Last modified by Karry Zhuang on 2024/07/11 11:58
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,4 +1,5 @@ 1 -**Table of Contents:** 1 +(% class="wikigeneratedid" %) 2 + **Contents:** 2 2 3 3 {{toc/}} 4 4 ... ... @@ -9,13 +9,11 @@ 9 9 10 10 = **1. Introduction** = 11 11 12 - 13 13 This article provide the examples for RS485-LN to connect to different type of RS485 sensors. 14 14 15 15 16 16 == **1.1 Example 1: Connect to Leak relay and VFD** == 17 17 18 - 19 19 This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to Relay and VFD and communicate with Mobile. The structure is like below: 20 20 21 21 [[image:image-20220527091852-1.png]] ... ... @@ -29,18 +29,18 @@ 29 29 Connection 30 30 31 31 32 - (% style="color:blue" %)**Related documents:**31 +Related documents: 33 33 34 -* System Structure:[[Solar Pump with Dragino>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Relay_VFD/||style="background-color: rgb(255, 255, 255);"]]35 -* Explanation on how to integrate to Node-red and to the Mobile Phone, and with link to the Github code:[[Configure Manual>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Relay_VFD/||style="background-color:rgb(255,255,255);"]]33 +* [[Solar Pump with Dragino>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Relay_VFD/]] : System Structure 34 +* [[Configure Manual>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Relay_VFD/]] : Explanation on how to integrate to Node-red and to the Mobile Phone, and with link to the Github code. 36 36 * [[Video Demo>>url:https://www.youtube.com/watch?v=TAFZ5eaf-MY&t=6s&ab_channel=XavierFlorensaBerenguer]] 37 37 38 -== **1.2 Example 2: Connect to Pulse Counter** == 39 39 40 40 39 +== **1.2 Example 2: Connect to Pulse Counter** == 40 + 41 41 This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to Pulse Counter and communicate with Mobile. This example and example 2 compose the structure for a farm IoT solution. The structure is like below: 42 42 43 - 44 44 [[image:image-20220527092058-3.png]] 45 45 46 46 Connection ... ... @@ -52,21 +52,17 @@ 52 52 Connection 53 53 54 54 55 -(% style="color:blue" %)**Related documents:** 56 - 57 -* Configure Document: [[Pickdata MIO40 water pulse counter to LoRa with Dragino RS485-LN>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Pulse-Counter/]] 54 +* [[Pickdata MIO40 water pulse counter to LoRa with Dragino RS485-LN>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Pulse-Counter/]] : Configure Document 58 58 * [[Dragino Solution in Farm>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/&file=Dragino%20on%20Farms.pptx]] 59 59 57 +== == 60 60 61 - 62 62 == **1.3 Example3: Use RS485-LN with energy meters** == 63 63 64 - 65 65 === **1.3.1 OverView** === 66 66 67 - 68 68 ((( 69 - (% style="color:red" %)**Note**:The specifications of each energy meter are different, please refer to your own energy meter specifications.64 +**Note**:The specifications of each energy meter are different, please refer to your own energy meter specifications. 70 70 ))) 71 71 72 72 ((( ... ... @@ -80,9 +80,7 @@ 80 80 81 81 82 82 ((( 83 -(% style="color:blue" %)**How to connect with Energy Meter:** 84 - 85 - 78 +How to connect with Energy Meter: 86 86 ))) 87 87 88 88 ((( ... ... @@ -110,6 +110,7 @@ 110 110 Connection2 111 111 112 112 106 + 113 113 [[image:image-20220527092555-7.png]] 114 114 115 115 Connection3 ... ... @@ -117,13 +117,15 @@ 117 117 118 118 === **1.3.2 How to use the parameters of the energy meter and MODBUS commands** === 119 119 120 - 121 121 If the user needs to read the parameters of the electric energy meter and use the modbus command,please refer to the appendix of the MODBUS communication protocol in the user manual of the energy meter. 