<
From version < 57.20 >
edited by Xiaoling
on 2022/07/14 10:10
To version < 57.15 >
edited by Xiaoling
on 2022/07/14 09:54
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -37,7 +37,6 @@
37 37  
38 38  
39 39  
40 -
41 41  == **1.2 Example 2: Connect to Pulse Counter** ==
42 42  
43 43  
... ... @@ -62,9 +62,9 @@
62 62  
63 63  
64 64  
64 +
65 65  == **1.3 Example3: Use RS485-LN with energy meters** ==
66 66  
67 -
68 68  === **1.3.1 OverView** ===
69 69  
70 70  
... ... @@ -83,7 +83,7 @@
83 83  
84 84  
85 85  (((
86 -(% style="color:blue" %)**How to connect with Energy Meter:**
85 +**How to connect with Energy Meter:**
87 87  
88 88  
89 89  )))
... ... @@ -113,6 +113,7 @@
113 113  Connection2
114 114  
115 115  
115 +
116 116  [[image:image-20220527092555-7.png]]
117 117  
118 118  Connection3
... ... @@ -219,7 +219,7 @@
219 219  (((
220 220  (% style="color:blue" %)**Example**:
221 221  
222 -(% style="color:red" %)**CMD1:**(%%) Read current data with MODBUS command. address: 0x03 AT+COMMAND1= 01 03 00 03 00 01,1
222 +CMD1: Read current data with MODBUS command. address: 0x03 AT+COMMAND1= 01 03 00 03 00 01,1
223 223  )))
224 224  
225 225  (((
... ... @@ -233,7 +233,7 @@
233 233  )))
234 234  
235 235  (((
236 -(% style="color:red" %)**CMD2: **(%%)Read voltage data with MODBUS command. address: 0x00 AT+COMMAND2= 01 03 00 00 00 01,1
236 +CMD2: Read voltage data with MODBUS command. address: 0x00 AT+COMMAND2= 01 03 00 00 00 01,1
237 237  )))
238 238  
239 239  (((
... ... @@ -247,7 +247,7 @@
247 247  )))
248 248  
249 249  (((
250 -(% style="color:red" %)**CMD3:**(%%) Read total active energy data with MODBUS command. address: 0x0031 AT+COMMAND3= 01 03 00 31 00 02,1
250 +CMD3: Read total active energy data with MODBUS command. address: 0x0031 AT+COMMAND3= 01 03 00 31 00 02,1
251 251  )))
252 252  
253 253  (((
... ... @@ -510,6 +510,8 @@
510 510  * 08 DF is the valid value of the meter with device address 02.
511 511  * 43 62 is the valid value of the meter with device address 01.
512 512  
513 +
514 +
513 513  == 1.4 Example 4: Circuit Breaker Remote Open Close ==
514 514  
515 515  
... ... @@ -524,6 +524,8 @@
524 524  
525 525  * Configure Documen:  [[Circuit Breaker Remote Open Close>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Circuit_Breaker_Remote_Open_Close/]]
526 526  
529 +
530 +
527 527  == 1.5 Example 5: SEM Three Energy Meter with RS485-BL or RS485-LN ==
528 528  
529 529  
... ... @@ -532,6 +532,8 @@
532 532  * Configure Document For RS485-BL:  [[Connect to SEM Three>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/RS485-BL/Application_Note/&file=Dragino%20RS485BL%20and%20pickdata%20SEM%20Three%20v1.pdf||style="background-color: rgb(255, 255, 255);"]]
533 533  * Configure Document for RS485-LN:  [[Connect to SEM Three>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/SEM_Three_Energy_Meter/&file=SEM%20three%20and%20Dragino%20RS485-LN%20v1.pdf]]
534 534  
539 +
540 +
535 535  == 1.6 Example 6: CEM C31 485-T1-MID Energy Meter with RS485-LN ==
536 536  
537 537  
... ... @@ -539,6 +539,8 @@
539 539  
540 540  * Configure Document For RS485-LN:  [[CEM C31 485-T1-MID>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/ELECTRICAL%20CABINET/&file=ELECTRICAL%20CABINET%20READINGS.pdf||style="background-color: rgb(255, 255, 255);"]]
541 541  
548 +
549 +
542 542  == 1.7 Example 7: Schneider Electric PLC M221 with RS485-BL ==
543 543  
544 544  
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0