Last modified by Karry Zhuang on 2024/07/11 11:58
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,4 +1,6 @@ 1 -**Table of Contents:** 1 +(% class="wikigeneratedid" %) 2 +* 3 +** Table of** **Contents: 2 2 3 3 {{toc/}} 4 4 ... ... @@ -29,10 +29,10 @@ 29 29 Connection 30 30 31 31 32 - (% style="color:blue" %)**Related documents:**34 +Related documents: 33 33 34 -* System Structure:[[Solar Pump with Dragino>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Relay_VFD/||style="background-color: rgb(255, 255, 255);"]]35 -* Explanation on how to integrate to Node-red and to the Mobile Phone, and with link to the Github code:[[Configure Manual>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Relay_VFD/||style="background-color:rgb(255,255,255);"]]36 +* [[Solar Pump with Dragino>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Relay_VFD/]] : System Structure 37 +* [[Configure Manual>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Relay_VFD/]] : Explanation on how to integrate to Node-red and to the Mobile Phone, and with link to the Github code. 36 36 * [[Video Demo>>url:https://www.youtube.com/watch?v=TAFZ5eaf-MY&t=6s&ab_channel=XavierFlorensaBerenguer]] 37 37 38 38 == **1.2 Example 2: Connect to Pulse Counter** == ... ... @@ -52,16 +52,11 @@ 52 52 Connection 53 53 54 54 55 -(% style="color:blue" %)**Related documents:** 56 - 57 -* Configure Document: [[Pickdata MIO40 water pulse counter to LoRa with Dragino RS485-LN>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Pulse-Counter/]] 57 +* Configure Document: [[Pickdata MIO40 water pulse counter to LoRa with Dragino RS485-LN>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Pulse-Counter/]] 58 58 * [[Dragino Solution in Farm>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/&file=Dragino%20on%20Farms.pptx]] 59 59 60 - 61 - 62 62 == **1.3 Example3: Use RS485-LN with energy meters** == 63 63 64 - 65 65 === **1.3.1 OverView** === 66 66 67 67 ... ... @@ -80,7 +80,7 @@ 80 80 81 81 82 82 ((( 83 - (% style="color:blue" %)**How to connect with Energy Meter:**80 +**How to connect with Energy Meter:** 84 84 85 85 86 86 ))) ... ... @@ -110,6 +110,7 @@ 110 110 Connection2 111 111 112 112 110 + 113 113 [[image:image-20220527092555-7.png]] 114 114 115 115 Connection3 ... ... @@ -216,7 +216,7 @@ 216 216 ((( 217 217 (% style="color:blue" %)**Example**: 218 218 219 - (% style="color:red" %)**CMD1:**(%%)Read current data with MODBUS command. address: 0x03 AT+COMMAND1= 01 03 00 03 00 01,1217 +CMD1: Read current data with MODBUS command. address: 0x03 AT+COMMAND1= 01 03 00 03 00 01,1 220 220 ))) 221 221 222 222 ((( ... ... @@ -230,7 +230,7 @@ 230 230 ))) 231 231 232 232 ((( 233 - (% style="color:red" %)**CMD2:**(%%)Read voltage data with MODBUS command. address: 0x00 AT+COMMAND2= 01 03 00 00 00 01,1231 +CMD2: Read voltage data with MODBUS command. address: 0x00 AT+COMMAND2= 01 03 00 00 00 01,1 234 234 ))) 235 235 236 236 ((( ... ... @@ -244,7 +244,7 @@ 244 244 ))) 245 245 246 246 ((( 247 - (% style="color:red" %)**CMD3:**(%%)Read total active energy data with MODBUS command. address: 0x0031 AT+COMMAND3= 01 03 00 31 00 02,1245 +CMD3: Read total active energy data with MODBUS command. address: 0x0031 AT+COMMAND3= 01 03 00 31 00 02,1 248 248 ))) 249 249 250 250 ((( ... ... @@ -507,6 +507,9 @@ 507 507 * 08 DF is the valid value of the meter with device address 02. 508 508 * 43 62 is the valid value of the meter with device address 01. 509 509 508 + 509 + 510 + 510 510 == 1.4 Example 4: Circuit Breaker Remote Open Close == 511 511 512 512 ... ... @@ -519,29 +519,32 @@ 519 519 Connection 520 520 521 521 522 -* Configure Documen: 523 +* Configure Documen: [[Circuit Breaker Remote Open Close>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Circuit_Breaker_Remote_Open_Close/]] 523 523 525 + 526 + 527 + 524 524 == 1.5 Example 5: SEM Three Energy Meter with RS485-BL or RS485-LN == 525 525 526 526 527 527 This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-BL to connect to SEM Three Energy Meter and send the data to mobile phone for remote minitor. The structure is like below: 528 528 529 -* Configure Document For RS485-BL: 530 -* Configure Document for RS485-LN: 533 +* Configure Document For RS485-BL: [[Connect to SEM Three>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/RS485-BL/Application_Note/&file=Dragino%20RS485BL%20and%20pickdata%20SEM%20Three%20v1.pdf||style="background-color: rgb(255, 255, 255);"]] 534 +* Configure Document for RS485-LN: [[Connect to SEM Three>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/SEM_Three_Energy_Meter/&file=SEM%20three%20and%20Dragino%20RS485-LN%20v1.pdf]] 531 531 532 -== 1.6 Example 6: CEM C31 485-T1-MID Energy Meter with RS485-LN == 533 533 534 534 535 -This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to CEM C31 485-T1-MID and send the data for remote minitor. The structure is like below: 536 536 537 - *ConfigureDocumentFor RS485-LN:[[CEM C31 485-T1-MID>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/ELECTRICAL%20CABINET/&file=ELECTRICAL%20CABINET%20READINGS.pdf||style="background-color: rgb(255, 255, 255);"]]539 +== 1.6 Example 6:CEM C31 485-T1-MID Energy Meter with RS485-LN == 538 538 539 - ==1.7Example7:Schneider ElectricPLCM221withRS485-BL==541 +This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to CEM C31 485-T1-MID and send the data for remote minitor. The structure is like below: 540 540 543 +* [[CEM C31 485-T1-MID>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/ELECTRICAL%20CABINET/&file=ELECTRICAL%20CABINET%20READINGS.pdf]] : Configure Document For RS485-LN 541 541 545 +== 1.7 Example 7:Schneider Electric PLC M221 with RS485-BL == 546 + 542 542 [[image:image-20220527094556-31.png]] 543 543 544 544 Network Structure 545 545 546 - 547 547 * [[Reference Instruction>>url:https://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Schneider%20Electric%20PLC/]]