122 122 123 123 [[image:image-20220601143257-10.png]] 124 124 125 125 126 -(% style="color:blue" %)**Example:**(%%) AT+COMMAND1=01 03 00 00 00 01 84 0A 119 +(% class="box infomessage" %) 120 +((( 121 +**Example:** AT+COMMAND1=01 03 00 00 00 01 84 0A 122 +))) 127 127 128 128 * The first byte : slave address code (=001~247) 129 129 * The second byte : read register value function code ... ... @@ -132,12 +132,12 @@ 132 132 * 7th and 8th bytes: CRC16 checksum from bytes 1 to 6. 133 133 134 134 ((( 135 - 136 - 137 - 138 138 How to parse the reading of the return command of the parameter: 132 +))) 139 139 140 -(% style="color:blue" %)**Example:**(%%) RETURN1:01 03 02 08 FD 7E 05 134 +(% class="box infomessage" %) 135 +((( 136 +**Example:** RETURN1:01 03 02 08 FD 7E 05 141 141 ))) 142 142 143 143 * The first byte ARD: slave address code (=001~254) ... ... @@ -150,22 +150,17 @@ 150 150 (% class="wikigeneratedid" %) 151 151 ((( 152 152 153 - 154 - 155 - 156 156 ))) 157 157 158 158 === **1.3.3 How to configure RS485-LN and parse output commands** === 159 159 160 - 161 161 RS485-LN provides two configuration methods: AT COMMAND and DOWNLINK. 162 162 163 163 164 -==== **1.3.3.1 via AT COMMAND** ==== 156 +==== **1.3.3.1 via AT COMMAND:** ==== 165 165 158 +First, we can use **AT+CFGDEV** to get the return value, and we can also judge whether the input parameters are correct. 166 166 167 -First, we can use (% style="color:blue" %)**AT+CFGDEV**(%%) to get the return value, and we can also judge whether the input parameters are correct. 168 - 169 169 ((( 170 170 If the configured parameters and commands are incorrect, the return value is not obtained. 171 171 ))) ... ... @@ -177,7 +177,7 @@ 177 177 178 178 (% class="box infomessage" %) 179 179 ((( 180 - **AT+DATACUTx**:This command defines how to handle the return from AT+COMMANDx, max reture length is 40 bytes. AT+DATACUTx=a,b,c171 + AT+DATACUTx : This command defines how to handle the return from AT+COMMANDx, max reture length is 40 bytes. AT+DATACUTx=a,b,c 181 181 ))) 182 182 183 183 a: length for the return of AT+COMMAND ... ... @@ -214,49 +214,49 @@ 214 214 ))) 215 215 216 216 ((( 217 -(% style="color:b lue" %)**Example**:208 +(% style="color:#4f81bd" %)**Example**: 218 218 219 - (% style="color:red" %)**CMD1:**(%%)Read current data with MODBUS command. address:210 +CMD1:Read current data with MODBUS command. address:0x03 AT+COMMAND1= 01 03 00 03 00 01,1 220 220 ))) 221 221 222 222 ((( 223 -RETURN1: 214 +RETURN1:01 03 02 00 02 39 85 00 00(return data) 224 224 ))) 225 225 226 226 ((( 227 -AT+DATACUT1: 218 +AT+DATACUT1:9,1,4+5+6+7 Take the return value 00 02 39 85 as the valid value of reading current data and used to splice payload. 228 228 229 229 230 230 ))) 231 231 232 232 ((( 233 - (% style="color:red" %)**CMD2:**(%%)Read voltage data with MODBUS command. address:224 +CMD2:Read voltage data with MODBUS command. address:0x00 AT+COMMAND2= 01 03 00 00 00 01,1 234 234 ))) 235 235 236 236 ((( 237 -RETURN2: 228 +RETURN2:01 03 02 08 DC BE 1D(return data) 238 238 ))) 239 239 240 240 ((( 241 -AT+DATACUT2: 232 +AT+DATACUT2:7,1,4+5 Take the return value 08 DC as the valid value of reading voltage data and used to splice payload. 