... ... @@ -37,6 +37,7 @@
37 37  
38 38  
39 39  
40 +
40 40  == **1.2 Example 2: Connect to Pulse Counter** ==
41 41  
42 42  
... ... @@ -113,12 +113,12 @@
113 113  Connection2
114 114  
115 115  
116 -
117 117  [[image:image-20220527092555-7.png]]
118 118  
119 119  Connection3
120 120  
121 121  
122 +
122 122  === **1.3.2 How to use the parameters of the energy meter and MODBUS commands** ===
123 123  
124 124  
... ... @@ -165,6 +165,7 @@
165 165  RS485-LN provides two configuration methods: AT COMMAND and DOWNLINK.
166 166  
167 167  
169 +
168 168  ==== **1.3.3.1 via AT COMMAND** ====
169 169  
170 170  
... ... @@ -220,7 +220,7 @@
220 220  (((
221 221  (% style="color:blue" %)**Example**:
222 222  
223 -CMD1: Read current data with MODBUS command. address: 0x03 AT+COMMAND1= 01 03 00 03 00 01,1
225 +(% style="color:red" %)**CMD1:**(%%) Read current data with MODBUS command. address: 0x03 AT+COMMAND1= 01 03 00 03 00 01,1
224 224  )))
225 225  
226 226  (((
... ... @@ -234,7 +234,7 @@
234 234  )))
235 235  
236 236  (((
237 -CMD2: Read voltage data with MODBUS command. address: 0x00 AT+COMMAND2= 01 03 00 00 00 01,1
239 +(% style="color:red" %)**CMD2: **(%%)Read voltage data with MODBUS command. address: 0x00 AT+COMMAND2= 01 03 00 00 00 01,1
238 238  )))
239 239  
240 240  (((
... ... @@ -248,7 +248,7 @@
248 248  )))
249 249  
250 250  (((
251 -CMD3: Read total active energy data with MODBUS command. address: 0x0031 AT+COMMAND3= 01 03 00 31 00 02,1
253 +(% style="color:red" %)**CMD3:**(%%) Read total active energy data with MODBUS command. address: 0x0031 AT+COMMAND3= 01 03 00 31 00 02,1
252 252  )))
253 253  
254 254  (((
... ... @@ -276,6 +276,7 @@
276 276  AT COMMAND
277 277  
278 278  
281 +
279 279  ==== **1.3.3.2 via LoRaWAN DOWNLINK** ====
280 280  
281 281  
... ... @@ -301,7 +301,7 @@
301 301  )))
302 302  
303 303  (((
304 -(% style="color:red" %)Note: if user use AT+COMMANDx to add a new command, he also need to send AT+DATACUTx downlink.
307 +(% style="color:red" %)**Note: if user use AT+COMMANDx to add a new command, he also need to send AT+DATACUTx downlink.**
305 305  )))
306 306  
307 307  (((
... ... @@ -375,6 +375,7 @@
375 375  DOWNLINK
376 376  
377 377  
381 +
378 378  === **1.3.4 How to configure and output commands for RS485 to USB** ===
379 379  
380 380  (((
... ... @@ -432,6 +432,7 @@
432 432  USB
433 433  
434 434  
439 +
435 435  === **1.3.5 How to configure multiple devices and modify device addresses** ===
436 436  
437 437  
... ... @@ -462,7 +462,7 @@
462 462  
463 463  (((
464 464  (((
465 -We can use **AT+CFGDEV** to set the device address.
470 +We can use (% style="color:blue" %)**AT+CFGDEV**(%%) to set the device address.
466 466  )))
467 467  )))
468 468  
... ... @@ -506,7 +506,7 @@
506 506  [[image:image-20220601142607-4.png]]
507 507  
508 508  
509 -**PAYLOAD:01 08 DF 43 62**
514 +(% style="color:blue" %)**PAYLOAD: 01 08 DF 43 62**
510 510  
511 511  * 08 DF is the valid value of the meter with device address 02.
512 512  * 43 62 is the valid value of the meter with device address 01.
... ... @@ -513,6 +513,7 @@
513 513  
514 514  
515 515  
521 +
516 516  == 1.4 Example 4: Circuit Breaker Remote Open Close ==
517 517  
518 518  
... ... @@ -529,6 +529,7 @@
529 529  
530 530  
531 531  
538 +
532 532  == 1.5 Example 5: SEM Three Energy Meter with RS485-BL or RS485-LN ==
533 533  
534 534  
... ... @@ -539,6 +539,7 @@
539 539  
540 540  
541 541  
549 +
542 542  == 1.6 Example 6: CEM C31 485-T1-MID Energy Meter with RS485-LN ==
543 543  
544 544  
... ... @@ -548,6 +548,7 @@
548 548  
549 549  
550 550  
559 +
551 551  == 1.7 Example 7: Schneider Electric PLC M221 with RS485-BL ==
552 552  
553 553  