41  == **1.2 Example 2: Connect to Pulse Counter** ==
42 42  
43 43  
... ... @@ -61,7 +61,6 @@
61 61  * [[Dragino Solution in Farm>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/&file=Dragino%20on%20Farms.pptx]]
62 62  
63 63  
64 -
65 65  == **1.3 Example3: Use RS485-LN with energy meters** ==
66 66  
67 67  
... ... @@ -118,6 +118,7 @@
118 118  Connection3
119 119  
120 120  
119 +
121 121  === **1.3.2 How to use the parameters of the energy meter and MODBUS commands** ===
122 122  
123 123  
... ... @@ -164,6 +164,7 @@
164 164  RS485-LN provides two configuration methods: AT COMMAND and DOWNLINK.
165 165  
166 166  
166 +
167 167  ==== **1.3.3.1 via AT COMMAND** ====
168 168  
169 169  
... ... @@ -275,6 +275,7 @@
275 275  AT COMMAND
276 276  
277 277  
278 +
278 278  ==== **1.3.3.2 via LoRaWAN DOWNLINK** ====
279 279  
280 280  
... ... @@ -374,6 +374,7 @@
374 374  DOWNLINK
375 375  
376 376  
378 +
377 377  === **1.3.4 How to configure and output commands for RS485 to USB** ===
378 378  
379 379  (((
... ... @@ -431,6 +431,7 @@
431 431  USB
432 432  
433 433  
436 +
434 434  === **1.3.5 How to configure multiple devices and modify device addresses** ===
435 435  
436 436  
... ... @@ -505,11 +505,14 @@
505 505  [[image:image-20220601142607-4.png]]
506 506  
507 507  
508 -**PAYLOAD:01 08 DF 43 62**
511 +(% style="color:blue" %)**PAYLOAD: 01 08 DF 43 62**
509 509  
510 510  * 08 DF is the valid value of the meter with device address 02.
511 511  * 43 62 is the valid value of the meter with device address 01.
512 512  
516 +
517 +
518 +
513 513  == 1.4 Example 4: Circuit Breaker Remote Open Close ==
514 514  
515 515  
... ... @@ -524,6 +524,9 @@
524 524  
525 525  * Configure Documen:  [[Circuit Breaker Remote Open Close>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Circuit_Breaker_Remote_Open_Close/]]
526 526  
533 +
534 +
535 +
527 527  == 1.5 Example 5: SEM Three Energy Meter with RS485-BL or RS485-LN ==
528 528  
529 529  
... ... @@ -532,6 +532,9 @@
532 532  * Configure Document For RS485-BL:  [[Connect to SEM Three>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/RS485-BL/Application_Note/&file=Dragino%20RS485BL%20and%20pickdata%20SEM%20Three%20v1.pdf||style="background-color: rgb(255, 255, 255);"]]
533 533  * Configure Document for RS485-LN:  [[Connect to SEM Three>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/SEM_Three_Energy_Meter/&file=SEM%20three%20and%20Dragino%20RS485-LN%20v1.pdf]]
534 534  
544 +
545 +
546 +
535 535  == 1.6 Example 6: CEM C31 485-T1-MID Energy Meter with RS485-LN ==
536 536  
537 537  