Content
... ... @@ -61,7 +61,6 @@
61 61  
62 62  
63 63  
64 -
65 65  == **1.3 Example3: Use RS485-LN with energy meters** ==
66 66  
67 67  
... ... @@ -113,12 +113,12 @@
113 113  Connection2
114 114  
115 115  
116 -
117 117  [[image:image-20220527092555-7.png]]
118 118  
119 119  Connection3
120 120  
121 121  
120 +
122 122  === **1.3.2 How to use the parameters of the energy meter and MODBUS commands** ===
123 123  
124 124  
... ... @@ -165,6 +165,7 @@
165 165  RS485-LN provides two configuration methods: AT COMMAND and DOWNLINK.
166 166  
167 167  
167 +
168 168  ==== **1.3.3.1 via AT COMMAND** ====
169 169  
170 170  
... ... @@ -220,7 +220,7 @@
220 220  (((
221 221  (% style="color:blue" %)**Example**:
222 222  
223 -CMD1: Read current data with MODBUS command. address: 0x03 AT+COMMAND1= 01 03 00 03 00 01,1
223 +(% style="color:red" %)**CMD1:**(%%) Read current data with MODBUS command. address: 0x03 AT+COMMAND1= 01 03 00 03 00 01,1
224 224  )))
225 225  
226 226  (((
... ... @@ -234,7 +234,7 @@
234 234  )))
235 235  
236 236  (((
237 -CMD2: Read voltage data with MODBUS command. address: 0x00 AT+COMMAND2= 01 03 00 00 00 01,1
237 +(% style="color:red" %)**CMD2: **(%%)Read voltage data with MODBUS command. address: 0x00 AT+COMMAND2= 01 03 00 00 00 01,1
238 238  )))
239 239  
240 240  (((
... ... @@ -248,7 +248,7 @@
248 248  )))
249 249  
250 250  (((
251 -CMD3: Read total active energy data with MODBUS command. address: 0x0031 AT+COMMAND3= 01 03 00 31 00 02,1
251 +(% style="color:red" %)**CMD3:**(%%) Read total active energy data with MODBUS command. address: 0x0031 AT+COMMAND3= 01 03 00 31 00 02,1
252 252  )))
253 253  
254 254  (((
... ... @@ -276,6 +276,7 @@
276 276  AT COMMAND
277 277  
278 278  
279 +
279 279  ==== **1.3.3.2 via LoRaWAN DOWNLINK** ====
280 280  
281 281  
... ... @@ -301,7 +301,7 @@
301 301  )))
302 302  
303 303  (((
304 -(% style="color:red" %)Note: if user use AT+COMMANDx to add a new command, he also need to send AT+DATACUTx downlink.
305 +(% style="color:red" %)**Note: if user use AT+COMMANDx to add a new command, he also need to send AT+DATACUTx downlink.**
305 305  )))
306 306  
307 307  (((
... ... @@ -375,6 +375,7 @@
375 375  DOWNLINK
376 376  
377 377  
379 +
378 378  === **1.3.4 How to configure and output commands for RS485 to USB** ===
379 379  
380 380  (((
... ... @@ -432,6 +432,7 @@
432 432  USB
433 433  
434 434  
437 +
435 435  === **1.3.5 How to configure multiple devices and modify device addresses** ===
436 436  
437 437  
... ... @@ -462,7 +462,7 @@
462 462  
463 463  (((
464 464  (((
465 -We can use **AT+CFGDEV** to set the device address.
468 +We can use (% style="color:blue" %)**AT+CFGDEV**(%%) to set the device address.
466 466  )))
467 467  )))
468 468  
... ... @@ -506,7 +506,7 @@
506 506  [[image:image-20220601142607-4.png]]
507 507  
508 508  
509 -**PAYLOAD:01 08 DF 43 62**
512 +(% style="color:blue" %)**PAYLOAD: 01 08 DF 43 62**
510 510  
511 511  * 08 DF is the valid value of the meter with device address 02.
512 512  * 43 62 is the valid value of the meter with device address 01.