Last modified by Karry Zhuang on 2024/07/11 11:58
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -13,11 +13,13 @@ 13 13 This article provide the examples for RS485-LN to connect to different type of RS485 sensors. 14 14 15 15 16 + 16 16 == **1.1 Example 1: Connect to Leak relay and VFD** == 17 17 18 18 19 19 This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to Relay and VFD and communicate with Mobile. The structure is like below: 20 20 22 + 21 21 [[image:image-20220527091852-1.png]] 22 22 23 23 Connection ... ... @@ -31,10 +31,12 @@ 31 31 32 32 (% style="color:blue" %)**Related documents:** 33 33 34 -* System Structure: [[Solar Pump with Dragino>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Relay_VFD/||style="background-color: rgb(255, 255, 255);"]] 35 -* Explanation on how to integrate to Node-red and to the Mobile Phone, and with link to the Github code: [[Configure Manual>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Relay_VFD/||style="background-color: rgb(255, 255, 255);"]] 36 +* System Structure: [[Solar Pump with Dragino>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Relay_VFD/||_mstmutation="1" style="background-color: rgb(255, 255, 255);"]] 37 +* Explanation on how to integrate to Node-red and to the Mobile Phone, and with link to the Github code: [[Configure Manual>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Relay_VFD/||_mstmutation="1" style="background-color: rgb(255, 255, 255);"]] 36 36 * [[Video Demo>>url:https://www.youtube.com/watch?v=TAFZ5eaf-MY&t=6s&ab_channel=XavierFlorensaBerenguer]] 37 37 40 + 41 + 38 38 == **1.2 Example 2: Connect to Pulse Counter** == 39 39 40 40 ... ... @@ -54,10 +54,11 @@ 54 54 55 55 (% style="color:blue" %)**Related documents:** 56 56 57 -* Configure Document: [[Pickdata MIO40 water pulse counter to LoRa with Dragino RS485-LN>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Pulse-Counter/]] 61 +* Configure Document: [[Pickdata MIO40 water pulse counter to LoRa with Dragino RS485-LN>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Pulse-Counter/||_mstmutation="1"]] 58 58 * [[Dragino Solution in Farm>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/&file=Dragino%20on%20Farms.pptx]] 59 59 60 60 65 + 61 61 == **1.3 Example3: Use RS485-LN with energy meters** == 62 62 63 63 ... ... @@ -65,7 +65,7 @@ 65 65 66 66 67 67 ((( 68 -(% style="color:red" %)**Note**:The specifications of each energy meter are different, please refer to your own energy meter specifications. 73 +(% style="color:red" %)**Note**:**The specifications of each energy meter are different, please refer to your own energy meter specifications.** 69 69 ))) 70 70 71 71 ((( ... ... @@ -102,6 +102,8 @@ 102 102 103 103 ((( 104 104 Once there is power, the RS485-LN will be on. 110 + 111 + 105 105 ))) 106 106 107 107 [[image:image-20220527092514-6.png]] ... ... @@ -109,11 +109,13 @@ 109 109 Connection2 110 110 111 111 119 + 112 112 [[image:image-20220527092555-7.png]] 113 113 114 114 Connection3 115 115 116 116 125 + 117 117 === **1.3.2 How to use the parameters of the energy meter and MODBUS commands** === 118 118 119 119 ... ... @@ -160,6 +160,7 @@ 160 160 RS485-LN provides two configuration methods: AT COMMAND and DOWNLINK. 161 161 162 162 172 + 163 163 ==== **1.3.3.1 via AT COMMAND** ==== 164 164 165 165 ... ... @@ -176,7 +176,7 @@ 176 176 177 177 (% class="box infomessage" %) 178 178 ((( 179 - **AT+DATACUTx **: This command defines how to handle the return from AT+COMMANDx, max reture length is 40 bytes. AT+DATACUTx=a,b,c 189 + (% _mstmutation="1" %)**AT+DATACUTx **(%%): This command defines how to handle the return from AT+COMMANDx, max reture length is 40 bytes. AT+DATACUTx=a,b,c 180 180 ))) 181 181 182 182 a: length for the return of AT+COMMAND ... ... @@ -210,6 +210,8 @@ 210 210 211 211 ((( 212 212 223 + 224 + 213 213 ))) 214 214 215 215 ((( ... ... @@ -263,6 +263,7 @@ 263 263 AT COMMAND 264 264 265 265 278 + 266 266 (% style="color:#4f81bd" %)**01 is device address,00 02 is the current, 08 DC is the voltage,00 00 00 44 is the total active energy.