<
From version < 57.17 >
edited by Xiaoling
on 2022/07/14 09:58
To version < 58.1 >
edited by Xiaoling
on 2022/07/14 10:20
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -36,6 +36,8 @@
36 36  * [[Video Demo>>url:https://www.youtube.com/watch?v=TAFZ5eaf-MY&t=6s&ab_channel=XavierFlorensaBerenguer]]
37 37  
38 38  
39 +
40 +
39 39  == **1.2 Example 2: Connect to Pulse Counter** ==
40 40  
41 41  
... ... @@ -60,6 +60,7 @@
60 60  
61 61  
62 62  
65 +
63 63  == **1.3 Example3: Use RS485-LN with energy meters** ==
64 64  
65 65  
... ... @@ -116,6 +116,7 @@
116 116  Connection3
117 117  
118 118  
122 +
119 119  === **1.3.2 How to use the parameters of the energy meter and MODBUS commands** ===
120 120  
121 121  
... ... @@ -162,6 +162,7 @@
162 162  RS485-LN provides two configuration methods: AT COMMAND and DOWNLINK.
163 163  
164 164  
169 +
165 165  ==== **1.3.3.1 via AT COMMAND** ====
166 166  
167 167  
... ... @@ -217,7 +217,7 @@
217 217  (((
218 218  (% style="color:blue" %)**Example**:
219 219  
220 -**CMD1:** Read current data with MODBUS command. address: 0x03 AT+COMMAND1= 01 03 00 03 00 01,1
225 +(% style="color:red" %)**CMD1:**(%%) Read current data with MODBUS command. address: 0x03 AT+COMMAND1= 01 03 00 03 00 01,1
221 221  )))
222 222  
223 223  (((
... ... @@ -231,7 +231,7 @@
231 231  )))
232 232  
233 233  (((
234 -**CMD2: **Read voltage data with MODBUS command. address: 0x00 AT+COMMAND2= 01 03 00 00 00 01,1
239 +(% style="color:red" %)**CMD2: **(%%)Read voltage data with MODBUS command. address: 0x00 AT+COMMAND2= 01 03 00 00 00 01,1
235 235  )))
236 236  
237 237  (((
... ... @@ -245,7 +245,7 @@
245 245  )))
246 246  
247 247  (((
248 -**CMD3:** Read total active energy data with MODBUS command. address: 0x0031 AT+COMMAND3= 01 03 00 31 00 02,1
253 +(% style="color:red" %)**CMD3:**(%%) Read total active energy data with MODBUS command. address: 0x0031 AT+COMMAND3= 01 03 00 31 00 02,1
249 249  )))
250 250  
251 251  (((
... ... @@ -273,6 +273,7 @@
273 273  AT COMMAND
274 274  
275 275  
281 +
276 276  ==== **1.3.3.2 via LoRaWAN DOWNLINK** ====
277 277  
278 278  
... ... @@ -298,7 +298,7 @@
298 298  )))
299 299  
300 300  (((
301 -(% style="color:red" %)Note: if user use AT+COMMANDx to add a new command, he also need to send AT+DATACUTx downlink.
307 +(% style="color:red" %)**Note: if user use AT+COMMANDx to add a new command, he also need to send AT+DATACUTx downlink.**
302 302  )))
303 303  
304 304  (((
... ... @@ -372,6 +372,7 @@
372 372  DOWNLINK
373 373  
374 374  
381 +
375 375  === **1.3.4 How to configure and output commands for RS485 to USB** ===
376 376  
377 377  (((
... ... @@ -429,6 +429,7 @@
429 429  USB
430 430  
431 431  
439 +
432 432  === **1.3.5 How to configure multiple devices and modify device addresses** ===
433 433  
434 434  
... ... @@ -459,7 +459,7 @@
459 459  
460 460  (((
461 461  (((
462 -We can use **AT+CFGDEV** to set the device address.
470 +We can use (% style="color:blue" %)**AT+CFGDEV**(%%) to set the device address.
463 463  )))
464 464  )))
465 465  
... ... @@ -503,12 +503,14 @@
503 503  [[image:image-20220601142607-4.png]]
504 504  
505 505  
506 -**PAYLOAD:01 08 DF 43 62**
514 +(% style="color:blue" %)**PAYLOAD: 01 08 DF 43 62**
507 507  
508 508  * 08 DF is the valid value of the meter with device address 02.
509 509  * 43 62 is the valid value of the meter with device address 01.
510 510  
511 511  
520 +
521 +
512 512  == 1.4 Example 4: Circuit Breaker Remote Open Close ==
513 513  
514 514  
... ... @@ -524,6 +524,8 @@
524 524  * Configure Documen:  [[Circuit Breaker Remote Open Close>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Circuit_Breaker_Remote_Open_Close/]]
525 525  
526 526  
537 +
538 +
527 527  == 1.5 Example 5: SEM Three Energy Meter with RS485-BL or RS485-LN ==
528 528  
529 529  
... ... @@ -533,6 +533,8 @@
533 533  * Configure Document for RS485-LN:  [[Connect to SEM Three>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/SEM_Three_Energy_Meter/&file=SEM%20three%20and%20Dragino%20RS485-LN%20v1.pdf]]
534 534  
535 535  
548 +
549 +
536 536  == 1.6 Example 6: CEM C31 485-T1-MID Energy Meter with RS485-LN ==
537 537  
538 538  
... ... @@ -541,6 +541,8 @@
541 541  * Configure Document For RS485-LN:  [[CEM C31 485-T1-MID>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/ELECTRICAL%20CABINET/&file=ELECTRICAL%20CABINET%20READINGS.pdf||style="background-color: rgb(255, 255, 255);"]]
542 542  
543 543  
558 +
559 +
544 544  == 1.7 Example 7: Schneider Electric PLC M221 with RS485-BL ==
545 545  
546 546  
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0