242 242 243 243 244 244 ))) 245 245 246 246 ((( 247 - (% style="color:red" %)**CMD3:**(%%)Read total active energy data with MODBUS command. address:238 +CMD3:Read total active energy data with MODBUS command. address:0x0031 AT+COMMAND3= 01 03 00 31 00 02,1 248 248 ))) 249 249 250 250 ((( 251 -RETURN3: 242 +RETURN3:01 03 04 00 00 00 44 FA 00(return data) 252 252 ))) 253 253 254 254 ((( 255 -AT+DATACUT3: 246 +AT+DATACUT3:9,1,4+5+6+7 Take the return value 00 00 00 44 as the valid value of reading total active energy data and used to splice payload. 256 256 ))) 257 257 258 258 ((( 259 -Payload: 250 +Payload:01 00 02 39 85 08 DC 00 00 00 44 260 260 ))) 261 261 262 262 [[image:image-20220601142936-6.png]] ... ... @@ -267,6 +267,7 @@ 267 267 (% style="color:#4f81bd" %)**01 is device address,00 02 is the current, 08 DC is the voltage,00 00 00 44 is the total active energy.** 268 268 269 269 261 + 270 270 [[image:image-20220601143642-2.png]] 271 271 272 272 AT COMMAND ... ... @@ -274,7 +274,6 @@ 274 274 275 275 ==== **1.3.3.2 via LoRaWAN DOWNLINK** ==== 276 276 277 - 278 278 [[image:image-20220527093358-15.png]] 279 279 280 280 ((( ... ... @@ -297,7 +297,7 @@ 297 297 ))) 298 298 299 299 ((( 300 - (% style="color:red" %)Note: if user use AT+COMMANDx to add a new command, he also need to send AT+DATACUTx downlink.291 +Note: if user use AT+COMMANDx to add a new command, he also need to send AT+DATACUTx downlink. 301 301 ))) 302 302 303 303 ((( ... ... @@ -335,7 +335,7 @@ 335 335 ((( 336 336 337 337 338 -(% style="color:b lue" %)**Example:**329 +(% style="color:#4f81bd" %)**Example:** 339 339 ))) 340 340 341 341 ((( ... ... @@ -391,8 +391,6 @@ 391 391 392 392 ((( 393 393 check digit: Even 394 - 395 - 396 396 ))) 397 397 398 398 [[image:image-20220527093708-21.png]] ... ... @@ -409,18 +409,14 @@ 409 409 410 410 ((( 411 411 The configuration command is consistent with the AT command, input the hexadecimal command directly into the serial port, and the serial port will output the command. 412 - 413 - 414 414 ))) 415 415 416 416 ((( 417 -(% style="color:b lue" %)**Example:** (%%)input:01 03 00 31 00 02 95 c4404 +(% style="color:#4f81bd" %)**Example:** (%%)input:01 03 00 31 00 02 95 c4 418 418 ))) 419 419 420 420 ((( 421 421 output:01 03 04 00 00 00 42 7A 02 422 - 423 - 424 424 ))) 425 425 426 426 [[image:image-20220527093821-23.png]] ... ... @@ -430,7 +430,6 @@ 430 430 431 431 === **1.3.5 How to configure multiple devices and modify device addresses** === 432 432 433 - 434 434 If users need to read the parameters of multiple energy meters, they need to modify the device address, because the default device address of each energy meter is 01. 435 435 436 436 ((( ... ... @@ -442,7 +442,7 @@ 442 442 [[image:image-20220601142044-1.png]] 443 443 444 444 445 - (% style="color:blue" %)**Example**(%%):429 +**Example**:These two meters are examples of setting parameters and device addresses. 446 446 447 447 [[image:image-20220527093950-25.png]] 448 448 ... ... @@ -449,7 +449,6 @@ 449 449 450 450 [[image:image-20220527094028-26.png]] 451 451 452 - 453 453 ((( 454 454 ((( 455 455 First of all, since the default device address of the energy meter is 01, the configuration of two energy meters will conflict, so we first connect an energy meter and configure the device address. ... ... @@ -458,7 +458,7 @@ 458 458 459 459 ((( 460 460 ((( 461 -We can use **AT+CFGDEV**to set the device address.444 +We can use AT+CFGDEV to set the device address. 462 462 ))) 463 463 ))) 464 464 ... ... @@ -470,7 +470,6 @@ 470 470 471 471 [[image:image-20220601142354-2.png]] 472 472 473 - 474 474 (% class="box infomessage" %) 475 475 ((( 476 476 **AT+CFGDEV:01 10 00 61 00 01 02 00 02,1** ... ... @@ -501,47 +501,43 @@ 501 501 502 502 [[image:image-20220601142607-4.png]] 503 503 504 - 505 505 **PAYLOAD:01 08 DF 43 62** 506 506 507 507 * 08 DF is the valid value of the meter with device address 02. 