Last modified by Karry Zhuang on 2024/07/11 11:58
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Xiaoling1 +XWiki.Bei - Content
-
... ... @@ -31,8 +31,8 @@ 31 31 32 32 (% style="color:blue" %)**Related documents:** 33 33 34 -* System Structure: [[Solar Pump with Dragino>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Relay_VFD/||style="background-color: rgb(255, 255, 255);"]] 35 -* Explanation on how to integrate to Node-red and to the Mobile Phone, and with link to the Github code: [[Configure Manual>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Relay_VFD/||style="background-color: rgb(255, 255, 255);"]] 34 +* System Structure: [[Solar Pump with Dragino>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Relay_VFD/||_mstmutation="1" style="background-color: rgb(255, 255, 255);"]] 35 +* Explanation on how to integrate to Node-red and to the Mobile Phone, and with link to the Github code: [[Configure Manual>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Relay_VFD/||_mstmutation="1" style="background-color: rgb(255, 255, 255);"]] 36 36 * [[Video Demo>>url:https://www.youtube.com/watch?v=TAFZ5eaf-MY&t=6s&ab_channel=XavierFlorensaBerenguer]] 37 37 38 38 ... ... @@ -55,11 +55,10 @@ 55 55 56 56 (% style="color:blue" %)**Related documents:** 57 57 58 -* Configure Document: [[Pickdata MIO40 water pulse counter to LoRa with Dragino RS485-LN>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Pulse-Counter/]] 58 +* Configure Document: [[Pickdata MIO40 water pulse counter to LoRa with Dragino RS485-LN>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Pulse-Counter/||_mstmutation="1"]] 59 59 * [[Dragino Solution in Farm>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/&file=Dragino%20on%20Farms.pptx]] 60 60 61 61 62 - 63 63 == **1.3 Example3: Use RS485-LN with energy meters** == 64 64 65 65 ... ... @@ -116,6 +116,7 @@ 116 116 Connection3 117 117 118 118 118 + 119 119 === **1.3.2 How to use the parameters of the energy meter and MODBUS commands** === 120 120 121 121 ... ... @@ -162,6 +162,7 @@ 162 162 RS485-LN provides two configuration methods: AT COMMAND and DOWNLINK. 163 163 164 164 165 + 165 165 ==== **1.3.3.1 via AT COMMAND** ==== 166 166 167 167 ... ... @@ -178,7 +178,7 @@ 178 178 179 179 (% class="box infomessage" %) 180 180 ((( 181 - **AT+DATACUTx **: This command defines how to handle the return from AT+COMMANDx, max reture length is 40 bytes. AT+DATACUTx=a,b,c 182 + (% _mstmutation="1" %)**AT+DATACUTx **(%%): This command defines how to handle the return from AT+COMMANDx, max reture length is 40 bytes. AT+DATACUTx=a,b,c 182 182 ))) 183 183 184 184 a: length for the return of AT+COMMAND ... ... @@ -217,7 +217,7 @@ 217 217 ((( 218 218 (% style="color:blue" %)**Example**: 219 219 220 -**CMD1:** Read current data with MODBUS command. address: 0x03 AT+COMMAND1= 01 03 00 03 00 01,1 221 +(% style="color:red" %)**CMD1:**(%%) Read current data with MODBUS command. address: 0x03 AT+COMMAND1= 01 03 00 03 00 01,1 221 221 ))) 222 222 223 223 ((( ... ... @@ -231,7 +231,7 @@ 231 231 ))) 232 232 233 233 ((( 234 -**CMD2: **Read voltage data with MODBUS command. address: 0x00 AT+COMMAND2= 01 03 00 00 00 01,1 235 +(% style="color:red" %)**CMD2: **(%%)Read voltage data with MODBUS command. address: 0x00 AT+COMMAND2= 01 03 00 00 00 01,1 235 235 ))) 236 236 237 237 ((( ... ... @@ -245,7 +245,7 @@ 245 245 ))) 246 246 247 247 ((( 248 -**CMD3:** Read total active energy data with MODBUS command. address: 0x0031 AT+COMMAND3= 01 03 00 31 00 02,1 249 +(% style="color:red" %)**CMD3:**(%%) Read total active energy data with MODBUS command. address: 0x0031 AT+COMMAND3= 01 03 00 31 00 02,1 249 249 ))) 250 250 251 251 ((( ... ... @@ -273,6 +273,7 @@ 273 273 AT COMMAND 274 274 275 275 277 + 276 276 ==== **1.3.3.2 via LoRaWAN DOWNLINK** ==== 277 277 278 278 ... ... @@ -298,7 +298,7 @@ 298 298 ))) 299 299 300 300 ((( 301 -(% style="color:red" %)Note: if user use AT+COMMANDx to add a new command, he also need to send AT+DATACUTx downlink. 