Last modified by Karry Zhuang on 2024/07/11 11:58
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -29,15 +29,12 @@ 29 29 Connection 30 30 31 31 32 - (% style="color:blue" %)**Related documents:**32 +Related documents: 33 33 34 -* System Structure:[[Solar Pump with Dragino>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Relay_VFD/||style="background-color: rgb(255, 255, 255);"]]35 -* Explanation on how to integrate to Node-red and to the Mobile Phone, and with link to the Github code:[[Configure Manual>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Relay_VFD/||style="background-color:rgb(255,255,255);"]]34 +* [[Solar Pump with Dragino>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Relay_VFD/]] : System Structure 35 +* [[Configure Manual>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Relay_VFD/]] : Explanation on how to integrate to Node-red and to the Mobile Phone, and with link to the Github code. 36 36 * [[Video Demo>>url:https://www.youtube.com/watch?v=TAFZ5eaf-MY&t=6s&ab_channel=XavierFlorensaBerenguer]] 37 37 38 - 39 - 40 - 41 41 == **1.2 Example 2: Connect to Pulse Counter** == 42 42 43 43 ... ... @@ -55,16 +55,11 @@ 55 55 Connection 56 56 57 57 58 -(% style="color:blue" %)**Related documents:** 59 - 60 -* Configure Document: [[Pickdata MIO40 water pulse counter to LoRa with Dragino RS485-LN>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Pulse-Counter/]] 55 +* Configure Document: [[Pickdata MIO40 water pulse counter to LoRa with Dragino RS485-LN>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Pulse-Counter/]] 61 61 * [[Dragino Solution in Farm>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/&file=Dragino%20on%20Farms.pptx]] 62 62 63 - 64 - 65 65 == **1.3 Example3: Use RS485-LN with energy meters** == 66 66 67 - 68 68 === **1.3.1 OverView** === 69 69 70 70 ... ... @@ -83,7 +83,7 @@ 83 83 84 84 85 85 ((( 86 - (% style="color:blue" %)**How to connect with Energy Meter:**78 +**How to connect with Energy Meter:** 87 87 88 88 89 89 ))) ... ... @@ -113,6 +113,7 @@ 113 113 Connection2 114 114 115 115 108 + 116 116 [[image:image-20220527092555-7.png]] 117 117 118 118 Connection3 ... ... @@ -219,7 +219,7 @@ 219 219 ((( 220 220 (% style="color:blue" %)**Example**: 221 221 222 - (% style="color:red" %)**CMD1:**(%%)Read current data with MODBUS command. address: 0x03 AT+COMMAND1= 01 03 00 03 00 01,1215 +CMD1: Read current data with MODBUS command. address: 0x03 AT+COMMAND1= 01 03 00 03 00 01,1 223 223 ))) 224 224 225 225 ((( ... ... @@ -233,7 +233,7 @@ 233 233 ))) 234 234 235 235 ((( 236 - (% style="color:red" %)**CMD2:**(%%)Read voltage data with MODBUS command. address: 0x00 AT+COMMAND2= 01 03 00 00 00 01,1229 +CMD2: Read voltage data with MODBUS command. address: 0x00 AT+COMMAND2= 01 03 00 00 00 01,1 237 237 ))) 238 238 239 239 ((( ... ... @@ -247,7 +247,7 @@ 247 247 ))) 248 248 249 249 ((( 250 - (% style="color:red" %)**CMD3:**(%%)Read total active energy data with MODBUS command. address: 0x0031 AT+COMMAND3= 01 03 00 31 00 02,1243 +CMD3: Read total active energy data with MODBUS command. address: 0x0031 AT+COMMAND3= 01 03 00 31 00 02,1 251 251 ))) 252 252 253 253 ((( ... ... @@ -510,6 +510,9 @@ 510 510 * 08 DF is the valid value of the meter with device address 02. 511 511 * 43 62 is the valid value of the meter with device address 01. 512 512 506 + 507 + 508 + 513 513 == 1.4 Example 4: Circuit Breaker Remote Open Close == 514 514 515 515 ... ... @@ -524,6 +524,9 @@ 524 524 525 525 * Configure Documen: [[Circuit Breaker Remote Open Close>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Circuit_Breaker_Remote_Open_Close/]] 526 526 523 + 524 + 525 + 527 527 == 1.5 Example 5: SEM Three Energy Meter with RS485-BL or RS485-LN == 528 528 529 529 ... ... @@ -532,6 +532,9 @@ 532 532 * Configure Document For RS485-BL: [[Connect to SEM Three>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/RS485-BL/Application_Note/&file=Dragino%20RS485BL%20and%20pickdata%20SEM%20Three%20v1.pdf||style="background-color: rgb(255, 255, 255);"]] 533 533 * Configure Document for RS485-LN: [[Connect to SEM Three>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/SEM_Three_Energy_Meter/&file=SEM%20three%20and%20Dragino%20RS485-LN%20v1.pdf]] 534 534 534 + 535 + 536 + 535 535 == 1.6 Example 6: CEM C31 485-T1-MID Energy Meter with RS485-LN == 536 536 537 537 ... ... @@ -539,6 +539,9 @@ 539 539 540 540 * Configure Document For RS485-LN: [[CEM C31 485-T1-MID>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/ELECTRICAL%20CABINET/&file=ELECTRICAL%20CABINET%20READINGS.pdf||style="background-color: rgb(255, 255, 255);"]] 541 541 544 + 545 + 546 + 542 542 == 1.7 Example 7: Schneider Electric PLC M221 with RS485-BL == 543 543 544 544