** 267 267 268 268 ... ... @@ -271,6 +271,7 @@ 271 271 AT COMMAND 272 272 273 273 287 + 274 274 ==== **1.3.3.2 via LoRaWAN DOWNLINK** ==== 275 275 276 276 ... ... @@ -296,7 +296,9 @@ 296 296 ))) 297 297 298 298 ((( 299 -(% style="color:red" %)Note: if user use AT+COMMANDx to add a new command, he also need to send AT+DATACUTx downlink. 313 +(% style="color:red" %)**Note: if user use AT+COMMANDx to add a new command, he also need to send AT+DATACUTx downlink.** 314 + 315 + 300 300 ))) 301 301 302 302 ((( ... ... @@ -370,8 +370,10 @@ 370 370 DOWNLINK 371 371 372 372 389 + 373 373 === **1.3.4 How to configure and output commands for RS485 to USB** === 374 374 392 + 375 375 ((( 376 376 This step is not necessary, it is just to show how to use a normal RS485 to USB adapter to connect to the meter to check the input and output. This can be used to test the connection and RS485 command of the meter without RS485-LN. 377 377 ))) ... ... @@ -427,6 +427,7 @@ 427 427 USB 428 428 429 429 448 + 430 430 === **1.3.5 How to configure multiple devices and modify device addresses** === 431 431 432 432 ... ... @@ -457,7 +457,7 @@ 457 457 458 458 ((( 459 459 ((( 460 -We can use **AT+CFGDEV** to set the device address. 479 +We can use (% style="color:blue" %)**AT+CFGDEV**(%%) to set the device address. 461 461 ))) 462 462 ))) 463 463 ... ... @@ -501,7 +501,7 @@ 501 501 [[image:image-20220601142607-4.png]] 502 502 503 503 504 -**PAYLOAD:01 08 DF 43 62** 523 +(% style="color:blue" %)**PAYLOAD: 01 08 DF 43 62** 505 505 506 506 * 08 DF is the valid value of the meter with device address 02. 507 507 * 43 62 is the valid value of the meter with device address 01. ... ... @@ -518,23 +518,26 @@ 518 518 Connection 519 519 520 520 521 -* Configure Documen: [[Circuit Breaker Remote Open Close>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Circuit_Breaker_Remote_Open_Close/]] 540 +* Configure Documen: [[Circuit Breaker Remote Open Close>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Circuit_Breaker_Remote_Open_Close/||_mstmutation="1"]] 522 522 542 + 523 523 == 1.5 Example 5: SEM Three Energy Meter with RS485-BL or RS485-LN == 524 524 525 525 526 526 This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-BL to connect to SEM Three Energy Meter and send the data to mobile phone for remote minitor. The structure is like below: 527 527 528 -* Configure Document For RS485-BL: [[Connect to SEM Three>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/RS485-BL/Application_Note/&file=Dragino%20RS485BL%20and%20pickdata%20SEM%20Three%20v1.pdf||style="background-color: rgb(255, 255, 255);"]] 529 -* Configure Document for RS485-LN: [[Connect to SEM Three>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/SEM_Three_Energy_Meter/&file=SEM%20three%20and%20Dragino%20RS485-LN%20v1.pdf]] 548 +* Configure Document For RS485-BL: [[Connect to SEM Three>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/RS485-BL/Application_Note/&file=Dragino%20RS485BL%20and%20pickdata%20SEM%20Three%20v1.pdf||_mstmutation="1" style="background-color: rgb(255, 255, 255);"]] 549 +* Configure Document for RS485-LN: [[Connect to SEM Three>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/SEM_Three_Energy_Meter/&file=SEM%20three%20and%20Dragino%20RS485-LN%20v1.pdf||_mstmutation="1"]] 530 530 551 + 531 531 == 1.6 Example 6: CEM C31 485-T1-MID Energy Meter with RS485-LN == 532 532 533 533 534 534 This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to CEM C31 485-T1-MID and send the data for remote minitor. The structure is like below: 535 535 536 -* Configure Document For RS485-LN: [[CEM C31 485-T1-MID>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/ELECTRICAL%20CABINET/&file=ELECTRICAL%20CABINET%20READINGS.pdf||style="background-color: rgb(255, 255, 255);"]] 557 +* Configure Document For RS485-LN: [[CEM C31 485-T1-MID>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/ELECTRICAL%20CABINET/&file=ELECTRICAL%20CABINET%20READINGS.pdf||_mstmutation="1" style="background-color: rgb(255, 255, 255);"]] 537 537 559 + 538 538 == 1.7 Example 7: Schneider Electric PLC M221 with RS485-BL == 539 539 540 540