... ... @@ -1,4 +1,6 @@
1 -**Table of Contents:**
1 +(% class="wikigeneratedid" %)
2 +*
3 +** Table of** **Contents:
2 2  
3 3  {{toc/}}
4 4  
... ... @@ -29,10 +29,10 @@
29 29  Connection
30 30  
31 31  
32 -(% style="color:blue" %)**Related documents:**
34 +Related documents:
33 33  
34 -* System Structure:  [[Solar Pump with Dragino>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Relay_VFD/||style="background-color: rgb(255, 255, 255);"]]
35 -* Explanation on how to integrate to Node-red and to the Mobile Phone, and with link to the Github code:  [[Configure Manual>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Relay_VFD/||style="background-color: rgb(255, 255, 255);"]]
36 +* [[Solar Pump with Dragino>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Relay_VFD/]] : System Structure
37 +* [[Configure Manual>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Relay_VFD/]] : Explanation on how to integrate to Node-red and to the Mobile Phone, and with link to the Github code.
36 36  * [[Video Demo>>url:https://www.youtube.com/watch?v=TAFZ5eaf-MY&t=6s&ab_channel=XavierFlorensaBerenguer]]
37 37  
38 38  == **1.2 Example 2: Connect to Pulse Counter** ==
... ... @@ -52,16 +52,11 @@
52 52  Connection
53 53  
54 54  
55 -(% style="color:blue" %)**Related documents:**
56 -
57 -* Configure Document:  [[Pickdata MIO40 water pulse counter to LoRa with Dragino RS485-LN>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Pulse-Counter/]]
57 +* Configure Document: [[Pickdata MIO40 water pulse counter to LoRa with Dragino RS485-LN>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Pulse-Counter/]]
58 58  * [[Dragino Solution in Farm>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/&file=Dragino%20on%20Farms.pptx]]
59 59  
60 -
61 -
62 62  == **1.3 Example3: Use RS485-LN with energy meters** ==
63 63  
64 -
65 65  === **1.3.1 OverView** ===
66 66  
67 67  
... ... @@ -80,7 +80,7 @@
80 80  
81 81  
82 82  (((
83 -(% style="color:blue" %)**How to connect with Energy Meter:**
80 +**How to connect with Energy Meter:**
84 84  
85 85  
86 86  )))
... ... @@ -110,6 +110,7 @@
110 110  Connection2
111 111  
112 112  
110 +
113 113  [[image:image-20220527092555-7.png]]
114 114  
115 115  Connection3
... ... @@ -216,7 +216,7 @@
216 216  (((
217 217  (% style="color:blue" %)**Example**:
218 218  
219 -(% style="color:red" %)**CMD1:**(%%) Read current data with MODBUS command. address: 0x03 AT+COMMAND1= 01 03 00 03 00 01,1
217 +CMD1: Read current data with MODBUS command. address: 0x03 AT+COMMAND1= 01 03 00 03 00 01,1
220 220  )))
221 221  
222 222  (((
... ... @@ -230,7 +230,7 @@
230 230  )))
231 231  
232 232  (((
233 -(% style="color:red" %)**CMD2: **(%%)Read voltage data with MODBUS command. address: 0x00 AT+COMMAND2= 01 03 00 00 00 01,1
231 +CMD2: Read voltage data with MODBUS command. address: 0x00 AT+COMMAND2= 01 03 00 00 00 01,1
234 234  )))
235 235  
236 236  (((
... ... @@ -244,7 +244,7 @@
244 244  )))
245 245  
246 246  (((
247 -(% style="color:red" %)**CMD3:**(%%) Read total active energy data with MODBUS command. address: 0x0031 AT+COMMAND3= 01 03 00 31 00 02,1
245 +CMD3: Read total active energy data with MODBUS command. address: 0x0031 AT+COMMAND3= 01 03 00 31 00 02,1
248 248  )))
249 249  
250 250  (((
... ... @@ -507,6 +507,9 @@
507 507  * 08 DF is the valid value of the meter with device address 02.
508 508  * 43 62 is the valid value of the meter with device address 01.
509 509  
508 +
509 +
510 +
510 510  == 1.4 Example 4: Circuit Breaker Remote Open Close ==
511 511  
512 512  
... ... @@ -521,6 +521,9 @@
521 521  
522 522  * Configure Documen:  [[Circuit Breaker Remote Open Close>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Circuit_Breaker_Remote_Open_Close/]]
523 523  
525 +
526 +
527 +
524 524  == 1.5 Example 5: SEM Three Energy Meter with RS485-BL or RS485-LN ==
525 525  
526 526  
... ... @@ -529,16 +529,22 @@
529 529  * Configure Document For RS485-BL:  [[Connect to SEM Three>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/RS485-BL/Application_Note/&file=Dragino%20RS485BL%20and%20pickdata%20SEM%20Three%20v1.pdf||style="background-color: rgb(255, 255, 255);"]]
530 530  * Configure Document for RS485-LN:  [[Connect to SEM Three>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/SEM_Three_Energy_Meter/&file=SEM%20three%20and%20Dragino%20RS485-LN%20v1.pdf]]
531 531  
532 -== 1.6 Example 6: CEM C31 485-T1-MID Energy Meter with RS485-LN ==
533 533  
534 534  
538 +
539 +== 1.6 Example 6:CEM C31 485-T1-MID Energy Meter with RS485-LN ==
540 +
541 +
535 535  This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to CEM C31 485-T1-MID and send the data for remote minitor. The structure is like below:
536 536  
537 537  * Configure Document For RS485-LN:  [[CEM C31 485-T1-MID>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/ELECTRICAL%20CABINET/&file=ELECTRICAL%20CABINET%20READINGS.pdf||style="background-color: rgb(255, 255, 255);"]]
538 538  
539 -== 1.7 Example 7: Schneider Electric PLC M221 with RS485-BL ==
540 540  
541 541  
548 +
549 +== 1.7 Example 7:Schneider Electric PLC M221 with RS485-BL ==
550 +
551 +
542 542  [[image:image-20220527094556-31.png]]
543 543  
544 544  Network Structure