Last modified by Karry Zhuang on 2024/07/11 11:58
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,4 +1,6 @@ 1 -**Table of Contents:** 1 +(% class="wikigeneratedid" %) 2 +* 3 +** Table of** **Contents: 2 2 3 3 {{toc/}} 4 4 ... ... @@ -29,13 +29,12 @@ 29 29 Connection 30 30 31 31 32 - (% style="color:blue" %)**Related documents:**34 +Related documents: 33 33 34 -* System Structure:[[Solar Pump with Dragino>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Relay_VFD/||style="background-color: rgb(255, 255, 255);"]]35 -* Explanation on how to integrate to Node-red and to the Mobile Phone, and with link to the Github code:[[Configure Manual>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Relay_VFD/||style="background-color:rgb(255,255,255);"]]36 +* [[Solar Pump with Dragino>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Relay_VFD/]] : System Structure 37 +* [[Configure Manual>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Relay_VFD/]] : Explanation on how to integrate to Node-red and to the Mobile Phone, and with link to the Github code. 36 36 * [[Video Demo>>url:https://www.youtube.com/watch?v=TAFZ5eaf-MY&t=6s&ab_channel=XavierFlorensaBerenguer]] 37 37 38 - 39 39 == **1.2 Example 2: Connect to Pulse Counter** == 40 40 41 41 ... ... @@ -53,16 +53,11 @@ 53 53 Connection 54 54 55 55 56 -(% style="color:blue" %)**Related documents:** 57 - 58 -* Configure Document: [[Pickdata MIO40 water pulse counter to LoRa with Dragino RS485-LN>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Pulse-Counter/]] 57 +* Configure Document: [[Pickdata MIO40 water pulse counter to LoRa with Dragino RS485-LN>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Pulse-Counter/]] 59 59 * [[Dragino Solution in Farm>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/&file=Dragino%20on%20Farms.pptx]] 60 60 61 - 62 - 63 63 == **1.3 Example3: Use RS485-LN with energy meters** == 64 64 65 - 66 66 === **1.3.1 OverView** === 67 67 68 68 ... ... @@ -81,7 +81,7 @@ 81 81 82 82 83 83 ((( 84 - (% style="color:blue" %)**How to connect with Energy Meter:**80 +**How to connect with Energy Meter:** 85 85 86 86 87 87 ))) ... ... @@ -111,6 +111,7 @@ 111 111 Connection2 112 112 113 113 110 + 114 114 [[image:image-20220527092555-7.png]] 115 115 116 116 Connection3 ... ... @@ -217,7 +217,7 @@ 217 217 ((( 218 218 (% style="color:blue" %)**Example**: 219 219 220 - **CMD1:**Read current data with MODBUS command. address: 0x03 AT+COMMAND1= 01 03 00 03 00 01,1217 +CMD1: Read current data with MODBUS command. address: 0x03 AT+COMMAND1= 01 03 00 03 00 01,1 221 221 ))) 222 222 223 223 ((( ... ... @@ -231,7 +231,7 @@ 231 231 ))) 232 232 233 233 ((( 234 - **CMD2:**Read voltage data with MODBUS command. address: 0x00 AT+COMMAND2= 01 03 00 00 00 01,1231 +CMD2: Read voltage data with MODBUS command. address: 0x00 AT+COMMAND2= 01 03 00 00 00 01,1 235 235 ))) 236 236 237 237 ((( ... ... @@ -245,7 +245,7 @@ 245 245 ))) 246 246 247 247 ((( 248 - **CMD3:**Read total active energy data with MODBUS command. address: 0x0031 AT+COMMAND3= 01 03 00 31 00 02,1245 +CMD3: Read total active energy data with MODBUS command. address: 0x0031 AT+COMMAND3= 01 03 00 31 00 02,1 249 249 ))) 250 250 251 251 ((( ... ... @@ -509,6 +509,8 @@ 509 509 * 43 62 is the valid value of the meter with device address 01. 510 510 511 511 509 + 510 + 512 512 == 1.4 Example 4: Circuit Breaker Remote Open Close == 513 513 514 514 ... ... @@ -524,6 +524,8 @@ 524 524 * Configure Documen: [[Circuit Breaker Remote Open Close>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/Circuit_Breaker_Remote_Open_Close/]] 525 525 526 526 526 + 527 + 527 527 == 1.5 Example 5: SEM Three Energy Meter with RS485-BL or RS485-LN == 528 528 529 529 ... ... @@ -533,17 +533,21 @@ 533 533 * Configure Document for RS485-LN: [[Connect to SEM Three>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/SEM_Three_Energy_Meter/&file=SEM%20three%20and%20Dragino%20RS485-LN%20v1.pdf]] 534 534 535 535 536 -== 1.6 Example 6: CEM C31 485-T1-MID Energy Meter with RS485-LN == 537 537 538 538 539 +== 1.6 Example 6:CEM C31 485-T1-MID Energy Meter with RS485-LN == 540 + 541 + 539 539 This instruction is provided by Xavier Florensa Berenguer from [[NORIA GRUPO DE COMPRAS>>url:http://www.gruponovelec.com/]]. It is to show how to use RS485-LN to connect to CEM C31 485-T1-MID and send the data for remote minitor. The structure is like below: 540 540 541 541 * Configure Document For RS485-LN: [[CEM C31 485-T1-MID>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/Application_Note/ELECTRICAL%20CABINET/&file=ELECTRICAL%20CABINET%20READINGS.pdf||style="background-color: rgb(255, 255, 255);"]] 542 542 543 543 544 -== 1.7 Example 7: Schneider Electric PLC M221 with RS485-BL == 545 545 546 546 549 +== 1.7 Example 7:Schneider Electric PLC M221 with RS485-BL == 550 + 551 + 547 547 [[image:image-20220527094556-31.png]] 548 548 549 549 Network Structure