508 508 * 43 62 is the valid value of the meter with device address 01. 509 509 510 -== 1.4 Example 4: Circuit Breaker Remote Open Close == 511 511 512 512 513 - Thisinstructionis provided by Xavier Florensa Berenguer from[[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]].It is to show how to use RS485-LNto connect to SCHNEIDER SMART and Monitorandcontrolyourcabinetremotelywith no wires andwith Dragino RS485-LN LoRaWAN technology.493 +== 1.4 Example 4: Circuit Breaker Remote Open Close == 514 514 515 -The structure is like below: 495 +This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to SCHNEIDER SMART and Monitor and control your cabinet remotely with no wires and with Dragino RS485-LN LoRaWAN technology. The structure is like below: 516 516 517 517 [[image:image-20220527094330-30.png]] 518 518 519 519 Connection 520 520 501 +* [[Circuit Breaker Remote Open Close>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Circuit_Breaker_Remote_Open_Close/]] : Configure Documen 521 521 522 -* Configure Documen: [[Circuit Breaker Remote Open Close>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Circuit_Breaker_Remote_Open_Close/]] 523 - 524 524 == 1.5 Example 5: SEM Three Energy Meter with RS485-BL or RS485-LN == 525 525 526 - 527 527 This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-BL to connect to SEM Three Energy Meter and send the data to mobile phone for remote minitor. The structure is like below: 528 528 529 -* Configure Document For RS485-BL: [[Connect to SEM Three>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/RS485-BL/Application_Note/&file=Dragino%20RS485BL%20and%20pickdata%20SEM%20Three%20v1.pdf||style="background-color: rgb(255, 255, 255);"]] 530 -* Configure Document for RS485-LN: [[Connect to SEM Three>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/SEM_Three_Energy_Meter/&file=SEM%20three%20and%20Dragino%20RS485-LN%20v1.pdf]] 507 +* [[Connect to SEM Three>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/RS485-BL/Application_Note/&file=Dragino%20RS485BL%20and%20pickdata%20SEM%20Three%20v1.pdf]] : Configure Document For RS485-BL 531 531 532 - ==1.6 Example6:CEMC31485-T1-MIDEnergywith==509 +* [[Connect to SEM Three>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/SEM_Three_Energy_Meter/&file=SEM%20three%20and%20Dragino%20RS485-LN%20v1.pdf]] : Configure Document for RS485-LN 533 533 534 534 512 +== 1.6 Example 6:CEM C31 485-T1-MID Energy Meter with RS485-LN == 513 + 535 535 This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to CEM C31 485-T1-MID and send the data for remote minitor. The structure is like below: 536 536 537 -* Configure Document For RS485-LN:[[CEM C31 485-T1-MID>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/ELECTRICAL%20CABINET/&file=ELECTRICAL%20CABINET%20READINGS.pdf||style="background-color:rgb(255, 255, 255);"]]516 +* [[CEM C31 485-T1-MID>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/ELECTRICAL%20CABINET/&file=ELECTRICAL%20CABINET%20READINGS.pdf]] : Configure Document For RS485-LN 538 538 539 -== 1.7 Example 7: Schneider Electric PLC M221 with RS485-BL == 540 540 519 +== 1.7 Example 7:Schneider Electric PLC M221 with RS485-BL == 541 541 542 542 [[image:image-20220527094556-31.png]] 543 543 544 544 Network Structure 545 545 546 - 547 547 * [[Reference Instruction>>url:https://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Schneider%20Electric%20PLC/]]