303 +(% style="color:red" %)**Note: if user use AT+COMMANDx to add a new command, he also need to send AT+DATACUTx downlink.** 302 302 ))) 303 303 304 304 ((( ... ... @@ -372,6 +372,7 @@ 372 372 DOWNLINK 373 373 374 374 377 + 375 375 === **1.3.4 How to configure and output commands for RS485 to USB** === 376 376 377 377 ((( ... ... @@ -429,6 +429,7 @@ 429 429 USB 430 430 431 431 435 + 432 432 === **1.3.5 How to configure multiple devices and modify device addresses** === 433 433 434 434 ... ... @@ -459,7 +459,7 @@ 459 459 460 460 ((( 461 461 ((( 462 -We can use **AT+CFGDEV** to set the device address. 466 +We can use (% style="color:blue" %)**AT+CFGDEV**(%%) to set the device address. 463 463 ))) 464 464 ))) 465 465 ... ... @@ -503,7 +503,7 @@ 503 503 [[image:image-20220601142607-4.png]] 504 504 505 505 506 -**PAYLOAD:01 08 DF 43 62** 510 +(% style="color:blue" %)**PAYLOAD: 01 08 DF 43 62** 507 507 508 508 * 08 DF is the valid value of the meter with device address 02. 509 509 * 43 62 is the valid value of the meter with device address 01. ... ... @@ -521,7 +521,7 @@ 521 521 Connection 522 522 523 523 524 -* Configure Documen: [[Circuit Breaker Remote Open Close>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Circuit_Breaker_Remote_Open_Close/]] 528 +* Configure Documen: [[Circuit Breaker Remote Open Close>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Circuit_Breaker_Remote_Open_Close/||_mstmutation="1"]] 525 525 526 526 527 527 == 1.5 Example 5: SEM Three Energy Meter with RS485-BL or RS485-LN == ... ... @@ -529,8 +529,8 @@ 529 529 530 530 This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-BL to connect to SEM Three Energy Meter and send the data to mobile phone for remote minitor. The structure is like below: 531 531 532 -* Configure Document For RS485-BL: [[Connect to SEM Three>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/RS485-BL/Application_Note/&file=Dragino%20RS485BL%20and%20pickdata%20SEM%20Three%20v1.pdf||style="background-color: rgb(255, 255, 255);"]] 533 -* Configure Document for RS485-LN: [[Connect to SEM Three>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/SEM_Three_Energy_Meter/&file=SEM%20three%20and%20Dragino%20RS485-LN%20v1.pdf]] 536 +* Configure Document For RS485-BL: [[Connect to SEM Three>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/RS485-BL/Application_Note/&file=Dragino%20RS485BL%20and%20pickdata%20SEM%20Three%20v1.pdf||_mstmutation="1" style="background-color: rgb(255, 255, 255);"]] 537 +* Configure Document for RS485-LN: [[Connect to SEM Three>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/SEM_Three_Energy_Meter/&file=SEM%20three%20and%20Dragino%20RS485-LN%20v1.pdf||_mstmutation="1"]] 534 534 535 535 536 536 == 1.6 Example 6: CEM C31 485-T1-MID Energy Meter with RS485-LN == ... ... @@ -538,7 +538,7 @@ 538 538 539 539 This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to CEM C31 485-T1-MID and send the data for remote minitor. The structure is like below: 540 540 541 -* Configure Document For RS485-LN: [[CEM C31 485-T1-MID>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/ELECTRICAL%20CABINET/&file=ELECTRICAL%20CABINET%20READINGS.pdf||style="background-color: rgb(255, 255, 255);"]] 545 +* Configure Document For RS485-LN: [[CEM C31 485-T1-MID>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/ELECTRICAL%20CABINET/&file=ELECTRICAL%20CABINET%20READINGS.pdf||_mstmutation="1" style="background-color: rgb(255, 255, 255);"]] 542 542 543 543 544 544 == 1.7 Example 7: Schneider Electric PLC M221 with RS485-BL ==